4-4   
 
Mode switch layout 
 
 
 
c.  Function 
 
Turns the display off. No operations are possible   
REG 
Permit transaction entry 
 
Permit correction after final a transaction 
X/Flash 
Permits printing of sales reports and display the 
flash reports 
Z/PGM 
Permits printing and resetting of sales reports and 
programming 
 
3)  BATTERY 
a.  MEMORY BACK UP BATTERY 
For memory back up, the dry battery ULM-3 (3 pieces) are 
needed. 
1. 
Memory holding time: 
Approx. 1 year after New dry batteries are installed. 
(It is depend on the battery capacity) 
2. 
Battery exchange method: 
When the low battery symbol "L" lights up, replace the 
batteries (3 AA) replaced by the following method; 
1)   Power on the ECR. 
2)   Mode switch turn to "REG" mode. 
3)   Remove the OLD dry batteries (3 pieces). 
4)   The no-battery symbol "
L
" light up. 
5)   Insert the NEW dry batteries (3 pieces). 
6)    Confirm the low battery symbol "L" and no-battery 
symbol "
L
" is off. 
 
b.  LOW BATTERY 
Low battery indication will appear on the left side of display when 
the battery voltage is low. 
CASE 1: When sitting idle or after completion of transaction. The 
machine can indicate the low battery condition (Always) 
CASE 2: Low battery indication will not appear during key 
operations, but will appear after power up of the cash 
register. 
[Display sample] 
“0.00”:    Battery is OK.   
"L 0.00": Low battery (The batteries have to be replaced.) 
After finalization 
"F 12.34": Battery is OK.   
"L 12.34": Low battery ("L" indicate instead of "F".) 
c.  NO BATTERY 
If the user forgets to replace the battery and the battery voltage 
falls below a certain level, or if a power failure occurs with no 
batteries installed, the memory contents cannot be retained. The 
CPU judges it as no battery and performs the master reset. In this 
case, all the settings and registrations are cleared. If, however, the 
power is continuously supplied to the AC cord, the memory 
contents are retained. 
Low battery:   
Batteries are installed, but the voltage is 
low. Memory back up can be done. 
No battery:    Batteries are not installed or the voltage is extremely 
low. The master reset is executed when a power 
failure occurs, when the batteries are not properly 
changed. 
Low battery & No battery indication will appear at the most left 
position of display when the battery voltage is low. 
CASE 1:    When any numeric entry & item entry is not done or 
just after 
finalization. 
The machine can indicate the battery condition. (Always) 
CASE 2: When numeric entry or item entry is done. 
Battery condition is not appeared. 
Exceptionally, at the power is restored after power failure, 
the low battery & No battery indication will appear on the 
display only when the battery voltage is low. 
And the indication will disappear after any key entry. 
[Display sample] 
"      0.00" : Battery is OK. 
"L 0.00" : Low battery 
"
L
 0.00" : No battery   
After finalization 
"F 12.34": Battery is OK. 
"L 12.34": Low battery ("L" indicate instead of "F".) 
"
L
 12.34": No battery ("L" indicate instead of "F" 
 
 
 
5-1 
 
CHAPTER 5. DIAGNOSTICS 
1.  XE-A137/XE-A147 
1)  Diagnostic menu 
 
DIAG menu 
DESCRIPTION 
1  Mode switch test 
To check the mode key function 
2  Key test 
Keyboard check 
3  Display test 
To check a display 
4  Drawer test 
To check a drawer opening 
5  Printer test 
Printer test 
6  Printer paper sensor test  To check a printer paper sensor 
7  AD conversion level test  AD conversion check 
8  CLOCK test 
To check the clock on CPU 
Destination display / 
ROM version 
To check the Destination setting and 
ROM version 
10  SD card test 
To check the SD-card write protection 
11  RS232C (XE-A147 only)  To execute the loopback test 
12  ROM (Japan only) 
To check the ROM for Japanese 
characters 
13  RAM 
To execute the RAM read write test 
 
2)  Entering procedure 
It is possible to enter the DIAG mode with following procedure;   
1. 
To set the mode switch to Z/PGM position 
2. 
To input the job code in accordance with below list 
3. 
To push the PO key 
4. 
Start the Diagnostic mode 
 
DIAG menu 
Mode key 
position 
Key code 
Mode switch test 
Z/PGM 
‘1’ + PO key 
Key test 
Z/PGM 
‘2’ + PO key 
Display test 
Z/PGM 
‘3’ + PO key 
Drawer test 
Z/PGM 
‘4’ + PO key 
Printer test 
Z/PGM 
‘5’ + PO key 
Printer Paper sensor test 
Z/PGM 
‘6’ + PO key 
AD conversion level test 
Z/PGM 
‘7’ + PO key 
CLOCK test 
Z/PGM 
‘8’ + PO key 
Destination display / ROM 
version 
Z/PGM 
‘9’ + PO key 
SD card test 
Z/PGM 
‘10’ + PO key 
RS232C (XE-A147 only) 
Z/PGM 
‘11’ + PO key 
ROM check (Japan only)   
Z/PGM 
‘12’ + PO key 
RAM check 
Z/PGM 
‘13’ + PO key 
 
 
 
 
 
 
 
 
3)  Description 
3-1)  MODE KEY SWITCH 
a. 
Test Procedure 
Change over the mode switch as follows. If the mode switch data 
in the proper sequence is not read with the above operation, an 
error is printed. 
To cancel this test mode, set the mode switch to any a position 
other than [Z/PGM] to [Z/PGM]. In this case, the completion print is 
performed. 
During the test, the display indicates hard codes which correspond 
to the switch position. 
 
The mode switch is set to the “OFF position”, it will no-display. 
 
<Note>   
In the test, the mode key should be fixed over 1second in each 
position. 
 
b. 
Mode switch operation 
MODE: [Z/PGM]  →  [X/FLASH]  →  [REG]  →  [OFF]  →  [VOID] 
 
c. 
Display 
   
    
 
 
 
 
    
 
 
 
 
   
 
 
 
 
   
 
 
 
 
 
 
 
 
[Z/PGM] 
[X/FLASH] 
[REG] 
[OFF] 
[VOID] 
 
5-2 
 
d. 
Test result print 
When a test results is OK, following result is printed out 
 
 
 
 
When a test result is NG, following result is oriented out. 
 
 
 
 
 
 
3-2) KEY TEST 
a. 
Test Procedure 
Perform the keyboard check with the sum check data of the key 
code. 
Enter the any key other than [TL] key, and then enter the [TL] key, 
finally. In the process above, machine records the sum, and after 
[TL] key entered, compare with check sum proper check sum. 
It is possible to re-operate from the beginning, enter the [CL] key 3 
times, when operation is wrong. 
b. 
Display 
 
 
 
 
 
 
c. 
Test result print 
When a test results is OK, following result is printed out 
 
 
 
 
When a test result is NG, following result is printed out. 
 
 
 
 
 
 
 
 
 
 
 
 
 
3-3) DISPLAY TEST 
a. 
Test Procedure 
Check the continuous buzzer sound and the display state. 
 
<Check points> 
1. 
The all segments are lighted up correctly. 
2. 
The brightness of all segments is same level. 
 
1. 
Segments display test 
The following pattern is displayed. When [TL] key  pushed, 
the display pattern is changed to next. 
 
 
< Display > 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  MODE KEY SWITCH    OK 
 
 
MODE KEY SWITCH    NG 
 
Original check sum: 
1761(4 digits) 
Entered key code: 
(According to entering) 
 
KEY XXXX-YYYY - OK 
 
 
KEY XXXX-YYYY - NG 
 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
 
5-3 
 
2. 
Shift display test 
The following pattern is displayed. When [TL] key pushed, 
the display pattern is changed to next. 
Finally, all segments are lighted on. 
 
< Display > 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. 
Completion of test 
When [TL] key pushed after above test, the test is finished 
as OK status. 
When other than [TL] key pushed after above test, the test 
is finished as NG status. 
 
 
b. 
Test result print 
When a test results is OK, following result is printed out 
 
 
 
 
When a test result is NG, following result is printed out. 
 
 
 
 
 
 
3-4) DRAWER TEST 
a. 
Test Procedure 
The drawer opens with the above key operation. Check that the 
drawer is open.   
After drawer open, check the drawer opening, 
When drawer open correctly, push the [TL] key, test will finish with 
OK status. 
If not, push other than [TL] key, test will finish with NG status. 
 
b. 
Test result print 
When a test results is OK, following result is printed out 
 
 
 
 
When a test result is NG, following result is printed out. 
 
 
 
 
 
 
3-5) PRINTER TEST 
a. 
Test Procedure 
With the above key operation, the print test pattern is  printed  as 
below. 
 
Check the print results. 
When print result is OK, push the [TL] key, test will finish with OK 
status. 
If not, push other than [TL] key, test will finish with NG status. 
 
 
 
 
 
 
 
 
 
 
DISPLAY&BUZZER    OK 
 
 
DISPLAY&BUZZER   NG 
 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
[TL] key pushed 
 
  DRAWER    OK 
 
 
  DRAWER   NG 
 
 
  ///////////  -------   ///////////   
///////////  -------   /////////// 
 
///////////  -------   /////////// 
 
////////////////////////////////////////////// 
////////////////////////////////////////////// 
All “/” 6 lines 