View Sharp ER-A460 (serv.man19) Technical Bulletin online
SPECIAL SERVICE PRESET (SSP) TO PREVENT A
TRANSMISSION ERROR ON AN ER-02FD
TRANSMISSION ERROR ON AN ER-02FD
[Event report]
1. Model name:
ER-A460/A470
2. General:
The following change to the software will be carried out for the communication between
ER-A460/70 and ER-02FD.
3. Description:
(Current phenomenon)
A transmission error occurs during data transmission from an ECR to an ER-02FD, sometimes
data is not transmitted.
(Improvement)
Input the attached SSP to prevent data transmission.
4. Action:
((For the field))
SSPERA460V-001 will be released against the above contents.
(For machines with ROM version "27020RAU1A" ONLY.)
5. Remarks:
1) SSP Inputting Order
2) SSP Input Contents and Printed Example
1/5
Date :
Model :
Ref :
Colour
Code :
10th July 1996
ERA460
A460-005
White
ELECTRONIC CASH REGISTER
TECHNICAL BULLETIN
Sharp Electronics (UK) Ltd, Technical Support Group
SSP INPUTTING ORDER
1) Turn to the SRV MODE, input 130
→
TL and confirm the ROM version number.
(Refer to the Printed Example.)
2) Input the SSP in accordance with the attached SSP Inputting Data.
3) Check the printed receipt by comparing it with the Inputting Data.
4) In case an error is found, correct the SSP data in the following sequence.
991
→
[
•
]
→
[ X ]
→
XXX
→
[ X ]
→
YYY
→
[ST]
→
[TL]
XXX: STEP number YYY: SSP data
5) Switch off and on by pulling out the plug and inserting it.
Printed example:
130
ROM
27020RAU1A
RAU1A
RAU1A
The underlined part means
the ROM version number.
(In this example, the ROM
version number is RAU1A.)
the ROM version number.
(In this example, the ROM
version number is RAU1A.)
2/5
3/5
4/5