R-334 - 1
SHARP CORPORATION
SERVICE MANUAL
R
R-334 (W)
R-334 (W)F
S60198R334EHW
TABLE OF CONTENTS
                                                                                                                                                                 Page
CAUTION.......................................................................................................................................................2
WARNING/GENERAL IMPORTANT INFORMATION................................................................................... 3
SERVICING.................................................................................................................................................. 4
PRODUCT DESCRIPTION............................................................................................................................7
APPEARANCE VIEW.....................................................................................................................................8
OPERATION SEQUENCE.............................................................................................................................9
FUNCTION OF IMPORTANT COMPONENTS.............................................................................................10
TROUBLESHOOTING GUIDE......................................................................................................................12
TEST PROCEDURE......................................................................................................................................14
DESCRIPTION OF LSI..................................................................................................................................21
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE........................................................ .24
MICROWAVE MEASUREMENT...................................................................................................................28
WIRING/REWIRING......................................................................................................................................29
TEST DATA AT A GLANCE..........................................................................................................................29
SCHEMATIC DIAGRAMS.............................................................................................................................30
PICTORIAL DIAGRAM..................................................................................................................................31
CONTROL PANEL CIRCUITDIAGRAM........................................................................................................32
PRINTED WIRING BOARD DIAGRAM.........................................................................................................33
PARTS LIST..................................................................................................................................................34
EXPLODED DIAGRAM OF OVEN PARTS...................................................................................................37
CONTROL PANEL PARTS/DOOR PARTS................................................................................................. .38
MISCELLANEOUS/PACKING & ACCESSORIES....................................................................................... .39
COOK & DEFROST
R-334
In interests of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
MICROWAVE OVEN
MODELS
R-334 - 2
CAUTION
MICROWAVE RADIATION
Personnel should not be exposed to the mircowave energy which may radiate from the magnetron or
other microwave generating devices if it is improperly used or connected.  All input and output micro-
wave connections, waveguides, flanges and gaskets must be secured.  Never operate the device with-
out a microwave energy absorbing load attached.
Never look into an open waveguide or antenna while the device is energised.
VARNING
MIKROVAGSSTRALING
Personal får inte utsättas för mikrovågsenergi som kan utstrala från magnetronen eller andre
mikrovågsalstrande anordningar om dessa är felanslutna eller används på fel sätt.  Alla in-och
utgångsanslutningar för mikrovågor, vagledare, flänsar och packningar måste vara fast anslutna.
Mikrovågsgeneratorn får inte arbeta utan att absorberande belastning är ansluten.  Titta aldrig in i en
öppen vågledare eller antenn när mikrovågsgeneratorn är påkopplad eller laddad.
VAROITUS
MIKROAALTOSATEILYA
Käyttäjä ei saa joutua alttiiksi mikroaaltoenergialle, jota voi säteillä magnetronista tai muusta
mikroaaltoja kehittävästä laitteesta, jos sitä käytetään väärin tai jos se kytketään väärin.  Kaikkien
mikroaaltoliitäntöjen sekä syöttö-että ulostulopuolella, aaltoputkien laippojen ja tiivisteiden tulee olla
varmistettuja.
Mikroaaltouunia ei koskaan saa käyttää ilman kuormaa jossa mikroaaltoenergiaa kuluu.  Avoimeen
aaltoputkeen tai antenniin ei koskaan saa katsoa virran ollessa kytkettynä.
ADVARSEL
MIKRØBOLGESTRÅLING
Personell må ikke utsettes for mikrobølge-energi som kan utstråles fra magnetronen eller andre
mikrobølge-generende deler dersom apparatet feilbetjenes eller blir feiltikoplet.  Alle inn-og ut-
tilkoplinger i forbindelse med mikrobølge-strålingen, bølgeledere, flenser og tetningsringer/pakninger må
festes ordentlig.
Aldri bruk apparatet med mindre en mikrobålge-absorberende last er plassert i ovnsrommet.  Aldri se
direkte inn i en åpen bølgeleder eller antenne imens apparatet er strømførende.
ADVARSEL
MIKRØBOLGEBESTRALING
Man bør ikke udsætte sig for mikrobølgebestråling fra magnetronen eller andre
mikrobølgefrembringende anordninger, hvilket kan ske hvis apparatet er forkert tilsluttet eller bruges
forkert.  Alle mikrobølgeindgange og-udgange, bølgeledere, flanger og tætningsstrimler må være
forsvarligt udført.
Anvend aldrig ovnen uden en mikrobølgeabsorberende anordning.  Se aldrig ind i en åben bølgeleder
eller antenne, mens ovnen er i brug.
CAUTION
R-334 - 3
R-334 (W), R-334(W)F
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
Engineers with Operation and Service Information.
It is recommended that Service Engineers carefully study the
entire text of this manual, so they will be qualified to render
satisfactory customer service.
SERVICE MANUAL
Note:                 The parts marked "*" are used at voltage
more than 250V. (Parts List)
Anm:
Delar märket med "*" har en spänning
överstigande 250V.
Huom:
Huolto-ohjeeseen merkitty.  "tähdella" osat
 joissa jännite on yli 250V.
Bemerk:
Deler som er merket "asterisk" er utsatt for
spenninger over 250V til jord.
Bemærk:
Dele mærket med stjerne benyttes med
 hojere spænding end 250 volt.
WARNING
SHARP CORPORATION
OSAKA, JAPAN
WARNING
Never operate the oven until the following points are ensured.
(A) The door is tightly closed.
(B) The door brackets and hinges are not defective.
(C) The door packing is not damaged.
(D) The door is not deformed or warped.
(E) There is not any other visible damage with the oven.
Servicing and repair work must be carried out only by trained
Service Engineers.
All the parts marked “ * ” on parts list are used at voltages more
than 250V.
Removal of the outer wrap gives access to potentials above
250V.
All the parts marked “ 
 ” on the parts list may cause undue
microwave exposure, by themselves, or when they are
damaged, loosened or removed.
MICROWAVE OVEN
SERVICING
PRODUCT SPECIFICATIONS
GENERAL INFORMATION
APPEARANCE VIEW
OPERATING SEQUENCE
FUNCTION OF IMPORTANT
COMPONENTS
TROUBLESHOOTING GUIDE
AND TEST PROCEDURE
TOUCH CONTROL PANEL
COMPONENT REPLACEMENT
AND ADJUSTMENT PROCEDURE
MICROWAVE MEASUREMENT
WIRING DIAGRAM
PARTS LIST
R-334 - 4
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge high voltage capacitor.
WARNING AGAINST THE CHARGE OF THE HIGH-
VOLTAGE CAPACITOR
The high-voltage capacitor remains charged about 60
seconds after the oven has been switched off. Wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is, of the connecting lead of
the high-voltage rectifier) against the chassis with the
use of an insulated screwdriver.
WARNING TO SERVICE PERSONNEL
Sharp recommend that wherever possible fault-finding is
carried out with the supply disconnected. It may in, some
cases, be necessary to connect the supply after the outer
case has been removed, in this event carry out 3D checks
and then disconnect the leads to the primary of the power
transformer. Ensure that these leads remain isolated from
other components and the oven chassis. (Use insulation
tape if necessary.) When the testing is completed carry out
3D checks and reconnect the leads to the primary of the
power transformer.
REMEMBER TO CHECK 4R
1) Reconnect all leads removed from components during
testing.
2) Replace the outer case (cabinet).
3) Reconnect the supply.
4) Run  the oven. Check all functions.
Microwave ovens should not be run empty. To test for the
presence of microwave energy within a cavity, place a cup
of cold water on the oven turntable, close the door and set
the power to HIGH and set the microwave timer for two (2)
minutes. When the two minutes has elapsed (timer at zero)
carefully check that the water is now hot. If the water remains
cold carry out 3D checks and re-examine the connections to
the component being tested.
When all service work is completed, and the oven is fully
assembled, the microwave power output should be checked
and a microwave leakage test carried out.
NL
VERGEET DE VOLGENDE 3 STAPPEN NIET
1)
Haal de stekker uit het stopcontact.
2)
Open de deur en zorg ervoor dat hij niet dicht kan
vallen.
3)
Ontlaad de hoogspanningscondensator.
PAS OP VOOR DE ELECTRISCHE LADING VAN
DE HOOGSPANNINGSCONDENSATOR
De hoogspanningscondensator blijft nog ongeveer
60 seconden lang opgeladen, nadat de oven is
uitgeschakeld. Wacht 60 seconden voordat u de
verbinding van de hoogspannings-condensator
(m.a.w. de verbindingsdraad van de
hoogspanningsgelijkrichter) met een geïsoleerde
schroevedraaier kortsluit tegen het chassis.
Sharp beveelt ten sterkste aan dat, voor zover mogelijk,
defecten worden opgespoord wanneer de stekker uit het
stopcontact is gehaald. Soms is het nodig om de
stroomtoevoer weer tot stand te brengen nadat de
buitenmantel verwijderd is. Herhaal dan de
bovengenoemde 3 stappen en haal de electrische draden
uit de primaire zijde van de vermogenstransformator.
Zorg ervoor dat deze draden geïsoleerd blijven van
andere elementen en van het chassis van de oven.
(Gebruik zo nodig isolatieband.) Wanneer de test is
uitgevoerd, herhaalt u de bovenstaande 3 stappen en
verbindt u de electrische draden weer aan de primaire
zijde van de vermogenstransformator.
VERGEET DE VOLGENDE 4 STAPPEN NIET
1)
Sluit de draden weer aan diezijn losgehaald voor
de test.
2)
Plaats de buitenmantel weer om het toestel heen
(kabinet).
3)
Stop de stekker weer in het stopcontact.
4)
Zet de oven aan. Controleer alle functies.
Magnetronovens mogen niet leeg aangezet worden. Om te
controleren of er microgolf-energie binnen de oven wordt
geproduceerd, plaatst u een mok met koud water op de
draaitafel van de oven, sluit de deur, zet de oven op HIGH en
stelt de klok van de magnetron in op twee (2) minuten.
Wanneer de twee minuten voorbij zijn (klok staat op nul),
controleert u voorzichtig of het water heet is. Indien het water
nog steeds koud is, herhaalt u de allereerste drie stappen en
controleer nogmaals de aansluitingen naar de geteste
onderdelen.
Wanneer alle reparaties zijn uitgevoerd en de oven weer in
elkaar is gezet, moet de het magnetronvermogen worden
gecontroleerd en moet worden gecontroleerd of er geen
microgolflekkage is.
SERVICING
   GB Microwave ovens contain circuitry capable of producing very high voltage and current.
Contact with the following parts will result in electrocution
High voltage capacitor, High Voltage transformer, Magnetron, High voltage rectifier assembly, High voltage wires.
Magnetronovens bevatten circuits die een zeer hoge spanning en stroom kunnen voortbrengen. Contact met de
volgende onderdelen kan elektrocutie tot gevolg hebben.
Hoogspanningscondensator, hoogspanningstransformator, magnetron, hoogspanningsgelijkrichter, hoogspannings
draden.
Page of 40
Display

Sharp R-334 (serv.man4) Service Manual ▷ Download

  • DOWNLOAD Sharp R-334 (serv.man4) Service Manual ↓ Size: 529.45 KB | Pages: 40 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp R-334 (serv.man4) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp R-334 (serv.man4) Microwave Oven. Information contained in Sharp R-334 (serv.man4) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.