UP800 Series
Terminals Freezing
Scanner connection CH2 & In-line system
1. Model:          
UP-800 Series ROM Version 1.02
2. General:
It has been reported that the terminals can freeze while
performing a T-Log communication such as calling up
Customer Accounts, on an In-line system while using a
scanner connected to CH2
3. Cause:
This symptom is caused by the connection of Scanner to
Channel 2. This can be avoided by having the Scanner
connected to a channel other than Cannel 2 (1, 3 or 4)
The symptoms will only occur if the In-line system is used.
4. Action:
Please avoid connecting the barcode scanner to CH2.
This issue is a software defect, so a corrective change of
software will be implemented in the next upgrade.
(For the field)
Please avoid connecting the barcode scanner to CH2, if using In-line system.
(For production)
There will be a ROM upgrade, which will incorporate a fix at the next release.
Display

Sharp UP-800 (serv.man84) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp UP-800 (serv.man84) Service Manual ↓ Size: 17 KB | Pages: 1 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp UP-800 (serv.man84) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp UP-800 (serv.man84) ECR. Information contained in Sharp UP-800 (serv.man84) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.