Sharp UP-3300 (serv.man18) Service Manual ▷ View online

PROGRAMMING MANUAL
CODE: 00ZUP3300VPME
POS TERMINAL
MODEL 
UP-3300
(For "V" version)
SHARP CORPORATION
CHAPTER 1. PROGRAM RESET and SRV mode . . . . . . . . . . . . . . . . . . . . . . .1
CHAPTER 2. MASTER RESET (All Memory Clear) . . . . . . . . . . . . . . . . . . . . . .2
CHAPTER 3. READING OF SRV MODE PROGRAM  . . . . . . . . . . . . . . . . . . . .4
CHAPTER 4. SRV MODE PROGRAMMING ("2 SETTING") . . . . . . . . . . . . . . .9
CHAPTER 5. SRV MODE PROGRAMMING ("3 IRC SETTING")  . . . . . . . . . .48
*
For setting in USER PROGRAMMING mode, refer to the Reference Manual
which is Provided with each UP-3300.
CONTENTS
CHAPTER1. PROGRAM RESET
and SRV mode
In the UP-3300, the following reset switch (location No: S1) is used to
switch to the service (SRV) mode and to reset.
PROGRAM RESET
Used to return the machine back to its operation state after a lock up
has occured.
PROCEDURE
1) Turn off the AC switch.
2) Set the reset switch to "ON" position.
3) Turn on the AC switch.
4) Set the reset switch to "OFF" position.
5) The reset menu windowis displayed as shown below.
DISPLAY:
Touch the [PROGRAM RESET] key.
6) PROGRAM RESET is started.
7) After completion of the program reset, the SRV mode is displayed
as shown below.
DISPLAY:
[SRV mode screen]
Please select
PROGRAM RESET
MASTER RESET
– 1 –
CHAPTER 2. MASTER  RESET
(All Memory Clear)
There are three possible methods to perform a master reset.
1. MRS-1 (Master resetting 1): Clear the
entire memory and resumes initial
values.
PROCEDURE
  1) Turn off the AC switch.
  2) Set the reset switch to "ON" position.
  3) Turn on the AC switch.
  4) Set the reset switch to "OFF" position.
  5) The reset menu window is displayed as shown below.
DISPLAY:
Touch the [MASTER RESET] key.
  6) The master reset menu window is displayed as shown below.
DISPLAY:
Touch the [MASTER RESET] key.
  7) The secret number input window is displayed as shown below.
DISPLAY:
Enter the secret number for the MASTER RESET-1 and touch
the [ENTER] key.
Secret number for MRS-1: 11111111
  8) MASTER RESET-1 is started.
DISPLAY:
  9) After completion of the master reset, the buzzer sounds three
times and the following SRV mode display is shown.
DISPLAY:
[SRV mode screen]
2. MRS-2 (Master resetting 2): Clear the
entire memory and resumes initial
values.
The keyboard must be entered by hand. This reset is used if an
application needs different keyboard layout other than that supplied
by a normal MRS-1.
PROCEDURE
  1) Turn off the AC switch.
  2) Set the reset switch to "ON" position.
  3) Turn on the AC switch.
  4) Set the reset switch to "OFF" position.
  5) The reset menu window is displayed as shown below.
DISPLAY:
Touch the [MASTER RESET] key.
Please select
PROGRAM RESET
MASTER RESET
Please select
MASTER  RESET
MASTER  RESET  2
ENTER PASSWORD
ENTER
CLEAR
0
1
4
7
00
2
5
8
CANCEL
3
6
9
MASTER RESET
Please select
PROGRAM RESET
MASTER RESET
– 2 –
  6) The master reset menu window is displayed as shown below.
DISPLAY:
Touch the [MASTER RESET 2] key.
  7) The secret number input window is displayed as shown below.
DISPLAY:
Enter the secret number for the MASTER RESET-2 and touch
the [ENTER] key.
Secret number for MRS-2: 22222222
  8) Set the fixed keys in the table below (Start from the [HOME] key,
The key are displayed sequentially)
DISPLAY:
No.
KEY NAME
1
HOME
2
CANCEL
3
CL
4
MODE
5
UP  ( 
 )
6
DOWN  ( 
 )
  9) MASTER RESET-2 is started.
DISPLAY:
10) After completion of the master reset, the buzzer sounds three
times and the following SRV mode display is shown.
DISPLAY:
[SRV mode screen]
Please select
MASTER  RESET
MASTER  RESET  2
ENTER PASSWORD
ENTER
CLEAR
0
1
4
7
00
2
5
8
CANCEL
3
6
9
ENTER HOME
MASTER RESET
– 3 –
Page of 50
Display

Sharp UP-3300 (serv.man18) Service Manual ▷ Download

  • DOWNLOAD Sharp UP-3300 (serv.man18) Service Manual ↓ Size: 1.07 MB | Pages: 50 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp UP-3300 (serv.man18) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp UP-3300 (serv.man18) EPOS. Information contained in Sharp UP-3300 (serv.man18) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.