XL-60H/70H
TROUBLESHOOTING
When the CD does not function
When the CD section does not operate when the objective lens of the optical pickup is dirty, this section may not operate. Clean
the objective lens, and check the playback operation. When this section does not operate even after the above step is taken, check
the following items.
Remove the cabinet and follow the troubleshooting instructions.
"Track skipping and/or no TOC (Table Of Contents) may be caused by build up of dust other foreign matter on the laser pickup
lens. Before attempting any adjustment make certain that the lens is clean. If not, clean it as mentioned below."
Turn the power off.
Gently clean the lens with a lens cleaning tissue and a small amount of isopropyl alcohol.
Do not touch the lens with the bare hand.
Dust gradually accumulates on the objective lens during use, and it may degrade performance.  To avoid this problem, use a
cleaning disc designed for CD optical pickup lenses.
HOW TO USE
1. Using the brush in the cleaner cap, apply 1 or 2 drops of the cleaning fluid to the brush on the CD cleaner disc which has
the   mark next to it.
2. Place the CD cleaner disc onto the CD disc tray with the brush side down, then press the play button.
3. You will hear music for about 20 seconds and the CD player will automatically stop.  If it continues to turn, press the stop
button.
CAUTION
 The CD lens cleaner should be effective for 30~50 operations, however if the brushes become worn out earller then please
replace the cleaner disc.
 If the CD cleaner brushes become very wet then wipe off any excess fluid with a soft cloth.
 Do not drink the cleaner fluid or allow it to come in contact with the eyes.  In the event of this happening then drink and /
or rinse with clean water and seek medical advice.
 The CD cleaner disc must not be used on car CD players or on computer CD ROM drives.
 All rights reserved.  Unauthorized duplicating, broadcasting and renting this product is prohibited by law.
Cleaner Liquid
Cleaning Disc
PARTS CODE: UDSKA0004AFZZ
XL-60H/70H
– 38 –
Make sure that the disc is normal, and set the CD TEST MODE (STEP 1).
Is the measured voltage as specified in circuit diagram?
Check the main unit power supply circuit.
No
Yes
No
Is "Er-CD01" displayed"?
Yes
Move the pickup to most internal circumference side of disc.
Turn the power off and reset the CD TEST MODE (STEP 1).
Is "PU ERROR " not displayed?
Yes
Check the PWB pattern between pin 45 (CD RES) of IC701 and
pin 100 (/RST) of IC802.
No
Is +5V applied to pin 100 (/RST) of IC802?
Yes
Is CD Lid switch SW701
ON condition ?
No
Does the CD TEST MODE advance from "STEP 2"?
Yes
Check the between pattern IC701 and SW701 If OK.
Check the main unit power supply circuit.
No
Does the laser come on in CD TEST MODE "STEP 2"?
Check the procedure in "LASER FAILURE".
Yes
Does the CD TEST MODE advance from "STEP 3" to "STEP
4"?
Check the procedure in "FOCUS FAILURE".
Yes
Yes
Does the spindle motor rotate normally when the CD TEST
MODE changes from "STEP 4" to "STEP 3"?
Yes
Is the HF output on pin 38 of IC802 in CD TEST MODE "STEP 5"?
Check the procedure "HF ERROR".
Yes
No
No
No
No
Check the pattern between pin 57 (PUIN) of IC701 and BI803/
CNS803.
Check the between BI803/CNS803 and PU-IN switch.
Set ON condition the CD
Lid switch.
Check the procedure in "SPINDLE MOTOR CLV SERVO
FAILURE".
No
Does the sled motor
move ?
No
Does the sound heard when the optical pickup move to the
selected play by the FF/REW key.
Check the procedure "NO SOUND"
No
Yes
Check the procedure in
"SLED MOTOR
OPERATING FAILURE ".
Does the LCD track number and time indicator work properly ?
Check the pattern between IC701 and LCD701.
Yes
No
Is "Er-CD01 "
displayed ?
No
Turn the power off and then back on.
Does the unit initialize properly and start playback when PLAY
key is pressed?
Check the pattern between pin 57 (PUIN) of IC701 and
BI803/CNS803.
Check the between BI803/CNS803 and PU-IN switch.
No
Yes
Is "Er-CD01" displayed?
Check the procedure in "HF ERROR".
Yes
Yes
Does the unit play in order in the FF mode?
Check the procedure in "TRACK SEARCH FAILUR".
Yes
Does playback continue for 30 seconds after the start of
playback ?
Check the procedure in "SLED SERVO FAILURE".
Yes
Normal
No
No
Yes
– 39 –
XL-60H/70H
• Laser failure.
Is 0V applied to the pin 57 (SEL) of IC802 ?
Yes
No
Does the laser come on when pattern cut between pin 8 (SEL) of
IC801 and pin 57 (SEL) of IC802 ?
Check the PWB pattern between IC701 and IC802 (BUCK/CCE/
BUS0~3)
Yes
Yes
No
Check the peripheral parts of IC801 and Q801. If it is normal, the
optical pickup is faulty.
No
Check BI802/CNS802. If it is normal, the optical pickup is
faulty.
Is approx. 2V applied to the collector of Q801.
• Focus failure.
Does the optical pickup move up and down when the disc is
removed?
Is the following waveform ouput at the pin 43 (FEI) of IC802
when the disc is set?
Is the waveform shown above input at the pin 44 (SBAD) of
IC802?
Yes
Yes
No
No
The optical pickup is faulty.
Check as stated in item "FOCUS SERVO SAWTOOTH WAVE
FAILURE".
Yes
Check the periphery of IC801 and BI802/CNS802. Is it normal?
No
Check the pattern between pin 13 of IC801 and pin 44 of IC802.
Check the periphery of IC801 and BI802/CNS802.
IC801 is faulty.
Yes
Is +6.2V applied to the emiter of Q861 ?
Is +5V applied to the collector of Q861 ?
Yes
No
No
Check the PWB pattern between pin 16 of CNS602 and emiter of
Q861.
Check the peripheral parts of IC804 and Q861.
Is +5V applied to the pin 62 (VDD) of IC802 ?
Is +5V applied to the pin 1 (VCC) of IC801 ?
Yes
No
No
Check the PWB pattern between collector of Q861 and pin 62 of
IC802.
Check the PWB pattern between collector of Q861 and pin 1 of
IC801.
pin 43
(FEI)
pin 48
(FOO)
pin 44
(SBAD)
Yes
Yes
XL-60H/70H
– 40 –
• Focus servo sawtooth wave failure.
Is +6.2V applied to the pins 1 and 30 (VCC) of IC804 ?
 
Is sawtooh wave output to the pin 48 (FOO) of IC802 ?
IC802 is faulty.
No
Yes
Yes
Is sawtooth wave obtained between pins 25 and 26 of IC804 ?
No
No
Check the PWB pattern
between pin 2 of IC804
and pin 58 (CD STB) of
IC701.
Is +5V applied to the pin 2
(MUTE) of IC804 ?
Check the PWB pattern between pin 48 (FOO) of IC802 and pins
27 and 28 of IC804.  If OK.  IC804 is faulty.
Check the PWB pattern between pin 16 of CNS602 and IC804.
No
Is sawtooth wave obtained between pins 3 and 4 of BI801/
CNS801 ?  (as shown above)
Yes
Check the PWB pattern between BI801/CNS801 and IC804.
No
BI801/CNS801 connection failure or optical pickup failure.
Yes
• Spindle motor clv servo  failure.
Is above wave obtained between pins 5 and 6 of IC804 ?
Is following wave output to the pin 55 (DMO) of IC802 when
the CD TEST MODE "STEP 3" is changed to " STEP 4" ?
No
Yes
Check the procedure in "HF ERROR".
If OK.  IC802 is faulty.
Check the PWB pattern between pin 55 (DMO) of IC802 and pins
5 and 6 of IC804.  If OK.  IC804 is faulty.
No
Is above wave obtained between pins 5 and 6 of BI801/
CNS801 ?
Yes
Check the PWB pattern between BI801/CNS801 and IC804.
No
BI801/CNS801 connection failure or optical pickup failure.
Yes
DMO
Yes
1.5~2.5sec
1.5~2.5sec
Page of 6
Display

Sharp XL-60 (serv.man6) Service Manual ▷ Download

  • DOWNLOAD Sharp XL-60 (serv.man6) Service Manual ↓ Size: 61.6 KB | Pages: 6 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XL-60 (serv.man6) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XL-60 (serv.man6) System. Information contained in Sharp XL-60 (serv.man6) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.