AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
29
(2) Defrosting conditions
The temperature of the outdoor heat exchanger and
the temperature of the outdoor are detected by 2
sensors, and if it stays in the preset defrost zone for
approximately 120 seconds, defrosting start is
enabled.
If defrosting is enabled when the defrost mask time
ends, defrosting is performed. If defrosting is not
enabled, the machine waits until defrosting is enabled.
Defrost mask times is 20 minutes.
The defrosting zone is decided by outdoor
temperature and outdoor heat exchanger
temperature.
(3) During defrosting
When defrosting begins, the compressor stops.
Approximately 1 minutes later, the compressor
reactivates in the refrigeration cycle, and the outdoor
heat exchanger is defrosted.
Each mode is as follows:
The outdoor fan is stopped
The operating frequency is 90Hz/76Hz [AY-X138E/
AY-X108E]
The indoor fan is stopped
(4) Defrost stop
When defrosting time exceeds 12 minutes
When the temperature of the outdoor heat exchanger
rises above approximately 10˚C
Defrost stop is determined by either of the above
conditions, and the compressor is stopped.
At the same time, the outdoor fan go ON. The
compressor is reactivated in the heating cycle 1
minutes after it was stopped, and normal control
resumes.
2-2 Frequency control
(1) AC current peak control
This control lowers the compressor frequency if the
AC current exceeds the set values. If the current is
below the set values, the compressor frequency will
not be raised above that frequency, as the maximum
frequency, for 1 minute.
Model
Set value
AE-X108E
During heating   Approximately 8.00 A
AE-X138E
During heating   Approximately 10.14 A
AE-X108E, AU-X108E
During cooling   Approximately 6.15A
AE-X138E, AU-X138E
During cooling   Approximately 7.50 A
(2) Control for prevention of indoor heat exchanger
overheating
If the temperature of the indoor heat exchanger
exceeds the overheating prevention line during
heating due to the operating frequency or the nature
of the operation, the frequency is lowered by
approximately 5 to 10 Hz. After that, the frequency is
lowered by approximately 5 to 10 Hz once every 60
seconds. When the temperature of the indoor heat
exchanger goes below the overheating prevention
line, the frequency is raised by approximately 5 Hz
once every 60 seconds, and normal operation is
restored.
If the frequency is lowered to minimum frequency
without the temperature of the indoor heat exchanger
decreasing and this condition lasts for 1 minute, the
compressor will be stopped.
Overheating prevention line
Operating frequency
Above
50 to
43 to
Below
50 Hz
43 Hz
37 Hz
37 Hz
During normal operation
54
53
52
51
During full power operation
58
57
56
54
(3) Control for prevention of outdoor heat exchanger
overheating
If the temperature of the outdoor heat exchanger
exceeds approximately 60
°
C during cooling, the
operating frequency is lowered by approximately 5 to
20 Hz. After that, the frequency is lowered by
approximately 5 to 10 Hz once every 120 seconds.
When the temperature of the outdoor heat exchanger
goes below approximately 57˚C, the frequency is
raised by approximately 5 Hz once every 60 seconds,
and normal operation is restored.
If the frequency is lowered to minimum frequency
without the temperature of the outdoor heat exchanger
decreasing and this condition lasts for 1 minute, the
compressor will be stopped.
(4) Control for prevention of discharge overheating
If the discharge temperature exceeds approximately
105
°
C during compressor operation, the operating
frequency is lowered by approximately 5 Hz. After
that, the frequency is lowered by approximately 5 Hz
once every 60 seconds. When the temperature of the
outdoor heat exchanger goes below approximately
104˚C, the frequency is raised by approximately 5 Hz
once every 60 seconds, and normal operation is
restored.
If the frequency is lowered to minimum frequency
without the discharge temperature decreasing and this
condition lasts for 1 minute, the compressor will be
stopped.
(5) Control for prevention of indoor heat exchanger
freezing
If the temperature of the indoor heat exchanger goes
below approximately 5
°
C during cooling, the operating
frequency is lowered by approximately 5 Hz. After
that, the frequency is lowered by approximately 5 Hz
once every 60 seconds. When the temperature of the
indoor heat exchanger rises above approximately 5
°
C,
the frequency is raised by approximately 5 Hz once
every 60 seconds, and normal operation is restored.
If the temperature of the indoor heat exchanger goes
down to approximately 0
°
C and this condition
continues for 4 minutes, the compressor is stopped.
When the temperature rises above approximately 2˚C,
normal operation is restored.
2-3 Overcurrent protection
(1) Compressor lock detection
If the set value (4.37 A: AE-X138E, AU-X138E / 3.83
A: AE-X108E, AU-X108E) of AC current is exceeded
at 10 to 30 Hz when operation begins, operation is
stopped. In this case, the compressor and outdoor fan
does not stop, and 170 seconds after operation is
stopped, another try will be made. Three retries are
allowed. On the fourth retry, a complete stop request
signal is sent to the indoor unit, and the outdoor unit
will remain stopped until reset is performed. At this
time, the 3-minute delay for control of the outdoor unit
will not function; therefore, do not cancel by removing
the plug and cutting the power.
AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
30
(2) DC overcurrent detection, AC overcurrent detection
To protect against overcurrent due to sudden
changes in load, the compressor is stopped if the set
value (29 A: AE-X138E, AU-X138E / 24 A: AE-
X108E, AU-X108E) DC is exceeded in the DC
section, or the set value (15 A: AE-X138E, AU-
X138E / 11 A: AE-X108E, AU-X108E)AC is
exceeded in the AC section. In this case, the outdoor
fan does not stop, and 170 seconds after operation is
stopped, another try will be made. Three retries are
allowed. On the fourth retry, a complete stop request
signal is sent to the indoor unit, and the outdoor unit
will remain stopped until reset is performed. At this
time, the 3-minute delay for control of the outdoor unit
will not function; therefore, do not cancel by removing
the plug and cutting the power.
2-4 Compressor protector control
If the temperature of the compressor chamber
exceeds 114
°
C, the compressor is stopped. In this
case, the outdoor fan does not stop, and when the
compressor chamber temperature decreases to
100
°
C three minutes after operation is stopped,
another try will be made. Three retries are allowed.
On the fourth retry, a complete stop request signal is
sent to the indoor unit, and the outdoor unit will
remain stopped until reset is performed. At this time,
the 3-minute delay for control of the outdoor unit will
not function; therefore, do not cancel by removing the
plug and cutting the power.
2-5 Power transistor module protector
If the temperature of the chips in the power transistor
module exceeds 110 
°
C, the compressor is stopped.
In this case, the outdoor fan does not stop, and when
the temperature of the chips in the power transistor
module decreases to 110 
°
C  170 seconds after
operation is stopped, another try will be made. Three
retries are allowed. On the fourth retry, a complete
stop request signal is sent to the indoor unit, and the
outdoor unit will remain stopped until reset is
performed. At this time, the 3-minute delay for control
of the outdoor unit will not function; therefore, do not
cancel by removing the plug and cutting the power.
2-6 Serial signals
(1) Serial signals consist of all 96-bit signals.
(2) If the outdoor unit does not receive a serial signal, it
will stop approximately 30 seconds later. Note that this
is true only of normal operation; in test mode, it does
not stop and operation takes place based on the test
mode commands.
Function
NO
Description
Detection 
time
Restart 
condition
Restart 
times
Indoor Outdoor
Operation
Self diagnostic
display
  
Indoor 
fan lock
Indoor fan 
rpm error
Indoor 
freezing 
guard
Indoor 
overheating 
control
DC 
overcurrent
or overheat 
of the IPM
1
2
3
4
Stops operation if no revolution pulse 
signal is input from the indoor fan motor 
for one minute.
Stops operation if the revolution pulse 
signal from the indoor fan indicates low 
rpm (approximately 300 rpm or less).
Lowers the operating frequency if the 
temperature of the indoor heat exchanger 
goes below 5
°
C during cooling. Stops the 
compressor if the temperature stays 
below 0
°
C for 4 minutes.
Stops the compressor if a current of 
approximately 29A/24A 
[AY-X138E/AY-X108E] or more flows in the 
power transistor module. Also stops the 
compressor if the temperature of the power 
transistor module is exceeds 110
°
C.
Lowers the operating frequency if the 
temperature of the indoor heat exchanger 
rises above the overheating temperature 
during heating. Stops the compressor if the 
temperature stays above the overheating 
temperature for 1 minute at minimum 
frequency.
Set values for overheating temperature
During normal operation: 51
°
C to 54
°
C
During full power operation: 54
°
C to 
58
°
C
Operation OFF
When indoor 
fan is revolving
During cooling 
and dry 
During heating
During 
compressor 
operation
Automatically restarts when 
the exchange temperature 
rises above the freezing 
prevention temperature 
(above 2
°
C)
Automatically restarts when 
the exchange temperature 
goes below the overheating 
temperature.
Automatically restarts after 
safety time (170 seconds) 
No limit
Yes
No
No limit
No
No
No limit
No
No
4 times
Yes
Yes
FUNCTION AND OPERATION OF PROTECTIVE PROCEDURES
AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
31
Function
NO
Description
Detection 
time
Restart 
condition
Restart 
times
Indoor Outdoor
Operation
Self diagnostic
display
  
AC 
overcurrent
Compressor
lock
Compressor 
overheating 
control
5
6
7
Lowers the operating frequency if the 
temperature of the compressor chamber 
thermistor (TH1) rises above 105
°
C.
Stops the compressor if the thermistor 
stays above 104
°
C for 4 minutes, or 1 
minute at minimum frequency or less.
Lowers the operating frequency if the 
compressor AC current exceeds 
Peak control level 
[10.1/8.0A (heating), 7.5/6.15A (cooling)] 
[AY-X138E/AY-X108E] 
Stops the compressor if the current 
exceeds peak control level at 40 Hz or less.
Stops the compressor if the compressor 
AC current exceeds 15A.
During 
compressor 
operation
Immediately 
after 
compressor 
activation.
During 
compressor 
operation
During 
compressor 
operation
Automatically restarts after 
safety time (170 seconds)
Automatically restarts after 
safety time (170 seconds) 
Automatically restarts after 
safety time (170 seconds)
No limit
No
No
No limit
Yes
No limit
 
Yes
No limit
No
No
Compressor
high
temperature 
error
8
Stops the compressor if the compressor 
chamber thermistor is above 114
°
C.
(Or when TH1 shorts)
During 
operation
Outdoor 
overheating 
control
9
Automatically restarts after 
safety time ( (170 seconds)
When 
compressor 
is activated
Outdoor 
thermistor 
short
10
Stops the compressor if an outdoor 
thermistor (excluding TH1) shorts.
(Except for the AU-X138E, AU-X108E)
Automatically restarts after 
safety time ( (170 seconds)
4 times
Yes
Yes
4 times
Yes
Yes
4 times
Yes
Yes
4 times
Yes
Yes
When 
compressor 
is activated
Outdoor 
thermistor 
short
11
Stops the compressor if the circuit of an 
outdoor thermistor breaks.
(Except for the AU-X138E, AU-X108E)
Automatically restarts after 
safety time ( (170 seconds)
4 times
Yes
Yes
4 times
Yes
Yes
During 
compressor 
operation
AC 
abnormal 
current error
12
Stops the compressor if if the operating 
frequency is above 70 Hz and the 
compressor current is below 1.1 A/0.85 A.
[AE-X138E/AE-X108E]
Automatically restarts after 
safety time ( (170 seconds)
4 times
Yes
Yes
During 
operation
Serial 
signal error
Four-way 
valve error
13
14
Restarts after reception of 
serial signal.
Automatically restarts after 
safety time (170sec.) 
During 
operation
4 minutes after
compressor 
activation
Stops the compressor if the outdoor unit 
does not receive a serial signal from the 
indoor unit for 30 seconds.
When the rise and fall in the detected 
temperature of the outdoor heat 
exchanger thermistor (TH2) do not agree 
with the operating cycle.
Turns the compressor relay off if the 
indoor unit does not receive a serial 
signal from the outdoor unit for 8 minutes.
Stops the compressor if the compressor 
AC current exceeds 3.37/2.83A
[AY-X138E/AY-X108E] 
immediately after activating the compressor 
(at 17 to 30 Hz).
Lowers the operating frequency if the 
temperature of the outdoor heat exchanger 
rises above 57
°
C during cooling. Stops the 
compressor if the temperature stays above 
57
°
C for 4 minutes, or 1 minute at 
minimum frequency or less.
Automatically restarts less 
than 8 minutes after operation 
stops.
Automatically restarts 
when thermistor (TH1) 
temperature falls below 
100
°
C (approximately 30 
minutes)
AH/AU-X108E
AY/AE-X108E
AH/AU-X138E
AY/AE-X138E
32
: Blinks at 2-second intervals
: OFF
: ON
: Blinks 3 times at 0.2-second intervals
Indoor and outdoor unit 
completely stopped
Indoor unit 
operating
Outdoor unit 
completely stopped
Display by indoor unit operation lamp
Displayed in a pattern which comes on at  the same 
time as the timer lamp
4 seconds off
What to check, procedure
Display by 
outdoor 
unit lamp 
LED 1
Diagnosis
Solution
Condition 
of indoor 
and 
outdoor 
unit
Normal
Once
Twice
3 times
4 times
5 times
6 times
7 times
Compressor lock error
DC overcurrent error
AC overcurrent error
Normal
Serial short
Serial open
Does compressor active ? Does it go off immediately after active ?
1. Check the circuit in the power transistor module.
2. Is the outdoor fan revolving ?
1. Is the discharge outlet of the outdoor unit clogged ?
1. Check the wiring between units.
1. Check the wiring between units.
1. Check the wiring between units.
2. Check the fuse in the outdoor unit.
3. Indoor control board.
4. Outdoor control board.
1. Measure the resistance of thermistor TH2 on the outdoor unit
    (see Figure 2).
1. Replace power transistor 
module
1. Clear the discharge outlet.
8 times
4-way valve abnormal
(AE-X138E and 
AE-X108E only)
1. Measure the resistance of indoor heat exchanger thermistor TH2.
2. Is the switching transistor of 4 way valve functioning normally ?
3. Is the 4 way valve functioning normally ?
1. Rewire.
1. Rewire.
Indoor fan out of order
1. Is the fan motor locked ?
2. Is the wiring connector firmly fitted ?
3. Is the speed signal applied to the motor ?
Overheat of the comp-
ressor error
(protector operating) or 
outdoor compressor  
thermistor TH1 short
Outdoor power supply  
does't turn on.
Wiring mistake.
1. Rewire.
2.
Replace the fuse, replace the 
outdoor board assembly.
3. Replace the board.
4. Replace the board.
1. Replace fan motor
2. Reattach.
3.
Replace the indoor control board 
assembly.
1.
Replace indoor heat exchanger 
thermistor.
2.
Replace outdoor units control board.
3.
Replace the 4 way valve.
1.
Replace the outdoor control board 
assembly 
(Current transformer wire break.) 
1. Reattach.
2.
Replace the outdoor thermistor 
assembly.
1.
Replace the outdoor thermistor 
assembly.
1.
Clear the discharge outlet.
2.
Assure power supply voltage.
3.
Refill to rated amount.
4.
Replace the outdoor ther-mistor 
assembly.
5.
Replace the indoor control 
board 
assembly or only TH2
.
1. Apply an external shock to the 
compressor.
2. Replace the compressor.
1. Can voltage be detected at the current transformer on the outdoor 
unit control board?
1. Are the connectors of the outdoor unit thermistors well attached ?
2. Measure the resistance of thermistors TH1 and TH2 on the 
outdoor unit (see Figure 2).
1. Is the discharge outlet of the outdoor unit clogged ?
2. Is the power supply voltage at least 198 V at full power operation ?
3. Check for refrigerant leaks at the tubing connections.
4. Measure the resistance of compressor thermistor TH1 on the 
outdoor unit (see Figure 2).
5. Measure the resistance of heat exchanger pipe thermistor TH2 on 
the indoor unit (see Figure 1).
AC abnormal current  
error
Open circuit of the 
thermistor error
Short circuit of the  
thermistor error
BREAK 
DOWN 
DIAGNOSIS 
PROCEDURE
Self-diagnostic 
procedure 
using 
display 
mode
If 
the 
timer 
lamp 
blinks 
during 
operation, 
the 
problem 
can 
be 
diagnosed 
using
the 
following 
table.
N
o
te
:
1
.
N
o
rm
a
O
n
ly
 t
h
e
 t
im
e
la
m
p
 b
lin
k
s
E
rr
o
D
is
p
la
y
e
d
 b
y
 b
lin
k
in
g
 o
ru
n
 l
a
m
p
 (
a
b
o
v
e
 t
a
b
le
).
2
.
If th
e power
 plug is r
e
m
o
v
e
d
 f
ro
m
 t
h
e
 o
u
tl
et
 o
r t
he br
eak
e
r i
sw
itc
he
d t
o "O
F
F
", the
 s
elf-
dia
gn
os
ti
me
mory will 
be erased
.
3
.
E
x
a
m
p
le
 o
o
u
td
o
o
u
n
it
 L
E
D
 1
 b
lin
k
in
g
 :
Page of 56
Display

Click on the first or last page to see other AH-X108 service manuals if exist.