SYMPTOM
Food being overcooked to an unacceptable condition using SensNcook.
CAUSE
Humidity sensor inoperative and therefore failing to detect the humidity level within the
cavity.
cavity.
AH sensor assembly (Ref. 1-25) connection to the CPU unit via the connector CN-F
has been intermittent.
has been intermittent.
ACTION
Replace the connector CN-F with the part number below.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
---
3 pin connector
QCNCMA237DRE0
AB