DOWNLOAD Sharp AY-XP13CR (serv.man15) Service Manual ↓ Size: 4.26 MB | Pages: 48 in PDF or view online for FREE

Model
AY-XP13CR (serv.man15)
Pages
48
Size
4.26 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ay-xp13cr-sm15.pdf
Date

Sharp AY-XP13CR (serv.man15) Service Manual ▷ View online

1
AY-XP08CR
AY-XP10CR
AY-XP13CR
INDOOR UNIT
AY-XP08CR
AY-XP10CR
AY-XP13CR
SPLIT TYPE
ROOM AIR CONDITIONERS
In the interests of user-safety (Required by safety regulations in some
countries)  the set should be restored to its original condition and only parts
identical to those specified should be used.
Page
SPECIFICATIONS .............................................................................................................................................  2
EXTERNAL DIMENSIONS ................................................................................................................................. 3
WIRING DIAGRAMS .........................................................................................................................................  5
ELECTRICAL PARTS ......................................................................................................................................... 9
BLOCK DIAGRAM ............................................................................................................................................ 10
MICROCOMPUTER CONTROL SYSTEM ....................................................................................................... 12
FUNCTIONS ....................................................................................................................................................  17
FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES ...............................................................  27
BREAKDOWN DIAGNOSIS PROCEDURE ....................................................................................................  29
REFRIGERATION  CYCLE .............................................................................................................................  32
PERFORMANCE CURVES .............................................................................................................................  33
DISASSEMBLING PROCEDURE ....................................................................................................................  34
OPTION ...........................................................................................................................................................  41
REPLACEMENT PARTS LIST ......................................................................................................................... 43
TABLE OF CONTENTS
MODELS
OUTDOOR UNIT
AE-X08CR
AE-X10CR
AE-X13CR
New Refrigerant : R-410A
SERVICE MANUAL
SHARP CORPORATION
S5302AYXP13CR
2
AY-XP08CR
AY-XP10CR
AY-XP13CR
MODEL
INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT
      ITEMS
AY-XP08CR AE-X08CR AY-XP10CR AE-X10CR AY-XP13CR AE-X13CR
Cooling capacity(Min. Max.) 
kW
2.2(0.9 _ 2.7)
2.8(0.9 _ 3.3)
3.6(0.9 _ 4.0)
Heating capacity(Min.~Max.) 
kW
3.2(0.9 _ 3.6)
3.7(0.9 _ 5.0)
4.8(1.0 _ 6.2)
Moisture removal(at cooling) 
Liters/h
0.6
0.7
1.2
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
220 - 240
Cool
A
3.4 - 3.1
4.3 - 4.0
5.5 - 5.1
Rated current 
Heat
A
4.2 - 3.9
4.9 - 4.5
6.8 - 6.2
Cool
W
730
930
1200
Rated input 
Heat
W
 910
1050
1480
Cool
%
98 - 98
98 - 97
99 - 98
Power factor 
Heat
%
98 - 97
 97 - 97
99 - 99
Type
Hermetically sealed rotary type
Compressor
Model
DA89X1F-20F
Oil charge
Ester oil VG68 370ml
Evaporator
Louvre Fin and Grooved tube type
Refrigerant system Condenser
Corrugate Fin and Grooved tube type
Control
Capillary tube
Refrigerant volume
750g
770g
870g
(R-410A)
De-lce system
 Micro computer controled reversed systems
Noise level
High
dB(A)
33
43
36
43
38
48
(at cooling)
Med.
dB(A)
29
32
33
-
Low
dB(A)
27
27
29
-
Fan system
Drive
Direct drive
Air flow quantity
High
m
3
/min.
7.5
28
9.8
27.7
9.4
30
 (at cooling)
Med.
m
3
/min.
6.5
8.0
8.0
Low
m
3
/min.
5.1
6.0
6.5
Fan
Cross flow fan Propeller fan Cross flow fan Propeller fan Cross flow fan Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
 3/8", 1/4"
Drain piping mm
O.D  ø 18
Others
Compressor: Compressor thermistor
Safety device
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Width
mm
815
780
815
780
815
780
Net dimensions
Height
mm
278
540
278
540
278
540
Depth
mm
198
269
198
269
198
269
Net weight
kg
9
33
10
33
10
37
 Note: The condition of star " 
 
" marked item are ‘ISO5151’ : 1994(E), condition T1.
SPECIFICATIONS
3
AY-XP08CR
AY-XP10CR
AY-XP13CR
EXTERNAL DIMENSIONS
Figure E-1. INDOOR UNIT
Figure E-2. OUTDOOR UNIT
815
278
198
1100
Length unit (mm)
22.0
58
CRMC-A442JBE0
R03(AAA) 2PCS.
SHARP CORPORATION
INVERTER AIR CONDITIONER
18.5
175
269
179.5
182.5
136
81
780
70
540
310
335
540
12
37.5
4.5
58
158
16
4
AY-XP08CR
AY-XP10CR
AY-XP13CR
Figure E-3. INSTALLATION DIMENSIONS
815 (unit size)
More than 50mm
E
Center of wall hole:
Leftward piping
Center of wall hole: Backward piping
Outline of indoor unit
55
95
80
55 
A
I
F
E
D
D
F
A
C
J
H
I
G
B
21
278 (unit size)
38
Ceiling
E
Page of 48
Display

Sharp AY-XP13CR (serv.man15) Service Manual ▷ Download

  • DOWNLOAD Sharp AY-XP13CR (serv.man15) Service Manual ↓ Size: 4.26 MB | Pages: 48 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AY-XP13CR (serv.man15) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AY-XP13CR (serv.man15) Air Conditioner. Information contained in Sharp AY-XP13CR (serv.man15) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.