Sharp PN-L703B (serv.man3) Service Manual ▷ View online
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 3
2. AGING
1) Display SERVICE MENU 2.
2) Select "AGING" with [VOL + ()], [VOL - (↓)] keys. Press [ENTER] button.
3) Select “AGING1” or “AGING2” with [VOL + ()] [VOL - ()] buttons, and press [ENTER] button. The aging is started.
AGING1: Every time when [BRIGHT + ()] button is pressed, the whole screen color is changed.
AGING2: The whole screen color is changed every 2 sec.
4) When finishing AGING, set this to OFF.
・
AGING1 can be directly executed by pressing the [SIZE] button for about 5 seconds (LED flashes and “F” mark is displayed in the upper
left corner of the screen.) and then pressing the button of [VOL + ()], [VOL - (↓)], [VOL + ()], [VOL - (↓)] sequentially.
・
The power button of the remote controller or the machine cannot terminate aging.
・
With the A model, the controller is shut down automatically after selecting the AGING. When the AGING is selected with other input
screen being displayed, it takes a time to start the AGING.
3. CALIBRATION
Make adjustment of GAIN and OFFSET of A/D converter with Input modes below:
・
ANALOG mode
D-SUB[RGB] terminal
・
COMPONENT mode
D-SUB1[COMPONENT] terminal
・
VIDEO mode
D-SUB1[VIDEO] terminal
1) Switch the Input mode to be adjusted with [INPUT] key.
2) Show the video signal for adjustment on the screen.
<CAUTION>
・
Be sure to make adjustment using the video signal in the table below:
・
By adjusting the DSUB1[RGB], D-SUB2 and WHITEBOARD are also adjusted automatically.
Input Mode
Signal Type
Input Signal Level
(Adjust to standard value)
Signal Timing
Input Image
D-SUB1[RGB]
PC ANALOG signal
RGB level:0.7 Vp-p
1920×1080 60Hz
or XGA(1024x768)
60Hz
or XGA(1024x768)
60Hz
Adjustment image displayed by executing
Adj_uty.exe in CD-ROM supplied with the
product or the image with RGB WHITE
0~255 gradation being indicated.
Adj_uty.exe in CD-ROM supplied with the
product or the image with RGB WHITE
0~255 gradation being indicated.
D-SUB1
[COMPONENT]
[COMPONENT]
COMPONENT
signal
signal
Y level:0.7 Vp-p
(
(
From Pedestal to
White)
Pb/Pr level:0.7 Vp-p
Pb/Pr level:0.7 Vp-p
1080i 60Hz
Full color bar (WHITE100%/ Degree of
Color saturation 100%)
*Recommended signal generator:
ASTRODESIGN Products VG-849,
VG-859
Color saturation 100%)
*Recommended signal generator:
ASTRODESIGN Products VG-849,
VG-859
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 4
D-SUB1
[VIDEO]
[VIDEO]
VIDEO signal
(NTSC3.58)
(NTSC3.58)
0.714 Vp-p
(
(
From Pedestal to
White)
NTSC3.58
Full color bar (WHITE100%/ Degree of
Color saturation 100%)
*Recommended signal generator:
ASTRODESIGN Products VG-849,
VG-859
Color saturation 100%)
*Recommended signal generator:
ASTRODESIGN Products VG-849,
VG-859
3) Display SERVICE MENU 2
4) Select "CALIBRATION" with [VOL + ()], [VOL - (↓)] keys and press [ENTER] key. CALIBRATION screen appears.
5) Select "AUTO CALIBRATION" with [VOL + ()], [VOL - (↓)] keys. Press [ENTER] key.
Calibration is performed and stored in EEPROM.
The adjustment result is displayed on the ADC OFFSET1/ADC OFFSET2/ADC GAIN items.
6) Select "OK" with [VOL + ()], [VOL - (↓)] keys. Press [RETURN] key. CALIBRATION screen is closed.
4. FACTORY RESET
Resets the user adjustment value, USAGE TIME and the Operation log to the factory preset values.
<CAUTION>
*When resetting is made, the operation logs are also deleted. If necessary, save the operation logs before resetting.
1) Display the SERVICE MENU 2.
2) Select "FACTORY RESET" with [VOL + ()], [VOL - (↓)] key, and press [ENTER] key.
3) Select "ON" with [BRIGHT - ( )],[BRIGHT + ()] keys, and press [ENTER] key. "RESETTING" is displayed.
4) Turn the main power switch off and then back on.
(MEMO)
ITEM RESET
ITEMS
FACTORY RESET
Used to reset the all settings to the factory setting.
(
(
It includes USAGE TIME, Operation log, and Error log)
ALL RESET 1
Used to reset the user adjustment values, the usage time, and the operation logs to the factory setting.
(
(
It excepts USAGE TIME, Operation log and Error log)
ALL RESET 2
Used to reset the user setting values except the LAN settings, the communication speed, network settings,
service/support settings and SNMP settings to the factory setting.
(
service/support settings and SNMP settings to the factory setting.
(
It excepts USAGE TIME, Operation log and Error log)
CALIBRATION D-SUB (ANALOG)
AUTO CALIBRATION
ADC OFFSET1
R : 999
B : 999
G : 999
ADC OFFSET2
R : 999
G : 999
B : 999
ADC GAIN
R : 999
G : 999
B : 999
OK
CANCEL
RESET
CALIBRATION SCREEN WHEN PC3/PC4 ANALOG MODE
CALIBRATION COMPONENT (D-SUB)
AUTO CALIBRATION
ADC OFFSET1
Y : 999
Cr : 999
Cb : 999
ADC OFFSET2
Y : 999
Cb : 999
Cr : 999
ADC GAIN
Y : 999
Cb : 999
Cr : 999
OK
CANCEL
RESET
CALIBRATION SCREEN WHEN AV3 COMPONENT MODE
CALIBRATION COMPONENT (D-SUB)
AUTO CALIBRATION
ADC OFFSET1
: 999
ADC OFFSET2
: 999
ADC GAIN
: 999
OK
CANCEL
RESET
CALIBRATION SCREEN WHEN AV5 VIDEO MODE
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 5
5. HARDWARE CHECK
This machine is provided with the function to watch for any abnormality in the hardware.
*When an error occurs in the hardware (internal power voltage), the message of STATUS [XXXX] is displayed.
The power lamp flashes in red. (It differs depending on the setting of " STATUS ALERT" of the FUNCTION.)
*When only a temperature error occurs, the message of "TEMPERATURE" is displayed on the loft lower section of the screen.
The power lamps of red and green flash alternatively. (It differs depending on the setting of "TEMPERATURE ALERT" of the FUNCTION.)
*The error position can be checked. There are following four methods.
5 – 1. METHOD1
1) SERVICE MENU 2 is displayed.
2) Select "HARDWARE CHECK" with [VOL + ()], [VOL - (↓)] keys,
and press [ENTER] key. "HARDWARE CHECK" menu is
displayed.
3) The watch result and the current measurement value of the
hardware are displayed.
Watch result
"OK" or "NG" is displayed.
After turning ON the power, if an
abnormality occurs to be "NG" once, the
"NG" state is kept until the main power is
turned OFF.
After turning ON the power, if an
abnormality occurs to be "NG" once, the
"NG" state is kept until the main power is
turned OFF.
Measurement
value
The measurement value at the time is
displayed when HARDWARE CHECK menu
is displayed.
The measurement value at the time when
an abnormality occurred is saved in the log
data.
displayed when HARDWARE CHECK menu
is displayed.
The measurement value at the time when
an abnormality occurred is saved in the log
data.
The measurement value of the internal voltage displayed is the
A/D conversion value.
The normal range is as shown below.
Item
Default value
SYSTEM POWER1
(OFF)
0 - 255
SYSTEM POWER2
TP 5V
155 - 230
SYSTEM POWER3
SP 13V
90 - 145
SYSTEM POWER4
CTL 13.5V
92 - 145
SYSTEM POWER5
12V2
130 – 190
BACKLIGHT LED
MODULE 0
TOUCH PANEL
TOUCH PANEL
MODULE
MODULE
0
4) For the countermeasures against NG positions.
-> Refer to page "8. THE RED LED FLASHES".
-> Refer to page "9. THE LED LIGHTS UP IN ORDER OF
RED .
5) Press [MENU] key to return to the previous screen, and
terminate the operation.
5 – 2. METHOD2
1) Send "HTST0000" command.
2) Result is returned.
(MEMO)
- Since this model does not monitor SYSTEM POWER3, “OFF” or
“ - ” is displayed.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 6
5 – 3. METHOD3
Check with the “STATUS[XXXX]” number.
1) When an error occurs, four-digit figures are displayed after the
message of “STATUS” on the left lower section of the screen.
They are assigned as follows.
Bit
PN-L703A
0 SYSTEM
POWER1
1 SYSTEM
POWER2
2 SYSTEM
POWER3
3 SYSTEM
POWER4
4 SYSTEM
POWER5
5 BACKLIGHT
6 TOUCH
PANEL
7 - 13
Reserved
14
Temperature sensor abnormality
15 Temperature
abnormality
5 – 4. METHOD4
Check with the item of “STATUS” on the “Product information
(INFORMATION)” screen.
When [DISPLAY] button is pressed, the “INFORMATION” screen
is displayed.
Check with the “STATUS” item on the screen.1) When an error
occurs, four-digit figures are displayed after the message of
“STATUS” on the left lower section of the screen. They are
assigned as follows.
A
Hardware monitoring result
The error detection position is
displayed with the same number
as the “METHOD 3”.
B
The number of controls of
the backlight when a
temperature abnormality
occurs
Displayed in 2 digits.
For more than 99 times, “99” is
displayed.
C
Accumulated control time of
the backlight when a
temperature abnormality
occurs
Displayed in 2 digits.
For more than 99 hours, “99” is
displayed.
D
Number of shifts to the
power standby state when a
temperature abnormality
occurs
Displayed in 2 digits.
For more than 99 times, “99” is
displayed.
E
Reserved
(Not used for this time)
F
Reserved
(Not used for this time)
It takes some time necessary for judgment of a temperature
abnormality and a hardware abnormality as shown below:
- Temperature abnormality:
Min. 2 minutes (Exceeding the threshold value 3 times
continuously in the interval of 1 minute).
- Hardware abnormality:
Min. 18 seconds (Exceeding the threshold value 4 times
continuously in the interval of 6 seconds).
Though, therefore, the threshold value is exceeded on the
“HARDWARE CHECK” screen of SERVICE MANU 2 or in the
periodic send/ test mail, “OK” may be displayed.
In addition, when “NG” judgment is made once, “NG” state is
maintained until the power is turned OFF/ON. Even if, therefore,
the target value is reduced below the threshold value, the
judgment may be “NG” with a normal value.
INFORMATION1
INPUT MODE
SIZE
COLOR MODE
BRIGHT
VOLUME
ID No.
MODEL
S/N
SIZE
COLOR MODE
BRIGHT
VOLUME
ID No.
MODEL
S/N
1920x1080 V:999Hz H:999.9kHz
STATUS
XXXX-XXXX-XXXX-XXXX
TOUCH PANEL
LAN