XL-HP505
2 – 1
Audio
XL-HP505
Service Manual
XLHP505
Market
E
 
CHAPTER 2. 
ADJUSTMENTS
[1] ADJUSTMENT
1. MECHANISM SECTION
 Driving Force Check
 Torque Check
2. TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
 AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
 FM RF
Signal generator: 1 kHz, 40 kHz dev., FM modulated
 FM IF
Signal generator: 10.7MHz FM modulated
 Tape Speed
3. CD SECTION
Adjustment
Since this CD system incorporates the following automatic adjust-
ment functions, readjustment is not needed when replacing the
pickup. Therefore, different PWBs and pickups can be combined
freely.
Each time a disc is changed, these adjustments are performed
automatically. Therefore, playback of each disc can be performed
under optimum conditions.
Items adjusted automatically
1) Offset adjustment (The offset voltage between the head amplifier
output and the VREF reference voltage is compensated  inside  the
IC.)
*
Focus offset adjustment
*
Tracking offset adjustment
Torque Meter
Specified Value
Play: TW-2111
Over 80 g
Torque Meter
Specified Value
Play: TW-2111
30 to 80 g.cm
Fast forward: TW-2231
70 to 180 g.cm
Rewind: TW-2231
70 to 180 g.cm
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
AM IF
450 kHz
1,602 kHz
T351
*1
AM Band 
Coverage
531 kHz
(fL): T306
1.1 ± 0.1 V
*2
AM Tracking
990 kHz
990 kHz
(fL): T303
*1
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting 
Point
Instrument
Connection
FM Band 
Coverage
87.50 kHz
T301 (fL):
1.3 ± 0.1 V
*1
FM RF
98.00 MHz
(10-30 dB)
98.00 MHz
L312
*2
*1. Input: Antenna
Output: TP301
*2. Input: Antenna
Output: Speaker terminal
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting 
Point
Instrument
Connection
IF
10.7 MHz
98 MHz
T302
(Turn the 
core of trans-
former T302 
fully counter-
clock wise)
*1
*1. Input: Antenna
Output: TP301
Test Tape
Adjusting 
Point
Specified 
Value
Instrument 
Connection
Normal 
speed
MTT-111
Variable 
Resistor in 
motor.
3,000 ± 30 Hz
Speaker Ter-
minal (Load 
resistance: 6 
ohms)
Figure 1
Figure 2 ADJUSTMENT POINTS
TAPE MECHANISM
Tape
Motor
Variable Resistor in motor
AM
LOOP
ANTENNA
IC302
T351
T301
IC303
T303
T306
T302
L312
CNP301
SO302
IC301
TP302
TP301
AM TRACKING fL
AM BAND
COVERAGE fL
AM IF
FM RF
FM IF
FM OSC
FM ANTENNA
TERMINAL
TUNER PWB-C
20
R356
C393
XL-HP505
2 – 2
2) Tracking balance adjustment
3) Gain adjustment (The gain is compensated inside the IC so that the
loop gain at the gain crossover frequency will be 0 dB.)
*
Focus gain adjustment
*
Tracking gain adjustment
4. CD ERROR CODE DESCRIPTION
*
'CHECKING'
If Error is detected, 'CHECKING' will be displayed instead of 'ER-
CD**'. 'ER-CD**' display will only be displayed when error had been
detected for the 5th times.
Error
Explanation
01
When Pickup set inner position, inner switch cannot detect 
'ON' level for 10 secs.
10*
CAM error. Can't detect CAM switch when CAM is moving. 
11*
When it detect cam operation error during initialize process.
20*
TRAY error. Can't detect TRAY switch when TRAY is mov-
ing.
21*
When it detect TRAY operation error during initialize pro-
cess.
22*
When it detect invalid TRAY switch during normal operation.
31
When it change to CD function, DSP cannot read initial data.
XL-HP505
2 – 3
[2] TEST MODE
 Setting the test mode
During stand-by mode, press ON/STAND-BY button while pressing
down the 
button and X-BASS/DEMO button. then, press the CD
button to enter the test mode.
IL isn’t done
OPEN/CLOSE operation is using manual.
IL isn’t done
<<
>>,<<
>>buttons make pick's slide possible.
IL isn’t done
to page 2-4
<<PLAY>> key input.
C D
T E S T
A
Do TOC IL. Do normal play.
When these following key is input into PLAY key, track num-
ber can be appoint directly.
<<MEMORY>>
key input.
<<
1>> key: Track 4
<<
2>> key: Track 9
<<
3>> key: Track 15
Adjustment result automatically will
display as below for each 2 sec:
a) "FOF_XXXX"
b) "TOF_XXXX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
––––––––
<<STOP>> key input.
STOP
explanation:
a) Focus off set
= "FOF_XXXX"
b)Tracking off set
= "TOF_XXXX"
c)Tracking balance
= "TBAL_XX"
d)Tracking Gain
= "TGAN_XX"
f) Focus Gain
= "FGAN_XX"
g) RF level shift
= "RFLS_XX"
VOL — Last memory
P.GEQ — FLAT
X-BASS — OFF
To cancel : Power OFF
XL-HP505
2 – 4
Sliding the PICKUP with<<
>>, <<
>> button must only be
in STOP mode.
<<MEMORY>> key input.
Laser ON.
<<MEMORY>> key input.
Tracking OFF play at that specific point.
<<MEMORY>> key input.
Tracking ON play from that specific point.
<<MEMORY>> key input.
Adjustment result automatically will display as below for each 2 sec :
a) "FOF_XXXX"
b) "TOF_XXXX"
c) "TBAL_XX"
d) "TGAN_XX"
f) "FGAN_XX"
g) "RFLS_XX"
<<STOP>> key input.
STOP
explanation:
a) Focus off set
= "FOF_XXXX"
b)Tracking off set
= "TOF_XXXX"
c)Tracking balance
= "TBAL_XX"
d)Tracking Gain
= "TGAN_XX"
f) Focus Gain
= "FGAN_XX"
g) RF level shift
= "RFLS_XX"
VOL — Last memory
P.GEQ — FLAT
X-BASS — OFF