Brand
Device
EPOS / Sales Support
File
er-a770-sm3.pdf
Date

Sharp ER-A770 (serv.man3) Handy Guide ▷ View online

13
RE-CALL GLU.
This feature was developed for the European market.
The feature will enable a GLU to be finalised through the Cash
method and then re-called if necessary.
Set up procedure
The FINAL key has to be set up as TOTAL STATUS
1.  Service Line 981-C = +2
2.  Assign the Final Key to the Keyboard.
3.  Assign the Re-call TTL  key (code 114) to the Keyboard.
Operational procedure
The GLU would be finalised by pressing the FINAL key.
The GLU code will now appear to be finalised, that is if the same
GLU code is re entered it will operate as normal i.e. the GLU will
have no items against it and it will have a zero balance.
However in the above example, if the Re-call key is pressed after
the GLU code the GLU contents will re-appear, the operator can
now treat this GLU as normal.
DETAILED DESCRIPTIONS
14
INTERMEDIATE GLU FINALISE CHECK
This feature prohibits the operator from finalising a GLU without
first taking an Intermediate Bill reading.
Set up procedure
To force Intermediate Bill print before cashing off set as follows
Select PGM2 Mode
Select Setting
Select Optional
Select Function Prohibit
Set the Intermediate Bill Finalise to Disable
Operational procedure
After the above settings have been carried out the operator will not
be allowed to finalise a GLU unless an Intermediate Bill has been
taken since the last items were entered.
DETAILED DESCRIPTIONS
15
GLU Changes.
The description for the GLU # text has increased to 12 characters.
The operation of the GLU system has changed in order to make it
more flexible.
There is no requirement for the NC key. The GLU key is now used
to open a new GLU or open an existing GLU.
If the ERA770 is set to Auto Generation of the next GLU code
(919-B) the depression of the GLU key whilst a GLU is open will
have the Affect of New Balancing the current GLU and opening a
new GLU.
The GLU key is now used to open a new GLU or open an existing
GLU.
If the ERA770 is set to Auto Generation of the next GLU code
(919-B) the depression of the GLU key whilst a GLU is open will
have the Affect of New Balancing the current GLU and opening a
new GLU.
DETAILED DESCRIPTIONS
ELECTRONIC JOURNAL
The feature is similar to that of the UP3300.
16
You can select the journal to be recorded in memory and later
print the details out on roll or display the details.
There are 3 categories: -
1. By Consecutive Number
2. By Date
3. By Clerk
The journal details can be printed out as a report by selecting 1 or
more of these categories.
When the Electronic Journal becomes full and your machine is set
to continue operation the oldest items are overwritten. (Same as
ER-A220).
Set up procedure
1.  Ensure that the Electronic Journal file has been created.
2.  Set up Journal Printer as E.J File
3.  To use as “wrap around” set when E.J. is full continue.
Select PGM2 Mode
Select Setting
Select Optional
Select Function Selecting
Set  “When E.J. is Full to Continue”
Operational procedure
Enter into X1/Z1 Mode and take E.Journal Report.
NETWORK CONFIGURATIONON
STANDARD MEMORY
.
The ERA770 comes with standard 1 Meg of RAM.