– 9 –
CD-E100H
CD-E100E
Test Stage
Frequency
Frequency
Display
Setting/
Adjusting
Parts
Instrument
Connection
•••••     
 AM IF/RF
Signal generator: 400 Hz, 30%, AM modulated
*1. Input: Antenna
Output: TP302
*2. Input: Antenna
Output: TP301
TUNER SECTION
fL: Low-range frequency
fH: High-range frequency
AM IF
450 kHz
1,620 kHz
T351
*1
AM Band
522 kHz
(fL): T306
*2
Coverage
1.1 
±
 0.1 V
AM Tracking 990 kHz
990 kHz
(fL): T302
*1
Figure 9-2 ADJUSTMENT POINTS
ADJUSTMENT
MECHANISM SECTION
•••••
 Driving Force Check
Torque Meter
Specified Value
Play: TW-2111
Tape 1: Over 80 g
Tape 2: Over 80 g
•••••
 Torque Check
Torque Meter
Tape 2
Play: TW-2111
30 to 80 g.cm
30 to 80 g.cm
Fast forward: TW-2231
70 to 180 g.cm
Rewind: TW-2231
70 to 180 g.cm
Specified Value
Tape 1
Specified
Value
Adjusting
Point
Instrument
Connection
Test Tape
Tape
MTT-111
Variable
3,000 
±
 30 Hz
Speaker
speed
Resistor
Terminal
(Load
resistance:
6 ohms)
•••••
 Tape Speed
Figure 9-1
Tape
Motor
TAPE MECHANISM
Variable Resistor
FM IF
FM RF
VR351
FM MUTE
Level
T351
AM IF
T302
T306
T304
IC301
IC302
L303
L302
CNP301
FM BAND
COVERAGE fL
AM BAND
COVERAGE fL
AM TRACKING
fL
MAIN PWB
1
1
11
12
22
20
R381
R356
R357
TP301
TP302
Adjusting
Parts
Display
Frequency
• FM Mute Level (FM ST MODE)
Signal generator: 1 kHz, 40 kHz dev., FM modulated
*1. Adjust so that an output signal appears.
98.00 MHz
98.00 MHz
VR351*1
Input:CNP301
(26 dB
µ
V)
Output: Speaker
Terminal
Instrument
Connection
*1. Input: Antenna
Output: TP301
*2. Input: Antenna     Output: Speaker Terminal
•••••
  FM RF
Signal generator: 1 kHz, 75 kHz dev., FM modulated
FM Band
87.50 MHz
L303 (fL):
*1
Coverage
3.4 V 
±
 0.1 V
FM RF
98.00 MHz 98.00 MHz
L302
*2
(10-30 dB)
Test Stage
Instrument
Connection
Frequency Frequency
Display
Setting/
Adjusting
Point
•••••
  FM IF
Signal generator: 10.7 MHz, FM modulated
IF
10.7 MHz
98 MHz
T304
*1
(Turn the
core of trans-
former T304
fully counter-
clock wise)
Test Stage
Instrument
Connection
Frequency Frequency
Display
Setting/
Adjusting
Point
*1. Input: Antenna
Output: TP301
Display

Sharp CD-E100 (serv.man8) Service Manual ▷ Download

  • DOWNLOAD Sharp CD-E100 (serv.man8) Service Manual ↓ Size: 16.57 KB | Pages: 1 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp CD-E100 (serv.man8) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp CD-E100 (serv.man8) System. Information contained in Sharp CD-E100 (serv.man8) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.