DOWNLOAD Sharp ER-A280 / ER-A280N / ER-A280F (serv.man4) Service Manual ↓ Size: 1.2 MB | Pages: 49 in PDF or view online for FREE

Model
ER-A280 ER-A280N ER-A280F (serv.man4)
Pages
49
Size
1.2 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ER-A280 Programming Manual
File
er-a280-er-a280n-er-a280f-sm4.pdf
Date

Sharp ER-A280 / ER-A280N / ER-A280F (serv.man4) Service Manual ▷ View online

ER-A280F/280N (V)
PGM MODE PROGRAMMING (“SETTING”)
3 – 10
15. FUNCTION TEXT
16. MESSAGE
17. AUTO GENE.GLU
18. TAX
19. AUTO KEY
          *PGM2*           
FUNCTION TEXT 
                               
NET1          NET1__12 
DIFFER            DIFFER 
TAX1 ST           TAX1 ST     
Mode title 
Report title
Function text(Default) / Function text(Preset)
          *PGM2*
MESSAGE 
                               
RECEIPT LOGO                    
THANK YOU 
FOR YOUR 
PURCHASE 
WE ARE LOOKING 
FORWARD TO 
YOUR NEXT VISIT 
Mode title
Report title
Title text
Logo text (position 1)
Logo text (position 2)
Logo text (position 3)
Logo text (position 4)
Logo text (position 5)
Logo text (position 6)
          *PGM2*           
AUTO GENE. GLU 
                               
                        1-9999 
 
Range of auto generate GLU
Mode title
Report title
          *PGM2*           
TAX 
                               
TAX1          10.0000% 
                      0.10 
TAX2        -12.3456% 
                  999.99 
TAX3                      ---- 
TAX4          -3.0000% 
                      0.00 
TAX5                      ---- 
TAX6                      ---- 
Job mode
Report title
TAX teble# / Sign & Rate  
Lower TAX limit
Undefined TAX
2)/
#761-';5'3


-';
-';
616#.

&
&
2
Mode title
Report title
1st key text
2st key text
Department# 01
Department# 02
PLU 00001
ER-A280F/280N (V)
PGM MODE PROGRAMMING (“SETTING”)
3 – 11
20. DEVICE CONFIG
21. DIRECT KEY
22. ONLINE CONFIG
(*1) CI signal NO : A
(*2) Half duplex sys. : A
(*3) Program : A
          *PGM2*           
DEVICE CONFIG 
                               
BUILT-IN PRINTER 
 LIGHT&SHADE                50 
 IMAGE FOOTER        NOT PRINT 
 DIFF ST FEED                0 
BCR(SCANNER)       C#0 71  ODD 
                       4800bps 
ONLINE                     C#2 
CONTROL UNIT               C#2 
                      38400bps 
 
Mode title
Report title
Device name(Built-in printer)
Device name(ONLINE) / Channel#
Light & Shade
Footer graphic logo print
Diff ST line
Device name(BCR) / Channel# / Program('1) / Parity
Baud rate
Baud rate
Device name(CONTROL UNIT) / Channel#
          *PGM2*           
DIRECT KEY 
                               
001                  D01 
002                  D03 
003          L 1    P00001 
                L 2    P00101 
                L 3    P00201 
003          L 1       ---- 
                L 2    P00101 
                L 3    P00201 
005                    ---- 
006          L 1    P00006 
Job mode
Report title
Key position / Department code or PLU code
(for Department code)
(for PLU code)
(for PLU code 00000) 
(for Inhibit key or other free key) 
(all direct key)
2)/
10.+0'%10(+)

6'4/+0#.01
/1&'/%10641.
$25
56#46%1&'
'0&%1&'
6+/'176
Mode title 
Report title
Terminal number
CI signal NO('1) / Half duplex sys.('2)
4800 bps('3)
The start code is DC1(11h)
The end code is ETX(03h)
Time out time 7 sec
A:
CI signal NO
0:NON
1:SENSING
A:
Half duplex sys.
0:FULL
1:HALF
A:
BAUD RATE
8:57600bps
7:38400bps
6:19200bps
5:9600bps
4:4800bps
ER-A280F/280N (V)
PGM MODE PROGRAMMING (“SETTING”)
3 – 12
23. VMP COFIG
24. ROM VERSION
          *PGM2*
VMP PRESET 
                               
PASSWORD                  0000 
VMP1 PASSWORD             0000 
VMP2 PASSWORD             0000 
VMP3 PASSWORD             0000 
VMP1 ID             0000000000 
VMP2 ID             0000000000 
VMP3 ID             0000000000 
Mode title
Report Title
2)/
8'45+10

+2.8GTUKQP
'4#8
241)4#/8GTUKQP
'4#8
8GT
6':68GTUKQP
6GZV8
5;56'/8GTUKQP
5[UVGO8
Mode title
Report Title
IPL software version
Application software version
Language version
System software version
ER-A280F/280N (V)
PGM MODE PROGRAMMING (“SETTING”)
3 – 13
2. ARTICLE
2-1. DEPARTMENT (PGM1, 2)
DEPT CODE: 2 digits (1 to 99) MRS = 1to12
The register is equipped with 12 standard departments, and can be
equipped with a maximum of 99 departments.
*1: If a price is set for a department which amount entry type is “INHIBIT” or “OPEN”, its amount entry type is set as below automatically.
“INHIBIT” 3 “PRESET”
“OPEN”
3 “OPEN&PRESET”
*2: Items A and B indicate  A x 10
B
.
Any amount below that value is enable within 99999999.
*3: Selection of the group “HASH” is inhibited when the HASH function is programmed as disabled in SRV mode.
Item
PGM1
Text
Range/Detail
Sweden 
fiscal
default
Price
O
PRICE
Amount 8 digits (0 to 99999999) *1
0
Item Text
TEXT
16 characters
DPT.xx
Group No.
GROUP No.
01-09 : Plus department  *3
10 : Minus department
11 : Plus HASH department
12 : Minus HASH department
13 : Plus Bottle Return dept.
14 : Minus Bottle Return dept.
1
Amt. entry type
ENTRY TYPE
OPEN&PRESET
PRESET
OPEN
INHIBIT
OPEN
Commission Group
COMMISSION#
1-9: Commission Group No.
0: N/A
0
SIF/SICS/Normal
SALES TYPE
SIF
SICS
NORMAL
NORMAL
PRINT ON CLK
PRINT ON CLK
YES
NO
YES
HALO
HALO
AB:2digits  *2
A: Mantissa(0 to 9)
B: Exponent(0 to 8)
18
VMP Number of EAN
VMP No.
1-3: VMP file number of EAN
0: N/A
0
Taxable 1
TAXABLE1
YES
NO
NO
Taxable 2
TAXABLE2
YES
NO
NO
Taxable 3
TAXABLE3
YES
NO
NO
Taxable 4
TAXABLE4
YES
NO
NO
Taxable 5
TAXABLE5
YES
NO
NO
Taxable 6
TAXABLE6
YES
NO
NO
Age Verification
AGE VERIFY
YES
NO
(Fixed)
NO
NO
Page of 49