R-209(SL)
R-209(W)
11
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
In this service manual, troubleshooting by unit replacement is described according to the symptoms
indicated.
Control unit.
The following symptoms indicate a defective control unit.
a) When rotating the potentiometer, the power level can not be selected.
b) Cooking is not possible.
M
RELAY TEST
CARRY OUT 3D CHECKS.
Remove the outer case and check voltage between Pin No. 3 of the 2 pin connector (A) and the
common terminal of the relay RY1 on the control unit with an A.C. voltmeter.
The meter should indicate 230 - 240 volts, if not check oven circuit.
Relay Test
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated .......... Defective relay.
DC. voltage not indicated .... Check diode which is connected to the relay coil. If diode is good,
control unit is defective.
RELAY SYMBOL
OPERATIONAL VOLTAGE
CONNECTED COMPONENTS
RY1
Approx. 12.0V D.C.
Oven lamp / Turntable motor / Fan motor
RY2
Approx. 11.0V D.C.
High voltage transformer
CARRY OUT 4R CHECKS.
To protect the electronic circuits, this model is provided with a fine foil pattern added to the input circuit
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
1
The rated voltage is not applied between Pin
Check supply voltage and oven power cord.
No. 3 of the 2 pin connector (A) and the
common terminal of the relay RY1.
2
Only pattern at “a” is broken.
*Insert jumper wire J1 and solder.
3
Pattern at “a” and “b” are broken.
*Insert the coil RCILF2003YAZZ between “c” and “d”.
NOTE: *At the time of making these repairs, make
a visual inspection of the varistor. Check
for burned damage. If any abnormal con-
dition is detected, replace the defective
control unit.
CARRY OUT 4R CHECKS.
N
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING
BOARD (PWB) IS OPEN
D71
R75
(F1)
(J2)
D1
(J1)
a
b
c
d
D70
R-209(SL)
R-209(W)
12
The control unit consists of the following circuits as shown in the control unit circuit.
The principal functions of these circuits and their related signals are explained below.
Control Unit
Control unit consists of LSI, reset circuit, power source circuit, relay circuit and synchronizing signal circuit.
1) Reset Circuit
This circuit generates a signal which resets the LSI to the initial state when power is supplied.
2)  Potentiometer Circuit
The circuit makes setting of the power level by variable resistance.
3) Power Source Circuit
This circuit generates voltage necessary in the control unit from the AC line voltage. In addition, the synchronizing
signal is available in order to compose a basic standard time in the clock circuit.
Symbol
Voltage
Application
VDD
+5V
LSI(IC-1)
VSS
0V
LSI(IC-1)
4) Relay Circuit
To drive the magnetron, fan motor, turntable motor and  light the oven lamp.
5) Synchronizing Signal Circuit
The power source synchronizing signal is available in order to compose a basic standard time in the clock circuit. It
accompanies a very small error because it works on commercial frequency.
CONTROL UNIT ASSEMBLY
OUTLINE OF CONTROL UNIT
R-209(SL)
R-209(W)
13
DESCRIPTION OF LSI
The I/O signal of the LSI are detailed in the following table.
Pin No.
Signal
I/O
Description
1
VDD
IN
Power source voltage: 5V.
Connected to 5V.
2
VSS
IN
Power source voltage: 0V.
Connected to 0V.
3
XIN
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is generated by connecting the capacitor and resistor to
XIN.
4
XOUT
OUT
Terminal not used.
5
CNVSS
IN
Connected to VSS through resistor.
6
RESET
IN
Auto clear terminal.
Signal is inputted to reset the LSI to the initial state when power is supplied.
7
AIN1
IN
Signal coming from potentiometer.
Voltage from potentiometer is converted into the power level by the A/D converter built
into the LSI.
8
AIN0
IN
Cooking start detection terminal.
When “H” level is inputted to AIN0, cooking starts.
9
D3
OUT
Signal to allow Magnetron high-voltage circuit to be drived.
While the signal (Sqrare Waveform) is generating
from D3, the Magnetron high-voltage circuit is al-
lowed to be drived.
10
D2
OUT
Signal to check the model.
11
D1
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY1). The signal
holds “L” level during microwave cooking and “H”
level while not cooking. In other cooking modes
(70%, 50%, 30%, 10%) the signal turns to “H” level
and “L” level in repetition according to the power
level.
12
D0
OUT
Terminal not used.
13
INT
IN
Signal to synchronize LSI with commercial power source frequency.
This is basic timing for all real time processing of LSI.
14-16
P12-P10
OUT
Terminal not used.
17-20
P03-P00
IN
Terminal to change the Models and functions.
ON/OFF time ratio in Mi-
cro cooking
(a. 32second time base)
MICRO
ON
OFF
COOK
100%
32sec.
0sec.
70%
24sec.
8sec.
50%
18sec.
14sec.
30%
12sec.
20sec.
10%
6sec.
26sec.
20 msec
H : 5V
L : 0V
20 msec
During cooking
H
L
R-209(SL)
R-209(W)
14
1. Precautions for Handling Electronic Components
This unit uses CMOS LSI in the integral part of the
circuits. When handling these parts, the following pre-
cautions should be strictly followed. CMOS LSI have
extremely high impedance at its input and output
terminals. For this reason, it is easily influenced by the
surrounding high voltage power source, static electric-
ity charge in clothes, etc., and sometimes it is not fully
protected by the built-in protection circuit.
In order to protect CMOS LSI.
1) When storing and transporting, thoroughly wrap
them in aluminium foil. Also wrap PW boards con-
taining them in aluminium foil.
2) When soldering, ground the technician as shown in
the figure and use grounded soldering iron and
work table.
2. Servicing of Touch Control Panel
We describe the procedures to permit servicing of the
touch control panel of the microwave oven and the
precautions you must take when doing so.
To perform the servicing, power to the touch control
panel is available either from the power line of the oven
itself or from an external power source.
(1) Servicing the touch control panel with power
supply of the oven :
CAUTION:
THE HIGH VOLTAGE TRANSFORMER OF THE
MICROWAVE OVEN IS STILL LIVE DURING
SERVICING AND PRESENTS A HAZARD .
Therefore, when checking the performance of the
touch control panel, put the outer cabinet on the
oven to avoid touching the high voltage trans-
former, or unplug the primary terminal (connector)
of the high voltage transformer to turn it off; the end
of such connector must be insulated with an insulat-
ing tape. After servicing, be sure to replace the
leads to their original locations.
A. On some models, the power supply cord be-
tween the touch control panel and the oven itself
is so short that the two can't be separated.
For those models, check and repair all the
controls (sensor-related ones included) of the
touch control panel while keeping it  connected
to the oven.
B. On some models, the power supply cord be-
tween the touch control panel and the oven
proper is so long enough that they may be
separated from each other. For those models,
therefore, it is possible to check and repair the
controls of the touch control panel while keeping
it apart from the oven proper; in this case you
must short both ends of the door sensing switch
(on PWB) of the touch control panel with a
jumper, which brings about an operational state
that is equivalent to the oven door being closed.
SERVICING
As for the sensor-related controls of the touch
control panel, checking them is possible if the
dummy resistor(s) with resistance equal to that
of the controls are used.
(2) Servicing the touch control panel with power
supply from an external power source:
Disconnect the touch control panel completely from
the oven proper, and short both ends of the door
sensing switch (on PWB) of the touch control panel,
which brings about an operational state that is
equivalent to the oven door being closed. Connect
an external power source to the power input termi-
nal of the touch control panel, then it is possible to
check and repair the controls of the touch control
panel; it is also possible to check the sensor-related
controls of the touch control panel by using the
dummy resistor(s).
3. Servicing Tools
Tools required to service the touch control panel as-
sembly.
1) Soldering iron: 30W
(It is recommended to use a soldering iron with a
grounding terminal.)
2) Oscilloscope: Single beam, frequency range: DC -
10MHz type or more advanced model.
3) Others: Hand tools
4. Other Precautions
1) Before turning on the power source of the control
unit, remove the aluminium foil applied for prevent-
ing static electricity.
2) Connect the connector of the key unit to the control
unit being sure that the lead wires are not twisted.
3) After aluminium foil is removed, be careful that
abnormal voltage due to static electricity etc. is not
applied to the input or output terminals.
4) Attach connectors, electrolytic capacitors, etc. to
PWB, making sure that all connections are tight.
5) Be sure to use specified components where high
precision is required.
approx. 1M ohm
Page of 32