AH-A07BE/09BE/12BE
AY-A07BE/09BE/12BE
AU-A07BE/09BE/12BE
AE-A07BE/09BE/12BE
13
Fig. L-4 Printed Wiring Diagram for AH-A07BE/A09BE/A12BE
FROM 
TERMINAL 
BOARD
(POWER) " 1 "
FROM 
TERMINAL 
BOARD
(UNIT) " 1 "
FROM 
TERMINAL BOARD
(UNIT) " N "
FROM 
THERMISTOR
FROM 
LOUVER
(UPPER)
FROM 
LOUVER
(LOWER)
INDOOR 
FAN MOTOR
(R.P.M. SIGNAL)
INDOOR 
FAN MOTOR
14
AH-A07BE/09BE/12BE
AY-A07BE/09BE/12BE
AU-A07BE/09BE/12BE
AE-A07BE/09BE/12BE
FUNCTIONS
AH-A07BE/A09BE/A12BE are noty provided with
the heating function
1. Temperature control characteristic
1-1
COOL operation
In the “COOL” mode, the thermostat circuit is
controlled by four thermostat lines (C1 thru C4).
1-3
HEAT operation
In the “HEAT” mode, the thermostat circuit
is controlled by six thermostat lines (H01 thru
H4).
Figure Y-1
1-2
DRY operation
In the “DRY” mode, the thermostat circuit is
controlled by three thermostat lines (D1 thru
D3).
Figure Y-3
2. Operation modes
2-1
COOL operation
The compressor turns on or off, at the
thermostat lines C3 and C4. The outdoor fan
motor is also controlled with the compressor.
Figure Y-4
Figure Y-2
Room temperature
Preset temperature
Room 
temperature
transition
C3
C4
States 1 & 3 : Compressor ON
State 2 : Compressor OFF
1
2
3
18
32
C1
C2
C3
C4
17.5
18.5
19.5
20.5
31.5
32.5
33.5
34.5
Preset temperature (˚C)
Room temperature (˚C)
Room temperature(˚C)
Preset temperature (˚C)
18
32
D1
D2
D3
17.5
18.5
19.5
31.5
32.5
33.5
Preset temperature (˚C)
H4
H3
H2
H1
H02
H01
17
19
21
22
24
26
31.5
32.5
34.0
35.0
36.0
37.0
18
32
Room temperature(˚C)
AH-A07BE/09BE/12BE
AY-A07BE/09BE/12BE
AU-A07BE/09BE/12BE
AE-A07BE/09BE/12BE
15
Figure Y-5
2-2
DRY operation
On the switch on, the compressor always starts
to operate for 2 minutes with fan speed “DL” .
The microcomputer reads the room temperature
2 minutes after this first compressor operation.
This room temperature is set as the preset
temperature automatically.
The preset temperature ranges from 18˚C to
32˚C. When the room temperature is below
18˚C, the preset temperature is  set to 18˚C,
and when the room temperature is over 32˚C,
the preset temperature is set to 32˚C.
Dry operation is divided into three zones
(Cooling zone, Dehumidifying zone and
Circulating zone) by thermostat lines (D1 to
D3), and the compressor and the fan motor
are controlled in each zone as shown in Table
Y-1.
Room temperature
Preset temperature
Room 
temperature
transition
D3
D2
D1
States 1 & 5 : Cooling zone
States 2 & 4 : Dehumidifying zone
States 3 : Circulating zone
3
4
5
1
2
Room temperature
Preset temperature
Room
temperature
transition
States 1 & 3 : Compressor ON
States 2  : Compressor OFF/(ON)
                  (Hot-keep function)
H1
H2
3
1
2
Compressor
Cooling zone
Dehumidifying zone
Circulating zone
Fan speed
ON
"DH"
"DL"
"DL" or OFF
ON
OFF
Table Y-1
2-3
Heat operation
The compressor turns on or off, at State  2  ,
turns on continuously at State  1  &  3 .
Figure Y-6
3. Fan speed
Fan speeds are given by the indoor fan motor, "DL"~"HH" which are available in the following operation mode.
Table Y-2
Fan switch
DL
Fan speed
Fan switch (AUTO)
07BE TYPE
AY
AH
AY
AH
AY
AH
(r.p.m.)
630
630
690
690
750
750
710
710
740
740
840
840
710
710
760
760
840
840
750
750
790
790
860
860
830
830
910
910
930
930
900
900
990
990
970
970
950
950
1090
1090
1010
1010
700
750
850
830
920
920
850
950
950
900
1000
1000
950
1050
1040
990
1100
1080
09BE TYPE
12BE TYPE
DH
DRY
COOL
CL
COOL SOFT
CAL
CM
COOL LOW
CAH
CH
COOL HIGH
HUL
HL
HEAT SOFT
HEAT
HAL
HM
HEAT LOW
HAH
HH
HEAT HIGH
16
AH-A07BE/09BE/12BE
AY-A07BE/09BE/12BE
AU-A07BE/09BE/12BE
AE-A07BE/09BE/12BE
OFF
OFF
ON
ON
U1
U2
U1
U2
U2'
U2'
Within 3 minutes
Over 3 minutes
Figure Y-8
Figure Y-7
5. Preheat air flow
This function is intended to prevent cold air from being
discharged when the heating operation starts or when
defrosting.
When the indoor pipe temperature is below 29˚C at the
begining of the heat operation or after defrosting, the
indoor fan motor stays.
When the indoor pipe temperature gets higher than
29˚C, the fan motor is turned on at speed “HUL” after
compensation of starting.
When the indoor pipe temperature exceeds 35˚C, the
specified fan speed is restored. When the indoor pipe
temperature falls below 30˚C, the fan speed shifts
down to “HUL”. And, when the indoor pipe temperature
falls below 23˚C, the fan motor turns off. Then, over
29˚C , it turns on again at speed “HUL”.
4. Hot-Keep
This function automatically controls the on-off operation
of the indoor fan motor in accordance during the
heating operation, thereby preventing the air conditioner
from delivering a cold air when the compressor is off.
When the room temperature exceeds the thermostat
line “H1”, the compressor is turned off, and the indoor
fan motor is turned off after rotating at “HUL” for 30
seconds. 3 minutes and 10 seconds after turning off the
compressor, the indoor fan motor is turned on for 3
minutes and 20 seconds. At 10 seconds after turning
on the compressor, the indoor fan motor is turned  on.
The next compressor OFF time is for 3, 8 or more than
8 minutes according to the room temperature (the time
increases with a rise of room temperature) when 3
minutes elapse after turning on the compessor.
6. Overheating protection system
When overloading occurs during the heating operation,
this system controls the outdoor fan motor according to
the indoor pipe temperature to prevent the overloading
of the compressor and restrain the rise in high pressure.
When the indoor pipe temperature exceeds U1˚C, the
outdoor fan motor is turned off, and when the indoor
pipe temperature falls U2˚C, the outdoor fan motor
turns on.
If 3 minutes elapse after turning off outdoor fan motor,
the outdoor fan motor is turned on, when the indoor
pipe falls U2' ˚C,
Pipe temperature(˚C) 
24
29
30
35
OFF
UL
UL
UL
OFF
Preset
Fan speed
HH
HAH
HM
HAL
HL
HUL
53˚C
53˚C
52˚C
52˚C
U1
AY-A07BE
AY-A09BE
AY-A12BE
U2'
49˚C
53˚C
52˚C
49˚C
53˚C
52˚C
49˚C
49˚C
U2
54˚C
U2
53˚C
U'2
50˚C
U2
54˚C
U2
53˚C
U2'
50˚C
U2
Fan speed
LIne
MODELS
Figure Y-9
Table Y-3
Compressor
ON
OFF
Indoor
fan motor
30sec.
time
UL
ON
OFF
3 min.
3 min.
10sec.
UL
30sec.
10sec.
Thermo off
Page of 48