Sharp AE-A129E (serv.man2) Service Manual / Technical Bulletin ▷ View online
AIR2002 10 02
Month of Issue:
October 2002
Classification:
White
AIR CONDITIONER TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference EHH-159
Revision 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
Red
Carry out on all units
MODELS
AEA129E
REASON
Due to a change in supplier the fan motor has been changed. As a result, the motor
stay sub angle has also been changed.
stay sub angle has also been changed.
ACTION
When replacing the fan motor it is also necessary to replace the motor stay sub angle.
REF NO
DESCRIPTION
NEW PART NUMBER
PRICE CODE
1-1
Motor stay sub angle
LSUB-A010JBP0
AG
1-2
Fan motor
CMOTLA870JBE0
BR
Display