Panasonic TX-L47DT60Y / TX-LR47DT60 Service Manual ▷ View online
Model No. : TX-L47DT60Y+LR
Parts List
Change Safety
Ref.
No.
Part No.
Part Name & Description
Q'ty
Remarks
SK331
THEJ036J
SCREW
1 PAVCCZ
SK332
THEJ036J
SCREW
1 PAVCCZ
SK333
THEJ056J
SCREW
1 PAVCCZ
SK334
THEJ056J
SCREW
1 PAVCCZ
SK335
THEJ056J
SCREW
1 PAVCCZ
SK336
THEJ036J
SCREW
1 PAVCCZ
SK337
THEJ036J
SCREW
1 PAVCCZ
SK338
THEJ036J
SCREW
1 PAVCCZ
SP01
XYN3+C6FJ
SCREW
1 PAVCCZ
SP02
XYN3+C8FJ
SCREW
1 PAVCCZ
SP03
XYN3+C6FJ
SCREW
1 PAVCCZ
SP04
XYN3+C6FJ
SCREW
1 PAVCCZ
SP05
XYN3+C6FJ
SCREW
1 PAVCCZ
SP06
XYN3+C6FJ
SCREW
1 PAVCCZ
TOPCUS
TPD0E12761
CUSHION TOP
1 PAVCCZ
61
Schematic Diagrams Note
NOTE
1. RESISTOR
All resistors are carbon ¼W resistor, unless marked otherwise.
Unit of resistance is OHM (
Unit of resistance is OHM (
) (k=1,000, M=1,000,000)
2. CAPACITORS
All capacitors are ceramic 50V unless marked otherwise.
Unit of capacitance is
Unit of capacitance is
F unless otherwise stated.
3. COIL
Unit of inductance is
H, unless otherwise stated.
4. TEST
POINT
Test Point Position
5. EARTH
SYMBOL
Chassis Earth (Cold)
Line Earth (Hot)
6. VOLTAGE
MEASUREMENT
Voltage is measured by a D.C. voltmeter.
Measurement conditions are as follows:
Power source 220V-240V AC, 50/60 Hz
Receiving Signal Colour Bar signal (RF)
All customer controls Maximum position
Measurement conditions are as follows:
Power source 220V-240V AC, 50/60 Hz
Receiving Signal Colour Bar signal (RF)
All customer controls Maximum position
7.
Indicates the Video signal path
Indicates the Audio signal path
These schematic diagrams are the latest at time of printing and are subject to change without notice.
REMARKS
a. Do not touch the hot part, or the hot and cold parts at the same time, as you are liable to a shock hazard.
b. Do not short circuit the hot and cold circuits as electrical components may be damaged.
c. Do not connect an instrument, such as an oscilloscope, to the hot and cold circuits simultaneously as this may cause
c. Do not connect an instrument, such as an oscilloscope, to the hot and cold circuits simultaneously as this may cause
fuse failure. Connect the earth of the instruments to the earth connection of the circuit being measured.
d. Make sure to disconnect the power plug before removing the chassis.
NOTE
1. The Power Supply Circuit contains a circuit area, which uses a separate power supply to isolate the earth connection.
The circuit is defined by HOT and COLD indications in the schematic diagram. All circuits, except the Power Circuit, are
COLD.
The circuit is defined by HOT and COLD indications in the schematic diagram. All circuits, except the Power Circuit, are
COLD.
IMPORTANT SAFETY NOTICE
Components identified by mark have special characteristics
important for safety. When replacing any of these components, use
only manufacturers' specified parts.
important for safety. When replacing any of these components, use
only manufacturers' specified parts.
62
63
64
Click on the first or last page to see other TX-L47DT60Y / TX-LR47DT60 service manuals if exist.