AUDIO TECHNICAL BULLETIN
Page 1 of 1
MODELS
CDC250H
CDC260H
SYMPTOM Display lamp goes open circuit for no apparent reason.
CAUSE
Supply voltage level variations.
ACTION
Change R917 from 10R to 15R.  Note that this resistor is 0.5W.
Display

Download Sharp CD-C260H (serv.man8) Technical Bulletin

Here you can view online or download Sharp CD-C260H (serv.man8) Technical Bulletin in pdf. This Technical Bulletin can help you recover, restore, fix, disassemble and repair Sharp CD-C260H (serv.man8) System. Information contained in Sharp CD-C260H (serv.man8) service manual (repair manual) typically includes: