CHAPTER 5. REMOVING THE
PRINTER UNIT (For
ER-A310 & ER-A330)
1. ER-A310
1) Remove the top cabinet.
2) Remove the printer cable 
1
 from the main PWB.
3) Remove the three screws 
2
.
4) Remove the screw 
3
 and grounding wire 
4
.
5) Remove the printer unit 
5
 from the top cabinet.
2. ER-A330
1) Remove the top cabinet.
2) Remove the printer cable 
1
 from the main PWB.
3) Remove the three screws 
2
.
4) Remove the screw 
3
 and grounding wire 
4
.
5) Remove the printer unit 
5
 from the top cabinet.
CHAPTER 6. REMOVING THE MAIN
PWB (For ER-A310 &
ER-A330)
1. ER-A310/A330
1) Remove the top cabinet. 
2) Remove the printer unit. 
3) Remove the following connector cables from the main PWB. 
Dry battery cable 
1
Pop up display cable 
2
Note: The pop-up cable is fixed with the holder not to make con-
tact with the heat radiating plate on the main PWB. Be
careful of it when installing.
Mode switch cable 
3
Keyboard cable 
4
4) Remove the screw 
5
 and grounding wire 
6
.
5) Remove the free screws 
7
 and main PWB 
8
.
1
2
3
4
5
1
3
4
5
2
2
1
2
3
4
5
6
7
8
7
– 4 –
CHAPTER 7. REMOTE DRAWER:
ER-04DW (For
ER-A310 & ER-A330)
CAUTION:
The drawer unit should be securely fitted to the supporting platform
to avoid instability when the drawer is open.
1. Outline
The ER-A310/A330 allows connection of one remote drawer ER-
04DW.
Note on the drawer connector
The main PWB has no part for connection of the remote drawer. In
order to connect the remote drawer, the following parts must be at-
tached to the main PWB. 
LOCATION No.
ER-A310 ER-A330
PARTS CODE
DESCRIPTION
CN16
CN16
QCNCM7057BHZZ
Drawer connector
R80
R89
VRD-RC2EY102J
Resistor (1K
)
Q20
Q20
VS2SC3784-/-1
Transistor (2SC3784)
2. Installation procedure for ER-A310
1) Remove the top cabinet. 
2) Remove the main PWB.
3) Solder the drawer connector CN16, the resistor (1k
) R80, and
the transistor (2SC3784) Q20 to the main PWB.
4) Replace the main PWB. 
5) Connect the drawer cable to the drawer connector on the main
PWB. 
6) Use nippers to cut off drawer cable binding holder 
1
 on the trans
cover, and bind drawer cable 
2
 of the ER-04DW.
Screw 
3
 used in this case is an accessory of the ER-04DW.
7) Use nippers to cot off the drawer cable split pin of the top cabinet,
and attach the top cabinet. 
8) Fix ground wire 
4
 of the ER-04DW on the standard drawer with
screw 
5
.
Screw 
5
 used in this case is an accessory of the ER-04DW. 
DR1
JMS
R 53
 1K
R 54
15K
VP:+24V
L 2
R 55
15K
ER-A310:Q14
ER-A330:Q21
C3784
CN11
VP:+24V
ER-A310:Q20
ER-A330:Q14
C3784
R 56
56K
R 57
ER-A310:3.3K
ER-A330:4.7K
ER-A310:R80
ER-A330:R89
1K
DR2
OPTION
DRAWER
STANDARD
DRAWER
IC2
CPU
CN 16
R80
 1K
Q20
C3784
IC2
CP
U
ER-A310
Main PWB
CN 16
R89
 1K
Q20
C3784
IC2
CP
U
ER-A330
Main PWB
CN16
2
4
5
ER-04DW
CN16
Main PWB.
1
3
2
1
3
2
– 5 –
3. Installation procedure for ER-A330
1) Remove the top cabinet. 
2) Remove the main PWB.
3) Solder the drawer connector CN16, the resistor (1k
) R89, and
the transistor (2SC3784) Q20 to the main PWB.
4) Replace the main PWB. 
5) Connect the drawer cable to the drawer connector on the main
PWB. 
6) Use nippers to cut off drawer cable binding holder 
1
 on the bottom
cabinet, and bind drawer cable 
2
 of the ER-04DW.
Screw 
3
 used in this case is an accessory of the ER-04DW.
7) Use nippers to cot off the drawer cable split pin of the top cabinet,
and attach the top cabinet. 
8) Fix ground wire 
4
 of the ER-04DW on the standard drawer with
screw 
5
.
Screw 
5
 used in this case is an accessory of the ER-04DW. 
4. Operation test
CHAPTER 8. DRAWER FIXING KIT
(DKIT–8633RCZZ)
The drawer fixing kit is used for securing the cash drawer when in-
stalling separately from the ECR main unit or remote drawer.
By using two of brackets, the drawer box can be protected from
drifting especially when it is filled with coins.
1. Parts list
KIT CODE: DKIT–8633RCZZ
No.
Parts code
Description
Q’ty
1
LBRC–2321RCZZ
Fixing bracket
2
2
XTPSD40P16000
Tapping screw M4x16
4
3
XBSSD40P16000
Flat head screw M4x16
(For remote drawer)
2
4
XUSSD40P20000
Flat head screw M4x20
(For standard drawer)
2
5
XBPSD40P22000
Screw M4x22
4
6
XNESD40–32000
NUT M4x32
4
4
5
CN16
Main PWB.
1
3
2
– 6 –
2. Installation procedure
1) Turn over the drawer bottom side and remove rubber footing at
two to locations.
2) Fasten the bracket together with the rubber footing using the pand
hand screw.
Pay attention for the installing direction of the bracket that the pan
head screw can be inserted properly into the bracket.
Fig. 1
3) Fastening on the table:
Secure the fixing Bracket using the screw (Fig. 2).
If the thickness of the table is less than 15mm, bore a 4.5mm hole
in the table and fasten it with the screw (XBPSD40P22000 - 4pcs.)
and nut (XNESD40-32000 - 4pcs.).
Fig. 2
CHAPTER 9. SHIELD PLATE KIT:
DKIT-8666BHZZ (Only
for ER-A330)
1. Component list
No.
PARTS CODE
DESCRIPTION
Q’TY
1
LCHSM6705BHZZ
SHIELD PLATE
1
2
PGUMM6696BHZZ
GUM LEG
4
3
TLABH7054BHZZ
CAUTION CARD
4
4
XUBSD30P12X00
SCREW
1
5
XUBSD30P08000
SCREW
1
6
XJPSD30P12X00
SCREW
1
7
XJPSD40P12X00
SCREW
1
8
XHBSD30P08000
SCREW
3
9
LBSHC0004AGZZ
CLAMP
1
2. Installation procedure
1) Remove the top cabinet.
2) Remove the bottom cabinet.
3) Install the shield plate 
1
 to the bottom cabinet and fix it with ???
screws 
2
.
4) Attach four gum legs 
3
 to the shield plate and fix them with screws
4
.
5) Replace the top cabinet.
Pan head screw
Fixing bracket
Rubber footing
Cash drawer
Drawer bottom plate
Rubber footing
Fixing bracket
Pan head screw
Fixing bracket
Tapping screw
1
2
3
4
3
3
2
2
– 7 –
Page of 10