Sharp UP-800 (serv.man34) User Manual / Operation Manual ▷ View online

51
■ With/without entries
A maximum of 10 tied PLUs of the Combo PLU can be modified (added or deleted) temporarily by using 
W
and 
w
keys.
With:
To add a PLU to the combo PLU/EAN.
Without:
To delete a linked PLU from the combo PLU/EAN.
The “with” and “without” operation is allowed a total of 20 times.
■ PLU Menu entries
*Less than the programmed upper limit amounts
To exit the menu screen, press the 
h
key.
A
[
Select PLU code 15      
]
from the menu window.
c
Display
Key operation
Example
NOTE
*Unit price
thru
`
B
A
Item selection
Item selection
PLU/subdept. entry 
(preset/open and preset)
When using a programmed 
unit price
Subdept. entry (open)
Procedure
w
17 
s
W
16 
s
12 
s
c
Print
Key operation
Example
NOTE
Direct PLU
Direct PLU
PLU code
to be added
(To be added)
(To be deleted)
With:
Without:
w
W
s
Ä
s
s
Direct PLU
Tied PLU code
to be deleted
s
To enter the next PLU code to be added
To enter the next PLU code to be deleted
Combo PLU code
Combo EAN code
Scan Combo EAN code
(Combo PLU)
Procedure
52
■ PLU level shift (for direct PLUs)
This shift can add to the number of direct PLUs on your POS terminal without adding additional direct PLU
keys. You can use direct PLUs in ten levels by utilizing the PLU level shift number key 
ä
or the PLU level
shift keys 
thru 
A
Level key shifts the PLU level from the other nine to the required level. (The normal level is the level 1.)
You must program your machine in the PGM mode to select one of the two PLU level shift modes —
automatic return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the
REG and MGR modes or in the MGR mode alone.
*  The automatic return mode automatically shifts the PLU level back to level 1 after pressing a direct PLU
key or finalizing each transaction.
** The lock shift mode holds the current PLU level until depression of a PLU level shift key.
Automatic return mode (for PLU levels)
If your terminal has been programmed for PLU level in the automatic return mode, press a desired PLU
level shift key before a numeric entry.
When you use the FF method,  you need not press the 
x
key for multiplication entries.
NOTE
Direct PLU
(Finalization)
(Q’ty,         ) 
Numeric entry
Direct PLU
Return to level 1
(Q’ty,         ) 
Numeric entry
(Returning every item entry)
(Returning every transaction)
n
through
n:PLU shift no.
x
x
A
n
through
A
ä
ä
Procedure
53
Lock shift mode (for PLU levels)
If your terminal has been programmed for PLU level in the lock shift mode, press a desired PLU level shift
key before a numeric entry.
When you use the FF method,  you need not press the 
x
key for multiplication entries.
Level 1 : PLU code 1, PLU code 2
Level 2 : PLU code 70, PLU code 65
• When your POS terminal has been programmed for the automatic return mode (by one item):
• When your POS terminal has been programmed for the lock shift mode:
ä 1
ä 1
2
c
Print
Key operation
1
ä 1
2
c
Print
Key operation
Example
NOTE
Direct PLU
Stay in the current level
(Q’ty,         ) 
Numeric entry
x
n
through
A
ä
Procedure
54
■ Price level shift
Eight different price levels can be programmed for each PLU/EAN.
The price levels can be changed for PLU/EAN registrations.
You can shift the PLU/EAN price level (level 1 thru 8) by utilizing the price level shift number key 
>
or the
price shift keys 
>
thru 
B
.
You must program a price level shift mode (i.e. automatic return mode* or lock shift mode**) and the
operating modes to be used for the price level shift (i.e. both REG and MGR modes or MGR mode alone).
*  The automatic return mode automatically shifts the PLU/EAN price level back to level 1 after a PLU/EAN
shift entry.  You can select whether the price level should return each time you enter one item or each
time you finalize one transaction.
** The lock shift mode holds the current PLU/EAN price level until pressing a price level shift key.
Automatic return mode (for price shifts)
If your terminal has been programmed for PLU/EAN price level in the automatic return mode, press a
desired price level shift key before a numeric entry.
When you use the FF method,  you need not press the 
x
key for multiplication entries.
Lock shift mode (for price shifts)
If your terminal has been programmed for PLU/EAN price level in the lock shift mode, press a desired price
level shift key before a numeric entry.
When you use the FF method,  you need not press the 
x
key for multiplication entries.
NOTE
To shift the price level of another PLU/EAN
(Q’ty,        etc.) 
Numeric entry
x
Stay in the current
price level
>
B
n
through
n: Price shift level no.
s
s
Direct PLU
PLU code
EAN code
Ä
>
Procedure
NOTE
(each item)
s
s
Direct PLU
PLU code
EAN code
(Q’ty,       etc.) 
Numeric entry
x
Ä
>
B
(each transaction)
[Payment]
(Q’ty,       etc.) 
Numeric entry
x
Return to 
the default
price level
(start level)
for the clerk
n
through
>
B
n
through
n: Price shift level no.
n: Price shift level no.
s
s
Direct PLU
PLU code
EAN code
Ä
>
>
Procedure
Page of 127
Display

Click on the first or last page to see other UP-800 (serv.man34) service manuals if exist.