DOWNLOAD Sharp XE-A107 (serv.man2) Service Manual ↓ Size: 983.04 KB | Pages: 28 in PDF or view online for FREE

Model
XE-A107 (serv.man2)
Pages
28
Size
983.04 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / XE-A107 Service Manual
File
xe-a107-sm2.pdf
Date

Sharp XE-A107 (serv.man2) Service Manual ▷ View online

 
4-2 
 
 
2.  Block diagram 
1)  XE-A147 / XE-A137 
 
 
2)  XE-A107 
 
 
 
4-3   
 
3.  Description 
1) DISPLAY 
The display of these models is LED type. And there are 2 types 
such as 8 digits and 9 digits. It is depend on the destination of 
models. 
 
 
 
 
a.  Display content 
Display   
Departments/PLU Code: 
The department code or PLU code entered appears on the left. 
For example, if the key for department 1 is pressed, "1" would 
appear in the extreme left position. 
 
Repeat: 
Indicates the number of times the same department key is 
pressed. If an entry is repeated more than ten times, only the 
first digit is displayed (12 displays as "2"). 
(
) Error: 
This symbol appears, accompanied by a warning beep, when an 
error is made. If this occurs during a transaction because of an 
excessive digit entry, simply press [CL] and re-enter correctly. 
(
) Program: 
This symbol Appears on the display when the cash register is 
being programmed in the Z/PGM mode. 
(
) Finalization: 
This symbol appears when a transaction is finalized by pressing 
[CA/ AT/NS], [CH] or [CHK].     
(
) Subtotal: 
This symbol appears when [#/SBTL] is pressed and the cash 
register computes the subtotal, and also when the amount 
tendered is less than the total sale amount. 
(
) Change: 
This symbol appears whenever the change due amount is 
displayed. 
 
( ) Exchange: 
   This symbol appears when [EX] is pressed to calculate a subtotal 
in foreign currency
   
 
 
(
) Low battery: 
This symbol appears when the power of the installed batteries is 
below a certain level or you need  to replace the batteries with 
new ones. (see the "Maintenance" section for explanation.) 
(
 
) No battery: 
This symbol appears when no batteries are installed, or the 
installed batteries are empty.
 
 
 
In addition, the following appear when appropriate: 
The minus sign (-) can appear in positions 2 to 8. 
The decimal point appears in positions 1 to 3. 
When entry of the secret code is necessary, "---" appears in   
positions 1 to 4. 
 
2)  KEYBOARD AND MODE SW 
a.  Keyboard layout (ex XE-A107) 
 
b.  Key list 
Key top 
Description 
0-9, 00 
Numeric keys 
↑ 
Paper feed key 
X
/TM 
Multiplication / Time key 
CL 
Clear key 
   
Void key 
ESC 
Escape / help key 
Percent key 
PO 
Paid out key 
RA/VAT  
Received on account / VAT key 
SHIFT 
Department shift key 
PLU 
PLU (Price Look Up) key   
DEPT 1-4 (5-8) 
Department 1-4 (5 -8) key 
CR 
Credit key 
EX 
Exchange key 
CH 
Check key 
#/ST 
Non add / Subtotal 
TL/AT/NS 
Total / Amount tendered / No sale key 
 
 
4-4   
 
Mode switch layout 
 
 
 
c.  Function 
 
Turns the display off. No operations are possible   
REG 
Permit transaction entry 
 
Permit correction after final a transaction 
X/Flash 
Permits printing of sales reports and display the 
flash reports 
Z/PGM 
Permits printing and resetting of sales reports and 
programming 
 
3)  BATTERY 
a.  MEMORY BACK UP BATTERY 
For memory back up, the dry battery ULM-3 (3 pieces) are 
needed. 
1. 
Memory holding time: 
Approx. 1 year after New dry batteries are installed. 
(It is depend on the battery capacity) 
2. 
Battery exchange method: 
When the low battery symbol "L" lights up, replace the 
batteries (3 AA) replaced by the following method; 
1)   Power on the ECR. 
2)   Mode switch turn to "REG" mode. 
3)   Remove the OLD dry batteries (3 pieces). 
4)   The no-battery symbol "
L
" light up. 
5)   Insert the NEW dry batteries (3 pieces). 
6)    Confirm the low battery symbol "L" and no-battery 
symbol "
L
" is off. 
 
b.  LOW BATTERY 
Low battery indication will appear on the left side of display when 
the battery voltage is low. 
CASE 1: When sitting idle or after completion of transaction. The 
machine can indicate the low battery condition (Always) 
CASE 2: Low battery indication will not appear during key 
operations, but will appear after power up of the cash 
register. 
[Display sample] 
“0.00”:    Battery is OK.   
"L 0.00": Low battery (The batteries have to be replaced.) 
After finalization 
"F 12.34": Battery is OK.   
"L 12.34": Low battery ("L" indicate instead of "F".) 
c.  NO BATTERY 
If the user forgets to replace the battery and the battery voltage 
falls below a certain level, or if a power failure occurs with no 
batteries installed, the memory contents cannot be retained. The 
CPU judges it as no battery and performs the master reset. In this 
case, all the settings and registrations are cleared. If, however, the 
power is continuously supplied to the AC cord, the memory 
contents are retained. 
Low battery:   
Batteries are installed, but the voltage is 
low. Memory back up can be done. 
No battery:    Batteries are not installed or the voltage is extremely 
low. The master reset is executed when a power 
failure occurs, when the batteries are not properly 
changed. 
Low battery & No battery indication will appear at the most left 
position of display when the battery voltage is low. 
CASE 1:    When any numeric entry & item entry is not done or 
just after 
finalization. 
The machine can indicate the battery condition. (Always) 
CASE 2: When numeric entry or item entry is done. 
Battery condition is not appeared. 
Exceptionally, at the power is restored after power failure, 
the low battery & No battery indication will appear on the 
display only when the battery voltage is low. 
And the indication will disappear after any key entry. 
[Display sample] 
"      0.00" : Battery is OK. 
"L 0.00" : Low battery 
"
L
 0.00" : No battery   
After finalization 
"F 12.34": Battery is OK. 
"L 12.34": Low battery ("L" indicate instead of "F".) 
"
L
 12.34": No battery ("L" indicate instead of "F" 
 
 
 
5-1 
 
CHAPTER 5. DIAGNOSTICS 
1.  XE-A137/XE-A147 
1)  Diagnostic menu 
 
DIAG menu 
DESCRIPTION 
1  Mode switch test 
To check the mode key function 
2  Key test 
Keyboard check 
3  Display test 
To check a display 
4  Drawer test 
To check a drawer opening 
5  Printer test 
Printer test 
6  Printer paper sensor test  To check a printer paper sensor 
7  AD conversion level test  AD conversion check 
8  CLOCK test 
To check the clock on CPU 
Destination display / 
ROM version 
To check the Destination setting and 
ROM version 
10  SD card test 
To check the SD-card write protection 
11  RS232C (XE-A147 only)  To execute the loopback test 
12  ROM (Japan only) 
To check the ROM for Japanese 
characters 
13  RAM 
To execute the RAM read write test 
 
2)  Entering procedure 
It is possible to enter the DIAG mode with following procedure;   
1. 
To set the mode switch to Z/PGM position 
2. 
To input the job code in accordance with below list 
3. 
To push the PO key 
4. 
Start the Diagnostic mode 
 
DIAG menu 
Mode key 
position 
Key code 
Mode switch test 
Z/PGM 
‘1’ + PO key 
Key test 
Z/PGM 
‘2’ + PO key 
Display test 
Z/PGM 
‘3’ + PO key 
Drawer test 
Z/PGM 
‘4’ + PO key 
Printer test 
Z/PGM 
‘5’ + PO key 
Printer Paper sensor test 
Z/PGM 
‘6’ + PO key 
AD conversion level test 
Z/PGM 
‘7’ + PO key 
CLOCK test 
Z/PGM 
‘8’ + PO key 
Destination display / ROM 
version 
Z/PGM 
‘9’ + PO key 
SD card test 
Z/PGM 
‘10’ + PO key 
RS232C (XE-A147 only) 
Z/PGM 
‘11’ + PO key 
ROM check (Japan only)   
Z/PGM 
‘12’ + PO key 
RAM check 
Z/PGM 
‘13’ + PO key 
 
 
 
 
 
 
 
 
3)  Description 
3-1)  MODE KEY SWITCH 
a. 
Test Procedure 
Change over the mode switch as follows. If the mode switch data 
in the proper sequence is not read with the above operation, an 
error is printed. 
To cancel this test mode, set the mode switch to any a position 
other than [Z/PGM] to [Z/PGM]. In this case, the completion print is 
performed. 
During the test, the display indicates hard codes which correspond 
to the switch position. 
 
The mode switch is set to the “OFF position”, it will no-display. 
 
<Note>   
In the test, the mode key should be fixed over 1second in each 
position. 
 
b. 
Mode switch operation 
MODE: [Z/PGM]  →  [X/FLASH]  →  [REG]  →  [OFF]  →  [VOID] 
 
c. 
Display 
   
    
 
 
 
 
    
 
 
 
 
   
 
 
 
 
   
 
 
 
 
 
 
 
 
[Z/PGM] 
[X/FLASH] 
[REG] 
[OFF] 
[VOID] 
Page of 28
Display