CD-E110H
– 10 –
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
•••••     
 AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
AM IF
450 kHz
1,620 kHz
T351
*1
AM Band
522 kHz
(fL): T306
*2
Coverage
1.1 
±
 0.1 V
AM Tracking 990 kHz
990 kHz
(fL): T302
*1
ADJUSTMENT
Adjusting
Parts
Display
Frequency
• FM Mute Level (FM ST MODE)
Signal generator: 1 kHz, 40 kHz dev., FM modulated
*1. Adjust so that an output signal appears.
98.00 MHz
98.00 MHz
VR351*1
Input:CNP301
(26 dB
µ
V)
Output: Speaker
Terminal
Instrument
Connection
•  FM IF
Notes:
1. Description of the "FM IF Adjustment" is not carried on this
Manual. It is because the IF coil in the FM front end section
has been best adjusted in the factory so that its further
adjustment is not needed at the field. When replacing the
FM front end assembly, no adjustment is needed either.
2. The parts in the FM front end section are prepared in a
complete unit, so you can't obtain each part individually.
MECHANISM SECTION
•••••
 Driving Force Check
Torque Meter
Specified Value
Play: DM-300
Tape 1: Over 80 g
Tape 2: Over 80 g
•••••
 Torque Check
Torque Meter
Tape 2
Play: DM-300
10 to 20 g.cm
10 to 20 g.cm
Fast forward: DM-300
Over 50 g.cm
Rewind: DM-300
Over 50 g.cm
Specified Value
Tape 1
Specified
Value
Adjusting
Point
Instrument
Connection
Test Tape
Tape
TCC-119
Variable
3,000 
±
 30 Hz
Speaker
speed
Resistor in
Terminal
motor.
(Load
resistance:
8 ohms)
•••••
 Tape Speed
Figure 10-1
Tape
Motor
Variable Resistor in Motor
TAPE MECHANISM
VR351
FM MUTE
Level
T351
AM IF
T302
T306
IC302
CNP301
FE301
SO301
AM BAND
COVERAGE fL
AM TRACKING
fL
MAIN PWB
1
11
12
22
20
R381
R356
R357
TP301
TP302
Figure 10-2 ADJUSTMENT POINTS
Display

Sharp CD-E110 (serv.man9) Service Manual ▷ Download

  • DOWNLOAD Sharp CD-E110 (serv.man9) Service Manual ↓ Size: 14.19 KB | Pages: 1 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp CD-E110 (serv.man9) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp CD-E110 (serv.man9) System. Information contained in Sharp CD-E110 (serv.man9) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.