DOWNLOAD Sharp DK-A10H (serv.man3) Service Manual ↓ Size: 13.25 MB | Pages: 82 in PDF or view online for FREE

Model
DK-A10H (serv.man3)
Pages
82
Size
13.25 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / System
File
dk-a10h-sm3.pdf
Date

Sharp DK-A10H (serv.man3) Service Manual ▷ View online

DK-A10H/DK-A10H(BK)
2 – 2
[4] Tuner Test
a) Unit will Power On in TUNER function.
b) Preset will be writen as shown below for each destination
ΰFM MONO BAND α
c) Receiving Preset No. 1
d) End TEST mode if POWER key is press
ΰ All preset will be deleted α.
e) VOLUME setting is 25.
Reference
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
 SPAN
μDisplayν
At Tuner function only "FM" or "AM" will blinking during Test Mode.
EUROPE
Destination
TUNER PRESET MEMORY
[5] CD Test
1. Mode Outline
It is possible to read setting value after Auto Adjustment(to judge between initial value) 
To force movement of pick-up 
Inner Move, Outer Move, LD ON/OFF
To display accumulate error total for 10sec while PLAY(about 750frame at normal)
(For this model it is not count by Frame Method, but 10sec timer Accumulated Error Total
and not related Frame total)
4 x CLV trace but, no sound output.
2. IN CD Test Mode
1) Direct POWER ON in CD function.
2)  Execute initial process to DSP.
3)  Send command correspondence to key.
Valid key 
Κ PLAY/PAUS EΕSTOPΕSKIP-UP/CUE ΕSKIP-DWN/REV Ε
POWER
ΕDISPLAYΕVOL UP/DWN ΕCD EJECT ΕCD
Additional
ΚIf which one of KEY1 + KEY2 press together All FL segment will light up.
.
KEY_2-6_
CLOCK DISPLAY "0:00”
SUMMER TIME COMFIRMATION
CLOCK
KEY_1-6_ + BUZZER 2
(B pattern VOLUME25
α
KEY_1-7_ + BUZZER 3
(B pattern VOLUME25
α
CD
iPod
KEY NAME
ALARM ON/OFF
ALARM
KEY
TEST MODE
DISPLAY
KEY_1-5_ + BUZZER 1
(B pattern VOLUME25
α
KEY_2-1_
KEY_2-2_
KEY_2-3_
KEY_2-4_
KEY_2-5_
TUNER
AUX
SNOOZE/DIMMER
KEY_1-2_
KEY_1-3_
KEY_1-4_
KEY
TEST MODE
DISPLAY
KEY_1-1_
REVIEW
PLAY/PAUSE
KEY NAME
E SOUND
VOL UP
VOL DOWN
CD EJECT
KEY_3-1_
KEY_2-7_
KEY NAME
KEY
TEST MODE
DISPLAY
EQ
CUE
87.50 108.00  90.00 106.00  98.00  522K  1620K  603K 1404K  990K  50K/9K
DK-A10H/DK-A10H(BK)
2 – 3
4. Read Error Total
By pressing DISPLAY key while PLAY, will display Accumulate Error Total for 10sec time
(about 750frame at normal)
Read Method
1.  Send PRCSET (9188) command EC/FC=H
2.  Observe BUS2 while in idle mode, If become "H"(Sub-CODE read possible)
     by (SRC6) read command Error Total for 1 frame are read.
3.  This process will repeat for every 10sec, the value will be display. And renew for every 10sec.
4.  While displaying ERR, if Display key input detected it will return to TEST MODE normal display.
Additional
1.   STEP No. is, ”0” 
Д “5”. ”0” is STOP condition.
2.   Adjustment Value Read or Error Total Read are display on FL.
Read Error Total 
Κ “ҟҠϵҡҮҮϵϠϠϠϠ”
ϠϠϠϠ”is Error Total
A.   PLAY/PAUSE
ΚCD operation by steps
STEP1
ΚPLAY/PAUSE key from STOP condition,  LD ON
STEP2
ΚPLAY/PAUSE key from STEP1 condition,  FOCUS ON
STEP3
ΚPLAY/PAUSE key from STEP2 condition,  CLV SERVO ON
STEP4
ΚPLAY/PAUSE key from STEP3 condition,  Tracking Servo ON
STEP5
ΚPLAY/PAUSE key from STEP4 condition,  Read and Display Sub-CODE
Ϡ by pressing PLAY/PAUSE key over 1sec, direct go to STEP5.
B.   STOP
ΚPLAY condition to STOP(each step go to STOP )
RESET display
ΰwhile display coefficient α
C.   SKIP-UP/CUE
ΚForce to move Pick-UP FWD direction
D.   SKIP-DWN/REV
ΚForce to move Pick-UP REV direction
If PU_IN_SW ON, slide will STOP.
E.   CD
ΚOnly recognize long press, Execute Auto AdjustΰAt now Pick-UP position
α
F.   POWER
ΚEnd Test Mode
G.   DISPLAY
ΚWhile CD STOP, Read Coefficient Register
While CD PLAY, Error Total display
H.   VOL-UP/DWN
ΚNormal VOLUMEControl.
I. CD EJECT
: While STOP (After go to STOP from each step), CD EJECT process.
J. E SOUND
: While STOP toggle between 2x mode  ←→ 1x mode.
  BASS indicator ON while 2x mode.
3. Read Adjustment Value
By pressing DISPLAY key while STOP, begin read below items.
Pressing STOP key, return to Normal Display.
ITEMS
DISPLAY
Κ“ ”IS BLANK,“ҴҴ”IS ADJUST VALUE or READ VALUE
Focus Balance
ҢҞΚҴҴ
Focus Gain
ҢңΚҴҴ
Tracking Balance
ҰҞΚҴҴ
Tracking Gain
ҰңΚҴҴ
Focus OFFSET
ҢҫҢҢΚҴҴ
Tracking OFFSET
ҰҫҢҢΚҴҴ
RFRP
ҮҢҮҬΚҴҴ
Focus Error(RW judge)
ҮҳΚҴҴҴҴҴҴ
Focus Error(not RW judge)
ҠҝΚҴҴҴҴҴҴ
Setting register by D4XX(FTBAST) after, read register by 2XX(SRC2)
DK-A10H/DK-A10H(BK)
2 – 4
[8] EEPROM Writing Mode
A Test Mode to apply improvement patch if happen bug in Micom Mask IC, 
 1.Test Mode Operation
a) POWER ON in display porpose Power ON.
b) Check port setting, if set to EEPROM exist, go to EEPROM write standby condition. 
c) DATA being send from PC using RS232C port, DATA will be transfer to EEPROM. 
d) After finished transfer, EEPROM writing port will be set to write prohibit.
e) By pressing POWER key test mode end and RESET process will be execute.
CONDITION
LED CONT 1/2  ALARM LED
READY TO RECEIVE DATA
ON
ON
WRITING
BLINK
OFF
WRITING END
ON
OFF
WRITING ERROR
OFF
BLINK
[6] Test Mode for Writing Micom Software (FLASH IC) 
1. CD-R Writing Mode
  It possible to write software to FLASH using CD-R. This Test Mode is to set enviroment 
  for writing process.
System MICOM will POWER ON in CD function.
SYS Side
Κ
Ѿα Enter "ROMCF____" and display will show“FLASH_WR_”.
ѿα Load CD-R that only being copy with *.MOT file.
Ҁα Unit will automatically enter UPDATE Mode after reading DATA.
ҁα SNOOZE_LED will blink during Writing Process.
҂α After succeed writing SNOOZE_LED will light up.
҃α If error happen ALARM_LED will start blinking.
҄α Take out DISC after the DISC EJECTED.
҅α RESET will be display due to POWER key press if writing process succeed.
҆α Test Mode end without reseting for error writing if POWER key pressed.
[7] Test Mode for Writing EEPROM Patch
1. CD-R Writing Mode
  It possible to write PATCH to EEPROM using CD-R. This Test Mode is to set enviroment 
  for writing process.
System MICOM will POWER ON in CD function.
SYS Side
Κ
Ѿα Enter ROMCE and display will show “EEPROM_WR”.
ѿα Load CD-R that only being copy with *.MOT file.
Ҁα Unit will automatically enter UPDATE Mode after reading DATA.
ҁα LED CONT1/2 will blink 1Hz during Writing Process.
҂α After succeed writing LED CONT1/2 will light up.
҃α If error happen ALARM_LED will start blinking 2Hz.
҄α Unit will Automatically RESET, if writing process succeed.
҅α RESET will be display due to POWER key press if writing process fail.
DK-A10H/DK-A10H(BK)
2 – 5
[9] User Reset
No.
USER RESET
1
 ALL 
CLEAR(RESET)
[10] ALL Clear ( Reset )
Function                            :
  Software RESET
                                   :
All the function
                                   :
After display "CLEAR ALL", power will off.
                                   :
Initial condition set for iPod
"CLEAR_ ALL" shown at display
Direct Access
POWER + SNOOZE/DIMMER + iPod MODE
Page of 82
Display