DOWNLOAD Sharp PN-60TB3 (serv.man6) Service Manual ↓ Size: 4.72 MB | Pages: 56 in PDF or view online for FREE

Model
PN-60TB3 (serv.man6)
Pages
56
Size
4.72 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Monitor / (Setup Manual)
File
pn-60tb3-sm6.pdf
Date

Sharp PN-60TB3 (serv.man6) User Manual / Operation Manual ▷ View online

ENGLISH
7
E
Turning Power On/Off
Caution
•  Turn on the monitor first before turning on the computer or 
playback device.
•  To keep the performance of the WHITEBOARD stable, put 
the monitor in the Power off (Standby mode) state once a 
day.
Turning on the main power
Main power switch
The monitor enters the Power off (Standby mode) state.
Caution
•  The main power must be turned on/off with the main power 
switch. Do not connect/disconnect the power cord or turn 
the breaker on/off while the main power switch is on.
•  When switching the main power switch or the POWER 
button off and back on, always wait for at least 5 seconds.
•  For a complete electrical disconnection, pull out the main 
plug.
•  Before switching off the main power switch, always put the 
monitor in the Power off (Standby mode) state. (Hold down 
the POWER button until the exit screen appears.)
Turning power on
1.  Press the POWER button.
POWER button / Power LED
Status
Status of the monitor
Green lit
Power on
Orange lit
Power off (Standby mode)
Orange flashing
Power off  
(Whiteboard standby mode)
Green flashing
Input signal waiting mode
•  The WHITEBOARD appears. 
  (Factory setting. Can be changed in START INPUT MODE 
in the SETUP menu.)
8
E
n
Operation mode
When the monitor is turned on for the first time after being 
shipped from the factory, the operation mode setting screen 
will be displayed. Set it to MODE1 or MODE2.
MODE1 ... OFF IF NO OPERATION is set to ON, and 
STANDBY MODE is set to LOW POWER. (These 
settings can not be changed.)
Determines whether or not to set the monitor to go 
into standby mode when there is no operation from 
the remote control unit, or LAN for over 4 hours.  
Power consumption in standby mode is also 
minimized.
MODE2 ... Will perform standard operation.
OFF IF NO OPERATION is set to OFF, and 
STANDBY MODE is set to STANDARD. These 
settings can be changed.
Even after being set, changes can be made using 
OPERATION MODE, located in the menu of the monitor. (See 
Operation manual.)
n
Date/time setting
•  If the time has yet to be set when the monitor is first turned 
on, the date/time setting screen appears. Set the date and 
time.
DATE/TIME SETTING 
/
/
OK···[ENTER]   CANCEL···[RETURN]
:
   
:
01
01
14
/
00
00
:
/ 20
1.  Press 
 or 
 to select the date and time, and 
press 
 or 
 to change the numerical values. 
2.  Press 
ENTER
 .
•  Be sure to set the date and time.
•  The date/time setting screen will close automatically if 
no operation is performed for about 15 seconds. The 
date and time can be set using DATE/TIME SETTING 
from the SETUP menu when the date/time setting screen 
disappears.
TIPS
• 
Set the date in “Day/Month/Year” order.
• 
Set the time on a 24-hour basis.
• 
The clock is maintained by the internal battery.
• 
If you already set the time but the date/time setting 
screen appears when the power is turned on, the 
internal battery may be exhausted. Please contact 
your local SHARP servicing dealer or service center for 
assistance with battery replacement.
• 
Estimated service life of the internal battery: About 5 
years (depending on monitor operation)
• 
The initial battery was inserted at the factory when the 
monitor was shipped, so it may run out of power before 
its expected operation life.
Turning Power On/Off (Continued)
9
E
ENGLISH
Calibration
Calibration is used to perform position alignment so that the 
mouse cursor moves to the correct position when the screen 
is touched.
Before initial use, perform calibration.
1.  Set the input to WHITEBOARD.
2.  Touch the launch button.
Launch button
The launcher appears.
3.  Touch [Setting].
You will be prompted to enter a password.
4.  Enter the password and touch [OK].
  Enter the password set in the Admin Password. If a 
password is not set, enter “00000”.
5.  Touch [Admin Settings] and [Calibration].
6.  Follow the instructions on the screen to perform 
calibration.
TIPS
•  If you will be using the touch panel with a computer, 
perform calibration from the Touch Panel Settings Tool. 
For details, see the Touch Panel Settings Tool Operation 
Manual.
Turning power off
The power can be turned off in the following ways.
(1) Press the POWER button.
  The monitor enters whiteboard standby mode.  
This method allows faster startup and shutdown than (2), 
however, more power is consumed while in standby mode.
(2) Hold down the POWER button until the exit screen 
appears.
  The monitor enters standby mode. The WHITEBOARD is 
in the shutdown state. More time is required for shutdown 
and startup than (1), however, less power is consumed in 
standby mode. 
Before switching off the main power switch, always put the 
monitor in the Power off (Standby mode) state.
Caution
•  When the power is turned off, any data on the WHITEBOARD 
is lost. If there is unsaved data, a message will appear prior 
to shutdown. Save the data.
•  If the monitor will be turned off by SCHEDULE, LAN 
control, or OFF IF NO OPERATION, save any data you 
need in advance. The power will turn off even if there is 
unsaved data. (The data will be lost.)
•  When turning the monitor power on again, wait at least 5 
seconds after shutdown is completed.
•  Do not disconnect the power cord, open the breaker, 
or switch off the main power switch before shutdown is 
finished. Risk of failure.
Turning Power On/Off (Continued)
10
E
Mounting Precautions (For SHARP dealers and service engineers)
•  When installing, removing or moving the monitor, ensure that this is carried out by at least 4 people.
•  Be sure to use a wall-mount bracket designed or designated for mounting the monitor.
•  This monitor is designed to be installed on a concrete wall or pillar. Reinforced work might be necessary for some materials 
such as plaster / thin plastic board / wood before starting installation. 
This monitor and bracket must be installed on a wall which can endure at least 4 times or more the weight of the monitor. 
Install by the most suitable method for the material and the structure.
•  To attach a VESA-compliant mounting bracket, use M6 screws that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the 
thickness of the mounting bracket.
•  Do not use an impact driver.
•  After mounting, please carefully ensure the monitor is secure, and not able to come loose from the wall or mount.
•  Do not use any screw holes other than VESA holes for installation.
n
Attaching the Tray
Secure the tray using 5 tray mounting screws (M3) (supplied).
Page of 56
Display

Click on the first or last page to see other PN-60TB3 (serv.man6) service manuals if exist.