DOWNLOAD Sharp XL-505E (serv.man5) Service Manual ↓ Size: 2.34 MB | Pages: 56 in PDF or view online for FREE

Model
XL-505E (serv.man5)
Pages
56
Size
2.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / System
File
xl-505e-sm5.pdf
Date

Sharp XL-505E (serv.man5) Service Manual ▷ View online

– 9 –
XL-505H,505E,507E/CP-505,505E,507
MECHANISM SECTION
• Driving Force Check
Torque Meter
Specified Value
Play: TW-2412
Over 80 g
• Torque Check
Torque Meter
Play: TW-2111
30 to 70 g. cm
Fast forward: TW-2231
50 to 140 g.cm
Rewind: TW-2231
50 to 140 g.cm
Specified
Value
Adjusting
Point
Instrument
Connection
Test Tape
MTT-111
In Motor
3,000 
±
Headphones
90 Hz
ADJUSTMENT
Specified Value
• Tape Speed
fL: Low-range frequency
fH: High-renge frequency
IF
450 kHz
1,620 kHz
T351
*1
 Band
522 kHz
(fL): T306
*2
Coverage
1.1 
±
 0.1 V
Tracking
990 kHz
990 kHz
(fL): T302
*1
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
Adjusting
Parts
Instrument
Connection
Display
Frequency
98.00 MHz
98.00 MHz
VR351*1
Input: CNP301
(25 dB
µ
V)
Output: Speaker
Terminal
Figure 9-1 ADJUSTMENT POINT
TUNER SECTION
TAPE MECHANISM
M901
Motor
Volume in motor
•  FM RF
Signal generator: 1 kHz, 75 kHz dev., FM modulated
Band
87.50 MHz
(fL): L303
*1
Coverage
3.4 
±
 0.1 V
RF
98.00 MHz
98.00 MHz
L302
*2
(10~30 dB)
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
*1. Input: Antenna,
Output: TP301
*2. Input: Antenna,
Output: Speaker Terminal
•  Detection
Signal generator: 10.7 MHz, FM sweep generator
IF
10.7 MHz
98.00 MHz
T304(Turn
Input: Pin 1 of
the core of
IC301
T304 fully
Output: TP302
counter-
clockwise.
Test
Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
*1. Input: Antenna,
Output: Speaker Terminal
*2. Input: Input is not connected,
Output: TP301
• Setting the Test Mode
Keeping the BAND button and MEMORY button pressed, turn
on POWER. Then, the frequency is initially set in the memory
as shown in Table. Call it with the 
,
 button to use it
for adjustment and check of tuner circuit.
Preset No.
FM
Preset No.
AM
1
87.50 MHz
6
522 kHz
2
108.00 MHz
7
1,620 kHz
3
98.00 MHz
8
603 kHz
4
90.00 MHz
9
1,404 kHz
5
106.00 MHz
10
990 kHz
11~40
•  FM Mute Level
Signal generator: 1 kHz, 40 kHz dev., FM modulated
Adjust so that an output signal appears.
Figure 9-2 ADJUSTMENT POINTS
CNP301
ANTENNA
MAIN PWB
L302
IC301
1
T302
TP301
TP302
T304
FM IF
AM IF
AM
TRACKING
T306
AM BAND
COVERAGE
FM MUTE
LEVEL
T351
VR351
L303
FM BAND
COVERAGE
FM RF
•  AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
XL-505H,505E,507E/CP-505,505E,507
– 10 –
Figure 10-1
Figure 10-2
1. This CD unit need adjustment as follow.
CD SECTION
Figure 10-3
CD Test Mode
Adjustment Part
Value/Adjusting Method
Instrument Connection
Step 1
VR803 (Focus Offset)
DC + 40 mV (FEL>RFO)
FEI (R826) and VRO
(1-Pin of TP801)
Step 4
VR802 (Tracking Error Balance)
*1 (See Fig. 10-1)
TSO (3-Pin of TP801)
and VRO (1 Pin of TP801)
*1: Adjust to obtaiin vertically symmetrical waveform (Fig. 10-1) with respect toreference DC level. The reference level is VRO
(Approx DC 2.1V).
2. This CD unit have the following automatic adjustment function. Automatic adjustment item.
2-1: Focus Servo Gain (Fig. 10-2)
Focus Gain Adjustment is performed when disc is changed.
2-2: Tracking Servo Gain (Fig. 10-3)
Tracking Gain Adjustment is performed when disc is changed and disc is playbacked.
TSO
VRO
1
SYMMETRICAL
UP AND DOWN
FET
FSO
1
2
TSO
TS2O
1
2
Figure 10-4 ADJUSTMENT POINTS
VR802
VR803
TP801
TRACKING
ERROR
BALANCE
FOCUS
OFFSET
T
S
O
N
C
V
R
O
321
3 2 1
CD SERVO PWB
– 11 –
XL-505H,505E,507E/CP-505,505E,507
TEST MODE
The Test Mode for this microcomputer has two variations, namely "regular Test Mode" for adjustment and measurement and "self-
diagnosis Test Mode" for self-judgment in final inspection of products.
1. Entering the Test Mode
To enter the each Test Mode, press the POWER key, holding down the following two keys in the regular standby mode (power
off state).  In this case only the main unit keys are valid.  The Test Mode is not set even when the remote controller POWER
key is turned on.
[Regular Test Mode]
1. CD  Test Mode (TEST 1)
2. Tuner Test Mode (TEST 3)
3. Electronic volume Test Mode (TEST 4)
4. Timer Test Mode (TEST 5)
5. LCD Test Mode (TEST 6)
[Self-diagnosis Test Mode]
1. Key input diagnosis TEST Mode (TESTA)
2. CD Test Mode (TEST 1)
1. Step 1 Mode
    When the CD Test Mode is set, the following display lights, and the CD pickup slides to the innermost periphery.
After lighting for 1.5 sec
When the following operation key is pressed in this state, the following operation is performed.
"POWER" ................ The Test Mode is set to off, power is turned off, and the mode is changed to the regular standby mode.
"FF/FWD" ................ After the pickup returns once to the innermost periphery, the pickup slides to the external periphery while
................................. this key is held down.
"REW/REV" ............. After the pickup returns once to the innermost periphery, the pickup slides to the internal periphery while
................................. this key is held down.  However, input is invalid if PU-IN is on.
"PLAY" ..................... Shift to Step 2
"STOP" .................... Invalid
* In case of mode entry the pickup is moved to the internal periphery.  At this time entry of any key other than POWER key is
disabled until shift of pickup to the internal periphery is completed.  If PU-IN SW ON cannot be detected while waiting for 10
seconds, the slide motor is stopped, the following error is displayed, and entry of any key other than POWER key is disabled.
XL-505H,505E,507E/CP-505,505E,507
– 12 –
2. Step 2 Mode
    When the PLAY key is pressed in the mode above, the laser lighting is turned on.  In this state the laser is only turned on,
    and other operations are not performed.
When the following operation key is pressed in this state, the following operation is performed.
"POWER" ................ The Test Mode is set to off, power is turned off, and the mode is changed to the regular standby mode.
"FF/FWD" ................ While this key is held down, the pickup slides to the external periphery.
"REW/REV" ............. While this key is held down, the pickup slides to the internal periphery.  However, if PU-IN is on, entry is
................................. invalid.
"PLAY" ..................... Shift to Step 3
"STOP" .................... Return to Step 1
3. Step 3 Mode
While the laser is lighting, the focus servo is turned on, and focus search is performed.  If focusing failure occurs, focus search
is repeated until focusing is attained.
When the following operation keys are pressed in this state, the following operations are performed.
"POWER" ................ The Test Mode is set to off, power is turned off, and the mode is changed to the regular standby mode.
"FF/FWD" ................ While this key is held down, the pickup slides to the external periphery.
"REW/REV" ............. While this key is held down, the pickup slides to the internal periphery.  However, if PU-IN is on, entry is
................................. invalid.
"PLAY" ..................... If focusing has been attained, the process proceeds to Step 4.  Unless focusing has been attained,
................................. reception is inhibited.
"STOP" .................... Return to Step 1
4. Step 4 Mode
The disc is rotated and CLV is locked while the tracking servo is off.
The time display indicates always "0:00".
When the following operation keys are pressed in this state, thefollowing operations are performed.
"POWER" ................ The Test Mode is set to off, power is turned off, and the mode is changed to the regular standby mode.
"FF/FWD" ................ While this key is held down, the pickup slides to the external periphery.
"REW/REV" ............. While this key is pressed, the pickup slides to the internal periphery.  However, if PU-IN is on, entry is
................................. invalid.
"PLAY" ..................... Shift to Step 5
"STOP" .................... Return to Step 1
Page of 56
Display

Click on the first or last page to see other XL-505E (serv.man5) service manuals if exist.