DOWNLOAD Sharp DV-S15 (serv.man18) Service Manual ↓ Size: 3.75 MB | Pages: 64 in PDF or view online for FREE

Model
DV-S15 (serv.man18)
Pages
64
Size
3.75 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD / Complete
File
dv-s15-sm18.pdf
Date

Sharp DV-S15 (serv.man18) Service Manual ▷ View online

Audio Block Diagram
IC801 (AUDIO DAC)
7
8
12
11
DIGITAL
AUDIO OUT
JK1201
AMP
Q1351
IC1201
Q1203
Q1201
Q1202
VREF
+3.3V
(AMP)
CN701
CN1601
CN701
CN1601
16
16
AUDIO-L
18
18
AUDIO-R
15
15
A-L-MUTE
17
17
A-R-MUTE
19
19
A-MUTE
AUDIO-L
OUT
1
2
3
13
14
15
16
FROM
VIDEO
BLOCK
DIAGRAM
SERIAL
PORT
SERIAL
CONTROL
4X/8X
OVERSAMPLING
DIGITAL FILTER
/FUNCTION
CONTROLLER
ENPHANCED
MULTI-LEVEL
DELTA-SIGMA
MODULATOR
DAC
LPF+AMP
L-CH
R-CH
LPF+AMP
DAC
ZERO DETECT
SYSTEM CLOCK
1
2
6
7
5
AUDIO-R
OUT
PCM-BCK
SPDIF
PCM-DATA0
PCM-LRCLK
ADAC-MD
ADAC-MC
ADAC-ML
PCM-SCLK
AV CBA
DVD MAIN CBA UNIT
AUDIO SIGNAL
DATA(AUDIO) SIGNAL
21
21
SPDIF
A-MUTE
+3.3V
Q1204
WF6
3
WF4
WF5
JK1404
1
3
AUDIO-L
OUT
AUDIO-R
OUT
1-9-9
1-9-10
E56H0BLA
Power Supply Block Diagram
CAUTION !
Switching power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the
power supply circuit are not defective before you connect the AC plug to
the AC power supply. Otherwise it may cause some components in the
power supply cir cuit to fail.
    A     V
AC1001
AC CORD
F1001
T1.6A L 250V
LINE
FILTER
L1001
D1001, D1002
D1004, D1005
Q1003
Q1008
Q1001
2
4
7
3
4
IC1001
ERROR
VOLTAGE DET
T1001
11
12
13
15
14
16
17
18
-FL
EV+3.3V
F1
F2
P-ON+5V
P-ON+3.3V
P-ON+12V
EV+5V
IC1006
(SHUNT REGULATOR)
SWITCHING
D1008
D1030
RECTIFIER
D1003
RECTIFIER
D1009
RECTIFIER
D1013
D1016
RECTIFIER
SWITCHING
CONTROL
SWITCHING
CONTROL
REG
1
2
6
BRIDGE
RECTIFIER
HOT
AV CBA
 +1.8V
REG.
1
2
3
4
5
6
14
15
16
17
18
19
20
P-ON+1.8V
P-ON+1.8V
 EV+2.5V
 EV+2.5V
P-ON+5V
P-ON+5V
 EV+9V
 EV+9V
  EV+3.3V
 P-ON+3.3V
PWRCON
 P-ON+3.3V
 P-ON+3.3V
5V
REG. 
   
Q1014
Q1006
Q1002
CN1001
Q1011
Q1005
Q1004
IC1002
IC1003
Q1007
REG
(SHUNT REGULATOR)
HOT CIRCUIT. BE CAREFUL.
E56H0BLP
1-9-12
1-9-11
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE T1.6A  L  250V FUSE.
NOTE : 
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
SCHOTTKY
BARRIER
SCHOTTKY
BARRIER
1-10-1
SC-FN2
Standard Notes
WARNING
Many electrical and mechanical parts in this chassis
have special characteristics. These characteristics often
pass unnoticed and the protection afforded by them
cannot necessarily be obtained by using replacement
components rated for higher voltage, wattage, etc.
Replacement parts that have these special safety
characteristics are identified in this manual and its
supplements; electrical components having such
features are identified by the mark " ! " in the schematic
diagram and the parts list. Before replacing any of these
components, read the parts list in this manual carefully.
The use of substitute replacement parts that do not
have the same safety characteristics as specified in the
parts list may create shock, fire, or other hazards.
Capacitor Temperature Markings
Mark
Capacity
change rate
Standard 
temperature
Temperature
range
(B)
(F)
±10%
+30 - 80%
±15%
+30 - 80%
20
°C
20
°C
20
°C
20
°C
-25~+85
°C
-25~+85
°C
-25~+85
°C
-10~+70
°C
(SR)
(Z)
Capacitors and transistors are represented by the
following symbols.
SCHEMATIC DIAGRAMS / CBA’S AND TEST POINTS
Notes:
1. Do not use the part number shown on these draw-
ings for ordering. The correct part number is shown
in the parts list, and may be slightly different or
amended since these drawings were prepared.
2. All resistance values are indicated in ohms (K=10
3
,
M=10
6
).
3. Resistor wattages are 1/4W or 1/6W  unless other-
wise specified.
4. All capacitance values are indicated in 
µF
(P=10
-6
 
µF).
5. All voltages are DC voltages unless otherwise speci-
fied.
6. Electrical parts such as capacitors, connectors, di-
odes, IC's, transistors, resistors, switches, and fuses
are identified by four digits. The first two digits are
not shown for each component. In each block of the
diagram, there is a note such as shown below to
indicate these abbreviated two digits.
(Top View) (Bottom View)
(Bottom View)
Electrolytic Capacitor
+
Transistor or Digital Transistor
NPN Transistor
PNP Transistor
NPN Digital Transistor
PNP Digital
Transistor
(Top View)
(Top View)
E C B
E    C    B
Digital Transistor
CBA Symbols 
Schematic Diagram Symbols 
E C B
(Top View)
(Top View)
E C B
E C B
1-10-2
SC-FN2
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING
PAGES:
1. CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE FUSE.
2. CAUTION:
Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, first check to see that all components in the power supply circuit are not defective
before you connect the AC plug to the AC power supply.  Otherwise it may cause some components in the power
supply circuit to fail.
3. Note:
(1) Do not use the part number shown on the drawings for ordering.  The correct part number is shown in the parts
list, and may be slightly different or amended since the drawings were prepared.
(2) To maintain original function and reliability of repaired units, use only original replacement parts which are listed
with their part numbers in the parts list section of the service manual.
4. Wire Connectors
(1) Prefix symbol “CN” means “connector” (can disconnect and reconnect).
(2) Prefix symbol “CL” means “wire-solder holes of the PCB” (wire is soldered directly).
5. Voltage indications for PLAY modes on the schematics are as shown below:
2
3
1
 5.0
PLAY mode
5.0
Unit: Volts
Indicates that the voltage
is not consistent here.
6. How to read converged lines
1-D3
   Distinction 
Area
 Line 
Number
(1 to 3 digits)
 Examples:
  1. "1-D3" means that line number "1" goes to area "D3".
  2. "1-B1" means that line number "1" goes to area "B1".
 
3
2
1
A
B
C
D
1-B1
1-D3
AREA D3
AREA B1
7. Test Point Information
: Indicates a test point with a jumper wire across a hole in the PCB.
: Used to indicate a test point with a component lead on foil side.
: Used to indicate a test point with no test pin.
: Used to indicate a test point with a test pin.
Page of 64