Sharp AH-A129 Service Manual ▷ View online
AH-A129E
AU-A129E
AU-A129E
17
7. Take the thermistor holder from evaporator.
8. Take out the thermistor from evaporator.
9. Disconnect fan motor connectors and others.
10.Loose 2 screws for a pipe cover and take it out.
Loose the earth screw.
11.Loose 6 screws fixing control box and take out control
ass’y.
12.Loose 2 screws fixing drain pan ass’y. (Left side)
13.Loose a screw fixing drain hose.
14.When assembling, make sure that O ring is fitted to
the drain hose.
O-ring
O-ring
Drain hose
(Section)
AH-A129E
AU-A129E
AU-A129E
18
15.Take out the drain pan ass’y.
16.Loose a screw fixing cross flow fan to motor.
17.Slide the cross fan leftward to depart from the motor
shaft and take out fan motor.
19.Take out the fan bearing ass’y.
18.Loose 2 screws fixing evaporator.
20.Take out the cross flow fan while slightly lifting the
evaporator.
AH-A129E
AU-A129E
AU-A129E
19
1
Remove the three(3) screws holding the right
side cover and take it out.
side cover and take it out.
2
Remove the three(3) screws holding the left side
cover and take it out.
cover and take it out.
FOR OUTDOOR UNITMODEL AU-A129E
CAUTION:DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING
3
Remove the another screws holding the cabinet
and take it out.
and take it out.
NOTE: Number as shown in following figure is the re
moval order.
Figure D-1. OUTDOOR UNIT
Left side cover
Condenser
Right side cover
Cabinet
Fan motor
Propeller fan
Compressor
Fan guard
1
2
Bulkhead
3
AH-A129E
AU-A129E
AU-A129E
20
TROUBLESHOOTING OF A CONTROL CIRCUIT
measure the secondary voltage
of transformer.
of transformer.
YES
NO
YES
NO
The machine does not function
at all with remote controller and
switches on the indoor unit.
at all with remote controller and
switches on the indoor unit.
Using a meter, measure the
voltage between anodes of D1
and D2 on the PWB ass'y 1.
voltage between anodes of D1
and D2 on the PWB ass'y 1.
Is the measured value
approx. 20.6 Vac ?
Replace the PWB with a new
one.
one.
Is the 2.5A fuse
open circuit ?
Replace the fuse and varistor
with new ones.
with new ones.
Replace the transformer with
a new one.
a new one.
Click on the first or last page to see other AH-A129 service manuals if exist.