First, turn on the machines in the IRC system and put them in the PGM2 mode.  The
programming procedures for both the master and satellites will be explained below.
It is necessary to assign machine numbers to the master and satellites before the IRC
programming.
1.
Select “PGM2 MODE” from the mode selection window
and press the key to enter the PGM2 mode.
2.
Select “SETTING” and press the key.
3.
Select “REGISTER” and press the key. The
REGISTER window will open.
Select “MACHINE#” from the REGISTER window and
press the key. 
4.
Enter a machine number and press the key. 
Machine number: up to 6 digits (0–999999) 
5.
Repeat steps 1 to 4 for all machines in the IRC system.
In an IRC network, each machine number must be unique.
Do not use the same number for more than one machine.
NOTE
ENTER
ENTER
ENTER
ENTER
ENTER
IRC Programming
1
1. Setting the machine numbers – master and satellite
 *ER-A750  97.4.1 3:57 PM  Page 4
5
1.
Enter the PGM2 mode.
2.
Select “INLINE SETTING” and press the
key.
3.
Enter a terminal number (0–254) and press the 
key.
(For programming for BMA MACHINE No., SYSTEM
RETRY and T-LOG FULL, see pages 8–10.)
4.
Repeat steps 1 to 3 for all machines in the IRC system.
• Terminal numbers must be assigned to the master and each satellite in the IRC system.
(For setting the master’s terminal number, see the next paragraph.)
• If an inline network contains two or more machines with the same terminal number, inline
communications will not be achieved correctly. Each terminal number must be unique. 
• The terminal number should be within the range from 1 to 254.
• If the terminal number “000” is programmed for a machine, it is put in the OFF LINE mode and
cannot take part in inline communications.
NOTE
ENTER
ENTER
2. Setting the terminal numbers (IRC machine numbers) – 
master and satellite
 *ER-A750  97.4.1 3:57 PM  Page 5
6
(1) Creating the master list (subwindow program)
1.
Enter the PGM2 mode.
2.
Select “INLINE SETTING” and press the
key.
3.
Enter a terminal number (0–254) for the master, carry
out the programming for other INLINE SETTING items
and press the
key. The subwindow for the creation
of the master list will open. 
(For programming for BMA MACHINE No., SYSTEM
RETRY and T-LOG FULL, see pages 8–10.)
4.
Enter the terminal number (1–254) and press the
key. The subwindow for machine number entry will
open. 
5.
Enter the machine number (1–999999) of a machine in
the IRC system and press the
key.
6.
Repeat steps 4 to 5 for all machines in the IRC
system. Press the
key to complete the master list.
TL
ENTER
ENTER
ENTER
ENTER
3. Creating/updating the master list – master
 *ER-A750  97.4.1 3:57 PM  Page 6
7
• The terminal numbers and machine numbers of the master and satellites must be entered into
the master list for inline communications.
• The terminal numbers and machine numbers of up to 16 machines (one master and 15
satellites) can be entered into the master list.
• The terminal number should be within the range from 1 to 254 and the machine number from 1
to 999999.
• No satellite can perform inline communications unless its terminal and machine numbers are
present in the master list.
• If a machine number which already exists in the master list is entered, a lock error will occur
even when the corresponding terminal number does not exist in the list.
(2) Deleting a machine from the master list (subwindow program)
To delete a terminal number from the master list, proceed as follows:
1.
Select “PGM2 MODE” from the mode selection window and press the
key to enter
the PGM2 mode.
2.
Select “INLINE SETTING” and press the
key. The INLINE SETTING window will
open. 
3.
Press the
key. The subwindow for the master list will open.
4.
Enter the terminal no. to be deleted and press the
key.
5.
The machine will ask you as follows: “ARE YOU SURE?” If you are sure to delete it,
select “YES”. If not, select “NO”.
• You can delete any of the terminal numbers that are in the master list.
NOTE
DEL
TL
ENTER
ENTER
NOTE
 *ER-A750  97.4.1 3:57 PM  Page 7
Page of 77
Display

Click on the first or last page to see other ER-A750 (serv.man7) service manuals if exist.