Sharp UP-3515 (serv.man13) Driver / Update ▷ View online
Page 2 - 6
1.
>>> CHANGES / IMPROVEMENTS / CORRECTIONS <<<....................................................................................3
2.
WRONG CALCULATION IN CASE OF ITEMDISCOUNT. ............................................................................................3
3.
WRONG KP PRINT AFTER ITEM VOID IN RELATION TO SIDEABLE/CONDIMENT REGISTRATION..............................3
4.
MISSING ITEMS BY DOWNLOAD OF CUSTOMER SALES REPORT WITH ONLINE FUNCTION. ..................................3
5.
DRAWER ALARM DOES NOT WORK AT THE SATELLITE. ..........................................................................................3
6.
PRINTING OF TAX EVEN THE TAX AMOUNT IS 0. .....................................................................................................3
7.
CALCULATION METHOD IN CASE OF GRANTING MIXED PROMOTION, E.G. MIX&MATCH AND SBTL%..............3
8.
ERROR “LACKING MEMORY” OCCUR DURING A CLERK SIGNON..........................................................................3
9.
REGISTRATION OF DIFFERENT PLUTYPE COMBINATIONS TOGETHER WITH SIDEABLEPLU. ..................................4
10.
BILL SEPARATION IN COMBINATION WITH ITEM SPLIT.............................................................................................4
11.
CCD ERROR AT TIMEOUT OF EMPLOYEE.................................................................................................................5
12.
SECURED REPORTS. ...................................................................................................................................................5
13.
SECURED REPORTS IN INLINESYSTEM. .....................................................................................................................5
14.
SECURED REPORTS WITH A FOLDER NAME LENGTH OF 8 CHARACTERS. ..............................................................5
15.
ONLINE FUNCTION (CLERK ZREPORT) IN RELATION TO THE ECR STATUS. .............................................................6
16.
LEAVING THE DIAGNOSTIC MODE MAY RESULT IN AN ERROR. ..............................................................................6
17.
STACKED REPORTS. ...................................................................................................................................................6
Page 3 - 6
Important note:
The ROM version V1.52 is based on V1.51, but it is not compatible (neither Data nor Language Text
Resources) with this ROM version.
1.
>>> Changes / Improvements / Corrections <<<
2.
Wrong calculation in case of ItemDiscount.
If an ItemDiscount has been granted, it could happen that the discount was calculated from the
Subtotal, but not from that Item for which the discount has been given for. This has been
corrected.
Subtotal, but not from that Item for which the discount has been given for. This has been
corrected.
3.
Wrong KP print after Item Void in relation to Sideable/Condiment registration.
In case of an Indirect Item Void after a mixed registration with Sideable, Condiment and Tied
Condiment PLU’s, the KP print of the articles were not correct. With this version, the print out is
correct.
Condiment PLU’s, the KP print of the articles were not correct. With this version, the print out is
correct.
4.
Missing Items by download of Customer Sales Report with Online function.
After the Customer Sales Report has been cleared either by OnlineRJE or by
\3 X2/Z2 MODE\2 RESETTING\13 CUSTOMER SALES 2 some new registrations have been charged
to one/several Customer(s). At the previous ROM Version, it could happen, that by reading the
CUSTOMER SALES report by Online RJE the registered items are missing. This has been corrected.
\3 X2/Z2 MODE\2 RESETTING\13 CUSTOMER SALES 2 some new registrations have been charged
to one/several Customer(s). At the previous ROM Version, it could happen, that by reading the
CUSTOMER SALES report by Online RJE the registered items are missing. This has been corrected.
5.
Drawer alarm does not work at the Satellite.
If the SRV parameter #990A (open drawer at TimeOut of last Employee) is set to YES, a set drawer
alarm will not occur at the Satellite. This has been corrected.
alarm will not occur at the Satellite. This has been corrected.
6.
Printing of TAX even the TAX amount is 0.
If by SRV #905B the ‘TAX printing when TAX is 0’ is set to PRINT, the TAX amount were not printed
by mistake. This is corrected.
by mistake. This is corrected.
7.
Calculation method in case of granting mixed promotion, e.g. Mix&Match and SBTL%.
In case of granting mixed promotion, the SBTL% promotion discount was calculated from the gross
amount. By this version, the SBTL% promotion discount will be calculated from the already by the
Mix&Match discount reduced amount. This conforms to the specification of Version 1.50.
amount. By this version, the SBTL% promotion discount will be calculated from the already by the
Mix&Match discount reduced amount. This conforms to the specification of Version 1.50.
8.
Error “LACKING MEMORY” occur during a Clerk SignOn.
If a Clerk tries to make a SignOn at a Satellite while there is an active online communication via the
RS232 port of the Master with a PC, the error “LACKING MEMORY” may occur. At this version,
the SignOn at the Satellite will not result in an error, even there is an active online communication
between the Master and a PC.
RS232 port of the Master with a PC, the error “LACKING MEMORY” may occur. At this version,
the SignOn at the Satellite will not result in an error, even there is an active online communication
between the Master and a PC.
Page 4 - 6
9.
Registration of different PLUType combinations together with SideablePLU.
With ROM Version V1.30 the SIDEABLE PLU type has been introduced. Even the registration of
SIDEABLE PLU’s in combination with other types of PLU (e.g. LINK, COMBO, CONDIMENT) underlay
to certain restrictions, they were possible sometimes. This could result in wrong print out of the
registration. In the following, we summarize such restrictions and add the new ones which are
introduced with this new ROM Version.
Neither a “SIDE” nor a “SIDE W.ROLLUP” PLU can be registered individually. They are belonging
to a “SIDEABLE” PLU, but it is possible to assign them to a Link or Combo PLU. In such kind of
registration, they will be treated as normal articles.
Even a “SIDEABLE” PLU can be part of a Condiment, Link or Combo PLU, they will be registered
as a normal article. It will loose its SIDEABLE property. It is neither possible to register a “SIDE” nor
a “SIDE W.ROLLUP” after such a registration.
After the registration of a “SIDEABLE” PLU, up to 30 SIDE PLU types/Free Texts which should
belong to this leading PLU can be registered.
A registration of a “SIDE” or a “SIDE W.ROLLUP” PLU after a SIDEABLE PLU registration which is a
CondimentTied is not possible.
A Sideable PLU may have a Condiment Link.
Following registration is possible:
Sideable PLU with Condiment Link
Condiment Tied(s)
Side(s) or SideRU(s)
If the Sideable PLU will be voided, all of the Condiment Tied(s), Side(s) and SideRU(s) will be voided
as well.
The Sideable PLU with all of its Side(s)/SideRU(s) must belong to the same PLU Group (SortGroup).
A CondimentTied can be a Sideable, but if such a Condiment Tied is registered, it will loose its
Sideable property.
Side/SideRU must not be a LeadingCondiment (must not have a Condiment Link).
Side/SideRU must not be a CondimentTied.
Side/SideRU must not be a LeadingLink or LeadingCombo PLU.
A LinkTied or ComboTied should not be a Sideable, Side or SideRU. If such a Tied is registered, it
will loose its Side property.
SIDEABLE PLU’s in combination with other types of PLU (e.g. LINK, COMBO, CONDIMENT) underlay
to certain restrictions, they were possible sometimes. This could result in wrong print out of the
registration. In the following, we summarize such restrictions and add the new ones which are
introduced with this new ROM Version.
Neither a “SIDE” nor a “SIDE W.ROLLUP” PLU can be registered individually. They are belonging
to a “SIDEABLE” PLU, but it is possible to assign them to a Link or Combo PLU. In such kind of
registration, they will be treated as normal articles.
Even a “SIDEABLE” PLU can be part of a Condiment, Link or Combo PLU, they will be registered
as a normal article. It will loose its SIDEABLE property. It is neither possible to register a “SIDE” nor
a “SIDE W.ROLLUP” after such a registration.
After the registration of a “SIDEABLE” PLU, up to 30 SIDE PLU types/Free Texts which should
belong to this leading PLU can be registered.
A registration of a “SIDE” or a “SIDE W.ROLLUP” PLU after a SIDEABLE PLU registration which is a
CondimentTied is not possible.
A Sideable PLU may have a Condiment Link.
Following registration is possible:
Sideable PLU with Condiment Link
Condiment Tied(s)
Side(s) or SideRU(s)
If the Sideable PLU will be voided, all of the Condiment Tied(s), Side(s) and SideRU(s) will be voided
as well.
The Sideable PLU with all of its Side(s)/SideRU(s) must belong to the same PLU Group (SortGroup).
A CondimentTied can be a Sideable, but if such a Condiment Tied is registered, it will loose its
Sideable property.
Side/SideRU must not be a LeadingCondiment (must not have a Condiment Link).
Side/SideRU must not be a CondimentTied.
Side/SideRU must not be a LeadingLink or LeadingCombo PLU.
A LinkTied or ComboTied should not be a Sideable, Side or SideRU. If such a Tied is registered, it
will loose its Side property.
10.
Bill Separation in combination with item split.
If an item is split during the Bill Separation operation (a bottle of wine for two people), it was
possible that a zero amount for the split items were transferred to the target GLU. With this
version, the correct amount for the items will be split.
possible that a zero amount for the split items were transferred to the target GLU. With this
version, the correct amount for the items will be split.
Page 5 - 6
11.
CCD error at TimeOut of Employee.
Following setting have been made at the ECR:
‘Employee working time entry’ is set to COMPULSORY (SRV #987A).
‘Automatic Clerk SignOn after TimeIn/BreakOut’ and ‘Automatic Clerk SignOff after TimeOut’ and
‘Employee and Clerk relationship is removed (i.e. Clerk Z is done)’ is set to YES (SRV #987B).
‘Terminal CCD’ is set to YES (SRV #988D).
Under some circumstances, i.e. after a Service Reset, the TimeOut operation of an Employee after
the GeneralZ report has been carried out will result in the error ‘CCD NOT DONE’, even the CCD
entry has been made. This error is corrected at this version.
‘Employee working time entry’ is set to COMPULSORY (SRV #987A).
‘Automatic Clerk SignOn after TimeIn/BreakOut’ and ‘Automatic Clerk SignOff after TimeOut’ and
‘Employee and Clerk relationship is removed (i.e. Clerk Z is done)’ is set to YES (SRV #987B).
‘Terminal CCD’ is set to YES (SRV #988D).
Under some circumstances, i.e. after a Service Reset, the TimeOut operation of an Employee after
the GeneralZ report has been carried out will result in the error ‘CCD NOT DONE’, even the CCD
entry has been made. This error is corrected at this version.
12.
Secured Reports.
During the execution of “Secured Reports”, the data of the following files were saved and cleared
automatically:
Hourly, Employee Transaction, GT, Customer Sales, CCD Shift, Employee Time, Open GLU,
Z Counter, Closed Transaction, Entry Mask files (Universal 120), TLOG and Electronic Journal.
Unfortunately, for “Employee Time” and “Entry Mask files” the data were not cleared, even they
have been saved successfully onto SD Card. By using the new ROM Version also these data are
cleared.
automatically:
Hourly, Employee Transaction, GT, Customer Sales, CCD Shift, Employee Time, Open GLU,
Z Counter, Closed Transaction, Entry Mask files (Universal 120), TLOG and Electronic Journal.
Unfortunately, for “Employee Time” and “Entry Mask files” the data were not cleared, even they
have been saved successfully onto SD Card. By using the new ROM Version also these data are
cleared.
13.
Secured Reports in InlineSystem.
Because the reports in an InlineSystem will be taken at the Master, the “Secured Reports” feature
introduced at V1.50, is advisable at the Master only. The “Secured Reports” feature was not
available at the Satellite.
Beside of the main function of the “Secured Reports” feature, it is also possible to get i.e. the
Electronic Journal data saved onto the SD Card. Due to it is not possible to receive and store the
Electronic Journal data from a Satellite at Master side, the “Secured Reports” feature is now
available at the Satellite as well.
If the “Secured Reports” feature is enabled at the Satellite it will save the Electronic Journal data
and the All RAM Backup respectively the PGM Backup according to their PGM setting onto the
local SD Card.
Furthermore the function key “EOD_READY_CHECK” is also enabled at the Satellite in order to
check if the machine is in a status that the “Secured Reports” can be carried out.
In case of an Inline System with a BackupMaster while the BackupMaster has taken over the role
of the Master (due to Master down), the BackupMaster still behaves like the Satellite. Only the
Electronic Journal as well as PGM Backup and ALL RAM Backup, according to their setting, will be
saved on SD Card.
introduced at V1.50, is advisable at the Master only. The “Secured Reports” feature was not
available at the Satellite.
Beside of the main function of the “Secured Reports” feature, it is also possible to get i.e. the
Electronic Journal data saved onto the SD Card. Due to it is not possible to receive and store the
Electronic Journal data from a Satellite at Master side, the “Secured Reports” feature is now
available at the Satellite as well.
If the “Secured Reports” feature is enabled at the Satellite it will save the Electronic Journal data
and the All RAM Backup respectively the PGM Backup according to their PGM setting onto the
local SD Card.
Furthermore the function key “EOD_READY_CHECK” is also enabled at the Satellite in order to
check if the machine is in a status that the “Secured Reports” can be carried out.
In case of an Inline System with a BackupMaster while the BackupMaster has taken over the role
of the Master (due to Master down), the BackupMaster still behaves like the Satellite. Only the
Electronic Journal as well as PGM Backup and ALL RAM Backup, according to their setting, will be
saved on SD Card.
14.
Secured Reports with a folder name length of 8 characters.
If a folder name consists out of 8 characters, it will not be taken over correctly sometimes. With this
version, the given folder name will be set correctly although it has the max. of 8 characters.
version, the given folder name will be set correctly although it has the max. of 8 characters.
Display