DOWNLOAD Sharp AY-X095 Service Manual ↓ Size: 340.07 KB | Pages: 32 in PDF or view online for FREE

Model
AY-X095
Pages
32
Size
340.07 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ay-x095.pdf
Date

Sharp AY-X095 Service Manual ▷ View online

13
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
Unused
Fan speed adjust (10 to 12)
Fan speed adjust (6 to 9)
Fan speed adjust (1 to 5)
Blower temperature compensation
Unused
Outdoor rating (heater)
Outdoor rating (cooler)
GND
Oscillator (8 MHz)
Oscillator (8 MHz)
Reset
Buzzer
Serial in
Serial out
Preheat switch
Wireless switch
Model select 7
Model select 6
Model select 5
Fan speed
Unused
Unused
+5V
Power supply clock
GND
SCL (E
2
PROM)
SDA (E
2
PROM)
Unused
GND
NC
GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
P53
P52
P51
P50
P33
P32
P31
P30
AGND
CK
2
CK
1
RESET
F
P46
P45
P44
P43
P42
P41
P40
KH
P66
P65
P64
P63
GND
P62
P61
P60
OSC
IN
OSC
OUT
TEST
Input
Input
Input
Input
Input
Input
Input
Input
Input
Output
Input
Input
Output
Input
Output
Input
Input
Input
Input
Input
Input
Output
Output
Input
Input
Input
Output
In/output
Input
Input
Output
Input
Port
No.
Port
name
Input/
Output
CPU Port Allocation
Application
14
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
Model select 4
Model select 3
Model select 2
Model select 1
Auxiliary mode switch (push switch)
Unused
Power on
Unused
Wireless signal
Run LED
Timer LED
Unused
Unused
Unused
Main relay
Unused
Fan gate signal
Louvre motor
Louvre motor
Louvre motor
Louvre motor
Unused
Unused
Unused
Unused
GND
+5 V
+5 V
Test (?)
Indoor temperature thermo
Indoor heat exchanger thermo
Unused
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
P27
P26
P25
P24
P23
P22
P21
P20
KI
P17
P16
P15
P14
P13
P12
P11
P10
P07
P06
P05
P04
P03
P02
P01
P00
GND
V
SS
V
R
P57
P56
P55
P54
Input
Input
Input
Input
Input
Input
Input
Input
Input
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Input
Input
Input
Input
Input
Input
Input
Port
No.
Port
name
Input/
Output
Application
15
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
System Block Diagram / Function Diagram
AE-X095E, AE-X075E, AU-X095E, and AU-X075E
Outdoor
CPU
Test mode circuit
LED drive circuit
Winter kit circuit (option)
Heat exchanger thermo
circuit
Compressor thermo circuit
CPU reset circuit
Serial I/O circuit
IPM drive circuit
4-way valve relay drive
circuit
Outdoor fan relay drive
circuit
Power supply
circuit (built
into IPM)
CPU oscillator circuit
AC overcurrent detection
circuit
DC overcurrent detection
circuit
Outdoor temperature thermistor (option)
Heat exchanger pipe thermistor (option)
LED
Heat exchanger
thermistor
Compressor thermistor
Current transfer
Compressor
IPM
4-way valve (except for
the AU-X095E/X075E)
Outdoor fan
Smoothing
circuit
Active filter
circuit
Filter
circuit
Unit-unit
wiring (AC
power and
serial
signals)
13 A
protection
3 A
protection
10 A protection
16
AH-X075E/X095E
AU-X075E/X095E
AY-X075E/X095E
AE-X075E/X095E
Internal Oscillator Circuit
This is an internal oscillator circuit to operate the CPU IC1 itself. The externally mounted ceramic oscillator, ceramic
condenser and resistor yield a stable 8.00 MHz oscillation. The ceramic capacitor is built into OSC1.
Outdoor Unit Control Circuit Operation
The outdoor unit control circuit is composed of an electronic control circuit centered around the outdoor control PCB
and an inverter for generating the voltage applied to the compressor.
The outdoor control PCB is constructed around a CPU. It receives the serial signals sent by the indoor unit, and
generates various corresponding signals in response. At the same time, it provides additionalcontrol for the outdoor unit
itself, resulting in overall control of the air conditioner.
The inverter controls the frequency of the compressor rotation. It operates the IPM according to the control signals sent
by the outdoor control PCB. The PWM method allows free control of the frequency and voltage, giving a wide range of
performance variations.
Model Switching Circuit
The 5V voltage is divided across R46 and R47 and the analog voltage is input to CPU IC1 pin 8. The CPU converts the
analog voltage to a digital value using an internal AD conversion circuit to select from among 8 models.
5V
R46
R47
CPU (IC1) pin 8
OSC
CPU (IC1) pin 10
CPU (IC1) pin 11
Page of 32
Display

Click on the first or last page to see other AY-X095 service manuals if exist.