DOWNLOAD Sharp UP-3300 (serv.man17) Service Manual ↓ Size: 852.32 KB | Pages: 14 in PDF or view online for FREE

Model
UP-3300 (serv.man17)
Pages
14
Size
852.32 KB
Type
PDF
Document
Service Manual
Brand
Device
EPOS / Option Installation Manual
File
up-3300-sm17.pdf
Date

Sharp UP-3300 (serv.man17) Service Manual ▷ View online

CODE: 00ZUP3300VIME 
POS TERMINAL 
MODEL
 UP-3300 
("V" version) 
SHARP CORPORATION
Parts marked with "
!
" is important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.
  1. Removing the Rear display filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
  2. Replacing the Rear display filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
  3. Removing the Top cabinet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
  4. Replacing the Top cabinet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
  5. Removing the Power transformer, NF PWB and AC cord  . . . . . . . . . . . . . . . . . . .3
  6. Replacing the Power transformer, NF PWB and AC cord  . . . . . . . . . . . . . . . . . . .3
  7. Removing the LCD unit   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
  8. Replacing the LCD unit   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
  9. PS-RAM DISK : UP-P02MB2   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
10. RS232 I/F: ER-A7RS & EFT I/F ER-02EF  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
11. MCR UNIT: UP-E12MR2  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
12. DRAWER BOX UNIT: ER-03DW/04DW/05DW  . . . . . . . . . . . . . . . . . . . . . . . . . . .6
13. REMOTE DISPLAY: UP-P16DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
14. HOW TO EXTEND DISPLAY POLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
15. BUILT-IN PRINTER: UP-T80BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
16. SRN I/F: STANDARD  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
17. RS232 I/F: STANDARD  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
CONTENTS
Precautions
Before installation, be sure to turn off the power.
Use gloves to protect your hand from being cut by the angle
and the chassis.
Connect all the cables securely. When connecting or
disconnecting the cables, be careful not to apply stress to the
cables. (It may cause disconnection.)
Ground the human body to prevent against troubles and dust
adhesion to the LCD by static electricity. When assembling the
LCD, use a discharge blower to prevent against dust intrusion.
Be careful to the high voltage of the invertor PWB transformer.
Install the ferrite core onto the specified position of the cable
securely.
Conditions for soldering circuit parts
To solder the following parts manually, follow the conditions
described below.
PARTS
NAME
PARTS CODE
LOCATION
CONDITIONS FOR
SOLDERING
Ceramic
oscillator
RCRMZ7002RCZZ
MAIN PWB: 
  X1 
(8M)
270°/3sec.
RCRMZ7004RCZZ
MAIN PWB: 
    X2 (7.37M)
270°/3sec.
Note for handling of Touch panel
The transparency of the touch panel should be vitally important.
Do not put finger prints or water print on the surface. Use clean
finger such or gloves and masks.
For handling, do not hold the transparent area, and do not hold the
heat seal connector section to assure reliability. 
Do not overlay touch panels. The edge may damage the surface. 
Do not put a heavy thing on the touch panel.
Do not apply a strong shock, and do not drop it. 
When attaching the protection film again, carefully check for no
dirt. If there is any dirt, it is transferred. 
To clean dirt on the surface, use dry, soft cloth or a cloth immersed
in ethyl alcohol.
Check that the housing does not give stress to the touch panel. 
Be careful not to touch the touch panel with tools. 
The heat seal section is easily disconnected. Be careful not to give
a stress to the heat seal section when installing. 
The touch panel is provided with an air groove to make the exter-
nal and the internal air pressure equal to each other. If water or oil
is put around the air groove, it may penetrate inside. Be careful to
keep the air groove away from water and oil. 
Input is performed with fingers. Do not use a hard thing for input-
ting. 
Note for handling of LCD
The LCD elements are made of glass. BE careful not to give them
strong mechanical shock, or they may be broken. Use extreme
care not to break them.
If the LCD element is broken and the liquid is leaked, do not lick it.
If the liquid is attached to your skin or cloth, immediately clean with
soap. 
Use the unit under the rated conditions to prevent against damage.
Be careful not to drop water or other liquid on the display surface.
The reflection plate and the polarizing plate are easily scratched.
BE careful not to touch them with a hard thing such as glass,
tweezers. Never hit, push, or rub the surface with hard things.
When installing the unit, be careful not to apply stress to the LCD
module. If an excessive stress is applied, abnormal display or
uneven color may result. 
Cautions on handling connectors
When connecting or disconnecting the following connectors, follow
the procedures below.
1)
PARTS NAME
PARTS CODE
LOCATION
FFC
CONNECTOR
QCNCW7207RC4J
MAIN PWB: CN6
TOUCH PWB: CN5
How to Connect or Disconnect FFC
(1)
Open the slider to unlock position
The slider will open only up to a fixed height (about 1.2mm). If
you forcibly pull up the slider further, it may be dropped.
(2)
Insert the FFC
Insert the FFC firmly untill the FFC hits the bottom of the
connector’s insulator.
(3)
Close the slider to lock position
Insert the FFC and then push the slider downward.
Slider
1.2mm
UNLOCK
FFC
FFC
CONNECTOR
FFC
CONNECTOR
FFC
CONNECTOR
FFC
Slider
LOCK
– 1 –
2)
PARTS NAME
PARTS CODE
LOCATION
FFC
CONNECTOR
QCNCW7217RC3J
TOUCH
PWB: CN1
How to Insert FFC
(1)
Open the slider to unlock position
Open the slider upwards up to an angle of 60 degrees. If the
slider does not fully open, the FFC can not be smoothly inserted.
(2)
Insert the FFC
Insert the FFC firmly until the FFC hits the bottom of the
connector’s insulator.
(3)
Close the slider to lock position
Insert the FFC and then push the slider downward.
(4)
To pull out the FFC, unlock the slider to pull it out in the same
procedures as (1).
1. Removing the Rear display filter
1) Remove the two Screws 
1
.
2) Remove the Rear display filter 
2
.
2. Replacing the Rear display filter
Install the Rear display filter in the reverse order of removing.
FFC
FFC
CONNECTOR
FFC
CONNECTOR
FFC
CONNECTOR
FFC
FFC
– 2 –
3. Removing the Top cabinet
1) Remove the two Screws 
1
.
2) Remove the Side cabinet 
7
.
2) Remove the Screw 
2
.
3) Remove the Printer cover 
3
.
4) Remove the Screw 
4
.
5) Remove the Top cabinet 
8
.
a) Lift the top cabinet and put it straight in the direction of arrow
A. ( Be careful not to pull the cable between the LCD I/F PWB
of the top cabinet and the MAIN PWB of the Bottom cabinet.)
b) Pull and remove the following cables between the LCD I/F
PWB of the top cabinet and the MAIN PWB of the Bottom
cabinet.
LCD Cable 
5
 : MAIN PWB : CN6
Earth wire 
6
4. Replacing the Top cabinet
Install the top cabinet in the reverse order of removing. Before install-
ing, make sure that each connector is connected securely.
5. Removing the Power transformer,
NF PWB and AC cord
1) Remove the Power transformer 
1
.
a) Remove the four Screws 
2
.
b) Remove the two Connectors 
3
.
2) Remove the NF PWB 
4
.
a) Remove the four Screws 
5
.
b) Remove the two Screws 
6
 and the three Earth wire 
7
.
c) Remove the NF angle unit 
8
.
d) Remove the Screw 
9
.
3) Remove the AC cord 
F
.
a) Use a minus screwdriver to loosen the AC cord fixing screws
(2 pcs.) of the NF PWB  
4
 unit.
b) Remove the two screws 
G
.
c) Remove the AC cord cover 
H
.
d) Remove the AC cord 
F
 from the NF PWB 
4
.
6. Replacing the Power transformer,
NF PWB and AC cord
Install the in the Power transformer, NF PWB and AC cord in the
reverse order of removing.
Before installing, make sure that each connector is connected securely.
*
When connecting the AC cord to the power supply unit in
assembly, tighten with the torque of 3 kg/cm 
±
 1 kg/cm.
1
A
2
1
7
8
4
6
3
5
– 3 –
Page of 14
Display

Sharp UP-3300 (serv.man17) Service Manual ▷ Download

  • DOWNLOAD Sharp UP-3300 (serv.man17) Service Manual ↓ Size: 852.32 KB | Pages: 14 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp UP-3300 (serv.man17) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp UP-3300 (serv.man17) EPOS. Information contained in Sharp UP-3300 (serv.man17) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.