Sharp XE-A207 (serv.man2) Service Manual ▷ View online

XE-A207/A217/A307   LEAD-FREE SOLDER
■  LEAD-FREE SOLDER
The PWB’ s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The
alphabet following the LF mark shows the kind of lead-free solder. 
Example:
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident. 
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is rec-
ommendable. 
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is inferior to
conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive tem-
perature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed. 
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.  
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after com-
pletion of soldering work. 
If the soldering iron tip is discolored black during soldering work, clean
and file the tip with steel wool or a fine filer. 
5mm
Lead-Free
Solder composition 
code (Refer to the 
table at the right.)
<Solder composition code of lead-free solder> 
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
CAUTIONS
THERE IS A RISK OF EXPLOSION IF THE BATTERY
IS REPLACED BY AN INCORRECT TYPE.
PROPERLY DISPOSE OF USED BATTERIES ACCORDING 
TO THE INSTRUCTIONS.
CAUTIONS
n
Risk of explosion if battery is replaced by an incorrect type.
Dispose of batteries according to the instructions.
n
Do not leave the unit with the battery discharged for more than one month. 
It will shorten the battery life. 
If the unit is left unused for a long period, be sure to charge the battery fully. 
Also note that the battery must be charged periodically (once a month) because it will discharge naturally. 
XE-A207/A217/A307
MASTER RESET
– 1 –
CHAPTER 1. MASTER RESET
This programming is chiefly performed when the ECR is shipped, installed, or serviced.
1. MASTER RESET
Master resetting clears the entire memory and resumes initial values.
Initial values of language can be selected one from following 5 kinds.
• 1 English
• 2 German
• 3 French
• 4 Spanish
• 5 Swedish
Master resetting can be accomplished by using the following “Proce-
dure 1” or “Procedure 2”.
PROCEDURE 1
1) Unplug the AC cord from the wall outlet.
2) Remove 2 dry batteries and wait for 1 minute.
3) Plug in the AC cord to the wall outlet.
4) Language selection menu is displayed. Push the corresponding
number key.
5) Set current date/time and push [TL/NS] key.
6) Set tax rate and push [TL/NS] key.
7) Set mode pass code and push [TL/NS] key.
8) Set manager pass code and push [TL/NS] key.
9) Set logo message and push [TL/NS] key.
10) REG mode screen is displayed.
11) Insert 2 dry batteries.
PROCEDURE 2
1) Unplug the AC cord from the wall outlet.
2) Push [receipt paper feed] key and [CL] key.
3) Plug in the AC cord to the wall outlet during the depression of above
2 keys.
4) Language selection menu is displayed. Push the corresponding
number key.
5) Set current date/time and push [TL/NS] key.
NO BATTERY
XE-A207/A217/A307
MASTER RESET
– 2 –
6) Set tax rate and push [TL/NS] key.
7) Set mode pass code and push [TL/NS] key.
8) Set manager pass code and push [TL/NS] key.
9) Set logo message and push [TL/NS] key.
10) REG mode screen is displayed.
2. PROGRAM RESET
Program resetting resumes the initial program without clearing memory.
This operation must be performed with batteries loaded.
1) Unplug the AC cord from the wall outlet.
2) Push [receipt paper feed] key and [0] key.
3) Plug in the AC cord to the wall outlet during the depression of above
2 keys.
4) MODE menu screen is displayed.
XE-A207/A217/A307
PGM MODE
– 3 –
CHAPTER 2. PGM MODE
1. MAJOR KEYS USED IN THE PGM MODE
1-1. BASIC OPERATION KEY
1-2. TEXT INPUT MODE
KEY
NAME
Action
2
CURSOR UP
Move cursor to up (1 character)
4
CURSOR DOWN
Move cursor to down (1 character)
3
CURSOR RIGHT
Move cursor to right (1 character)
1
CURSOR LEFT
Move cursor to left (1 character)
2
PAGE UP
Move cursor to up (1 page)
4
PAGE DOWN
Move cursor to down (1 page)
DEL
DELETE
Delete (Delete 1 record)
CL
CLEAR
Clear numeric entry or error message
CANCEL
CANCEL
Operation cancel & back to previous menu
TL
ALL ENTER
All entry terminate
ST
SELECTABLE VALUE LIST
•  Show the selectable value list
•  Select item and hide the list (only toggle list)
• (DECIMAL POINT) TOGGLE SELECT
Selection switching (On the entry item and selectable value list)
NEXT
NEXT RECORD
Move to the same item of the next record. In case of detail setting of DEPT/PLU/EAN can be
used. If next record does not be exist, display is back to previous menu.
PREV.
PREVIOUS RECORD
Move to the same item of the previous record. Same as NEXT RECORD operation.
KEY
Action
DEL
Delete (Delete 1 character)
DC
Change character entry mode <Double/Normal>
SHIFT
Change character entry mode <Capital/Small>
CAPS
Change CAPS mode <CAPS ON/OFF>
00
Character code entry
• (DECIMAL POINT)
Reverse rotation (for Multi tapping entry)
TEXT
Change character mode (for Multi tapping entry)
Page of 54
Display

Sharp XE-A207 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sharp XE-A207 (serv.man2) Service Manual ↓ Size: 659.65 KB | Pages: 54 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XE-A207 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XE-A207 (serv.man2) ECR. Information contained in Sharp XE-A207 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.