QT-CD111H/110H
– 19 –
TROUBLESHOOTING (CD SECTION)
When the CD does not function
When the CD section does not operate When the objective lens of the optical pickup is dirty,this section may not operate.Clean
the objective lens,and check the playback operation.When this section does not operate even after the above step is taken,check
the following items.
Remove the cabinet and follow the troubleshooting instructions.
"Track skipping and/or no TOC(Table Of Contents) may be caused by build up of dust other foreign matter on the laser pickup lens.
Before attempting any adjustment make certain that the lens is clean. If not, clean it as mentioned below."
Turn the power off.
Gently clean the lens with a lens cleaning tissue and a small amount of isopropyl alcohol.
Do not touch the lens with the bare hand.
See if the pick-up is in the pick-up in SW702 position.
If the items mentioned above are OK, check the main
microcomputer IC701.
Yes
Yes
•  The CD function will not work.
The CD operating keys don't work.
Check the CD, DPS microcomputer (IC701), power supply, 4.19
MHz and 16.93 MHz clock, and reset terminal.
Check the waveform of SCK, SO (DATA) and SI (COMM).
Yes
Yes
Playback can be performed without a disc.
Yes
Does the output waveform of IC801(16)(FD) match that shown in
Fig. 19?
Check the area around IC804-BI801/CNS801.
Yes
Check the IC801(50)(CLK) line, 4MHz.
Check the microcomputer data on pins (51)(CL), (52)(DAT) and
(53)CE.
Figure 19
•  The CD operating keys work.
No
Yes
No
Does the pick-up move up and down twice?
Focus search OK.
Focus search
is performed
two times
when play
operation is
done without
disc.
  0.5s
0.50 V
IC801  16  FD
2
1
  0.5s
0.50 V
IC801  15  TD
Check the Focus - HF system.
QT-CD111H/110H
– 20 –
Check the laser diode driver.
•  Playback can only be performed when a disc
is loaded.
Does the DRF signal change from "L" to "H"?
No
If the disc is not turning, the DRF
should not change to "H".
Is HF waveform normal (see the Fig. 20-1, 2)?
Yes
 
Is the Focus servo active? (Can you hear it working?)
No
Check the area around IC801(16) - (21) (focus servo circuit).
L
evel is abnormal.
Check the periphery
of IC801 pins 41 and
42.
No
Waveform is unstable.
Check the spin
system.
Yes
Yes
Yes
Yes
Yes
Figure 20-2
Figure 20-1
Check the spin
system.
HF
0.1V/DIV
0.5µsec/DIV(DC)
(When playing
 back the disc)
Waveform in case
of normal play-
back
3
2
1
4
  0.5s
1.00 V
IC801  16  FD
  0.5s
10.0 V
IC801  12  CLV+
  0.5s
10.0 V
IC801  54  DRF
  0.5s
2.00 V
IC801   7   TE
Check the tracking system.
•  Check the tracking system.
Check waveform of IC801 pin 7 (TE).
Check the periphery of IC801
pin 8 to pin 15, and IC804 to
BI801/CNS801.
Tracking servo is inoperative.
The waveform shown in Fig. 20-3
appears, and no-disc state appears
soon.
Yes
Yes
Yes
Yes
Play is possible in
TEST mode.
Although IL is possible,
play is impossible.
Normal jump is impeded, and the
program top cannot be reached.
Check the periphery of
IC801 pin 14.
Yes
Data  cannot be read.
Check the VCO-PLL system.
Yes
3
4
  5ms
1.00 V
IC801   7   TE
  5 ms
5.0 V
IC801  54  DRF
Figure 20-3
QT-CD111H/110H
– 21 –
The turntable fails to rotate or rotates at high speed.
Yes
Check the periphery of IC801 pins 23 to 27, pin 39 and pin 40,
IC802 pin 12 and pin 13, IC804 to BI803/CNS803.
The turntable rotates a little.
Yes
The spin driver circuit is normal.
No
Yes
Check the IC801 pins 43 and 44, IC802 pins 3, 5, 7, 9 and 10.
Error
Yes
Check PDO waveform (Fig. 21).
Play operation is performed when disc exits.
Yes
Although HF waveform is normal, TOC data cannot be read.
Figure 21
2
3
  0.5s
1.00 V
IC802   3   PDO
  0.5s
1.00 V
IC801  16   FD
As VCO freque-
ncy is locked at
4.32 M Hz,
voltage of PDO
rises and stabili-
zes.
Stop --> Play
Check IC802 pins 37and 40.
Check the periphery of IC803 (OPAMP).
Abnomal
Usually, the number of pulses of flawless disc is 100 pulses/sec
or less.
No
Yes
Check  IC802 pin 48 (EFLG).
•  Although HF waveform is normal and the time
indication is normal, no sound is emitted.
Display

Sharp QT-CD111H (serv.man9) Service Manual ▷ Download

  • DOWNLOAD Sharp QT-CD111H (serv.man9) Service Manual ↓ Size: 131.65 KB | Pages: 3 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp QT-CD111H (serv.man9) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp QT-CD111H (serv.man9) Portable. Information contained in Sharp QT-CD111H (serv.man9) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.