Sharp ER-A280 / ER-A280N / ER-A280F (serv.man7) User Manual / Operation Manual ▷ View online
111
■ EAN Non-PLU code format
C
D
Free format
Flag
(02 or 20-29)
Field 2
Field 1
Free format area
Price check digit
EAN-13 type
EAN-8 type
2
C
D
Free format
Flag
Program each item as follows:
• TYPE OF CODE (Use the selective entry)
EAN-8:
EAN-8 format code (consisting of 8 digits)
EAN-13 (UPC-A): EAN-13 format code (consisting of 13
digits)
• SYSTEM CODE (Use the numeric entry)
System code (i.e. flag code): EAN-8: 1 digit, EAN-13: 2 digits
ISBN/ISSN and press code are always used the fixed format even
if code, 37, 43, 78, 98, or 97 is entered.
if code, 37, 43, 78, 98, or 97 is entered.
• LENGTH FLD#1 (Use the numeric entry)
Length of field 1 (number of digits): 0 to 9
• LENGTH FLD#2 (Use the numeric entry)
Length of field 2 (number of digits): 0 to 9
• FLD#1 DATA
Meaning of field 1: It is fixed to FREE.
• FLD#2 DATA (Use the selective entry)
Meaning of field 2
QUANTITY: Quantity
PRICE:
QUANTITY: Quantity
PRICE:
Price
• CHECK DIGIT (Use the selective entry)
Price check digit
YES: Use the price check digit
NO:
YES: Use the price check digit
NO:
Not use the price check digit
• TAB (Use the selective entry)
TAB or decimal point of field: 3/2/1/0
NOTE
The screen continues.
Procedure
▼
Select a arbitrary number, or a
pertinent EAN TYPE OF CODE &
SYSTEM CODE you set.
pertinent EAN TYPE OF CODE &
SYSTEM CODE you set.
ER-A280F_N(SEEG)(E)-6 09.6.18 6:53 AM Page 111
112
■ Press code (for EAN)
Your register allows to program the press code format.
Program each item as follows:
• TABLE NUMBER (1 to 5) (Use the selective entry)
1: GERMAN TYPE1 (prefix code: 434/439)
2: U.K. (prefix code: 988/989)
3: FRANCE (prefix code: 378/379)
4: SWEDEN (prefix code: 7388)
5: GERMAN TYPE2 (prefix code: 414/419)
2: U.K. (prefix code: 988/989)
3: FRANCE (prefix code: 378/379)
4: SWEDEN (prefix code: 7388)
5: GERMAN TYPE2 (prefix code: 414/419)
• TYPE OF CODE (Use the selective entry)
NORMAL: Normal EAN
PRESS:
PRESS:
Press code
• PRICE (Use the selective entry)
Price entry method for press code (This setting is valid only
when PRESS CODE is set for TYPE OF CODE.)
PRESET:
when PRESS CODE is set for TYPE OF CODE.)
PRESET:
Using the EAN preset price
ENCODED:
Using the encoded price
COMPULSORY: Compulsory entry
• LABEL TYPE (Use the selective entry)
Label of record in EAN file (This setting is valid only when
PRESS CODE is set for TYPE OF CODE.)
ARTICLE: Prefix + article code
PRESS CODE is set for TYPE OF CODE.)
ARTICLE: Prefix + article code
Select this option when you want to summarize
the sales of items having press codes by each
item.
the sales of items having press codes by each
item.
PREFIX:
Prefix only
Select this option when you want to summarize
the sales of items having press codes by
category.
Select this option when you want to summarize
the sales of items having press codes by
category.
Procedure
▼
ER-A280F_N(SEEG)(E)-6 09.6.18 6:53 AM Page 112
113
■ EAN delete
You can delete the EAN codes which have not been accessed during the period you set in this program
when you execute the delete job in EAN DELETE in X1/Z1 mode.
when you execute the delete job in EAN DELETE in X1/Z1 mode.
Program each item as follows:
• PERIOD (DAY) (Use the numeric entry)
Enter the EAN record delete period: 01 to 99 (00: Not delete
by the non-accessed deleting job)
by the non-accessed deleting job)
Procedure
■ PLU/EAN stock
You can assign a stock quantity to each PLU/EAN code.
Shown below is an example of selecting “1 OVER WRITE.”
Shown below is an example of selecting “1 OVER WRITE.”
After selecting “1 OVER WRITE,” select a pertinent PLU/EAN
code. Then the next screen will appear to show the following
items:
code. Then the next screen will appear to show the following
items:
• CURRENT ST
The current stock is displayed.
• NEW STOCK (Use the numeric entry)
Enter a new stock quantity (max. 7 digits: 1 to
9999.999(9999999))
9999.999(9999999))
• If you need to add or subtract a stock quantity to or from the
current stock quantity, select “2 ADD” or “3 SUB” and enter a
value to be added or subtracted.
value to be added or subtracted.
• You cannot enter any values for the item marked with “!”.
• The entry of a new stock value will update to the PLU/EAN stock
• The entry of a new stock value will update to the PLU/EAN stock
counter.
NOTE
Select a pertinent PLU code, or
directly enter a PLU code or EAN
code.
directly enter a PLU code or EAN
code.
Procedure
▼
▼
ER-A280F_N(SEEG)(E)-6 09.6.18 6:53 AM Page 113
114
Press the key on the keyboard.
In the case of selecting “DIRECT PLU”
• TYPE (Use the selective entry)
PLU:
Assigns the key as a direct PLU key.
DEPT:
Assigns the key as a direct department key.
INHIBIT: Non-use
• You can also select a direct PLU key by pressing the
corresponding key when the PLU has been assigned directly on
the keyboard instead of selecting the key from the menu.
the keyboard instead of selecting the key from the menu.
• When selecting a department, the screen on which a department
code is to be entered (the message “DEPT. CODE”) will appear.
• LEVEL1 through 3 (Use the numeric entry)
Enter a PLU code for each level. For example, if you want to
use this key as PLU code 1 (level 1) and PLU code 101 (level
2), enter 1 for “LEVEL1” and 101 for “LEVEL2.”
use this key as PLU code 1 (level 1) and PLU code 101 (level
2), enter 1 for “LEVEL1” and 101 for “LEVEL2.”
Key numbers
(ER-A280F)
NOTE
Procedure
▼
▼
▼
Direct Key Programming
Use the following procedure to select direct-key programming.
■ Direct key
You can assign departments and PLUs directly to the keyboard. In the case of PLUs, you may assign up to
3 levels to be accessed directly on the keyboard. For key no. positions, refer to the illustration shown below.
3 levels to be accessed directly on the keyboard. For key no. positions, refer to the illustration shown below.
33
41
31
39
30
38
29
37
28
36
27
35
26
34
50
59
48
57
47
56
46
55
45
54
44
53
43
52
• You can assign departments and PLUs only the “Departments
and PLUs programmable area” shown above.
• You cannot assign a department or a PLU to the position to
which a function key has been assigned.
NOTE
(ER-A280N)
: Departments and PLUs programmable area
20
26
19
25
18
24
17
23
33
32
31
30
ER-A280F_N(SEEG)(E)-6 09.6.18 6:53 AM Page 114