DOWNLOAD Panasonic TX-L32X3E / TX-LR32X3 Service Manual ↓ Size: 15.54 MB | Pages: 64 in PDF or view online for FREE

Model
TX-L32X3E TX-LR32X3
Pages
64
Size
15.54 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / GLP26 CHASSIS
File
tx-l32x3e-tx-lr32x3.pdf
Date

Panasonic TX-L32X3E / TX-LR32X3 Service Manual ▷ View online

Description
Cct Ref
Parts Number
Description
Cct Ref
Parts Number
7P CONNECTOR     
A10
K1KY07AA0719
A10-KA10 WIRE    
A10-KA10 TXJA10PAUB-2
4P CONNECTOR    
A12
K1KA04BA0055
A12-SPK WIRE     
A12-SPK TXJA12PAUB-1
60P CONNECTOR    
A15
K1MY60B00005
LVDS WIRE        
A15-PAN TSX0E207
14P CONNECTOR    
CN0102
K1KA14A00248
OPTICAL LINK     
D3050
K7AAAY000011
YUV_AUDIO IN_V IN
JK1001B
K1U608A00002
SCART TERMINAL   
JK1003
K1FY121A0012
HDMI TERMINAL    
JK1020
K1FY119D0015
HDMI TERMINAL    
JK1021
K1FY119D0015
HP TERMINAL      
JK1052
K2HC1YYB0063
CI SLOT          
JK1070
K1NA68B00056
SD SLOT          
JK8850
K1NA12E00016
7P CONNECTOR     
KA10
K1KA07B00135
12P CONNECTOR    
LD2
K1KY12BA0322
14P CONNECTOR    
LD4
K1KY14BA0302
2P CONNECTOR     
P1
K1KA02B00295
16P CONNECTOR    
P2
K1KY16BA0311
14P CONNECTOR    
P4
K1KA14BA0311
P4-LD4 WIRE      
P4-LD4
TXJLEDPAUB-2
SWITCHES
SWITCH           
SW7401
K0F122A00203
SWITCH           
SW7402
EVQ11G05R
SWITCH           
SW7403
EVQ11G05R
SWITCH           
SW7404
EVQ11G05R
SWITCH           
SW7406
EVQ11G05R
SWITCH           
SW7407
EVQ11G05R
DIFFERENCES FOR MODEL  TX--L32X3E
EXPLODED VIEW
A P.C.B.         
    23
A-L32X3E
BATTERY COVER OF RC
    24
BAT-C-0487
MODEL LABEL      
    25
TBM0E2695
REMOTE CONTROL   
    26
N2QAYB000487
INSTRUCTION BOOKS
GERMAN           
.
TQB0E2171A
DUTCH            
.
TQB0E2171B
ITALIAN          
.
TQB0E2171C
FRENCH           
.
TQB0E2171D
SPANISH          
.
TQB0E2171E
SWEDISH          
.
TQB0E2171F
NORWEGIAN        
.
TQB0E2171G
FINNISH          
.
TQB0E2171H
LITHUANIAN       
.
TQB0E2171I
PORTUGUESE       
.
TQB0E2171J
DANISH           
.
TQB0E2171K
BULGARIAN        
.
TQB0E2171M
ROMANIAN         
.
TQB0E2171N
LATVIAN          
.
TQB0E2171O
POLISH           
.
TQB0E2171P
HUNGARIAN        
.
TQB0E2171Q
CZECH            
.
TQB0E2171R
GREEK            
.
TQB0E2171S
TURKISH          
.
TQB0E2171T
ENGLISH          
.
TQB0E2171U
CROATIAN         
.
TQB0E2171V
SLOVAKIAN        
.
TQB0E2171W
CD               
.
TQB0E2171X
ESTONIAN         
.
TQB0E2171Z
I.C.s
EEPROM STM       
IC8901
STML32X3E
EEPROM SLD2      
IC8902
X24CL32X3E
RESISTORS
SMD
JS0003
D0GAR00J0005
.063W
5%
0 Ω
DIFFERENCES FOR MODEL  TX--LR32X3
EXPLODED VIEW
A P.C.B.         
    23
A-LR32X3
BATTERY COVER OF RC
    24
BAT-C-0666
MODEL LABEL      
    25
TBM0E2697
REMOTE CONTROL   
    26
N2QAYB000666
INSTRUCTION BOOKS
KAZAKHSTAN       
.
TQB0E21729
RUSSIAN          
.
TQB0E2172L
UKRAINIAN        
.
TQB0E2172Y
I.C.s
EEPROM STM       
IC8901
STMLR32X3
EEPROM SLD2      
IC8902
X24CLR32X3
RESISTORS
SMD
JS0012
D0GAR00J0005
.063W
5%
0 Ω
RTL
RTL
X
X
37
Schematic Diagrams  
 
 
 
 
 
 
 
NOTE 
 
1. RESISTOR 
All resistors are carbon ¼W resistor, unless marked otherwise. 
Unit of resistance is OHM (
) (k=1,000, M=1,000,000) 
2. CAPACITORS 
All capacitors are ceramic 50V unless marked otherwise. 
Unit of capacitance is 
F unless otherwise stated. 
3. COIL 
Unit of inductance is 
H, unless otherwise stated. 
 
4. TEST 
POINT 
                                        Test Point Position 
 
 
 
5. EARTH 
SYMBOL 
 
                                        Chassis Earth (Cold) 
 
                                        Line Earth (Hot) 
 
 
6. VOLTAGE 
MEASUREMENT 
Voltage is measured by a D.C. voltmeter. 
Measurement conditions are as follows: 
Power source                     220V-240V AC, 50 Hz 
Receiving Signal                 Colour Bar signal (RF) 
All customer controls Maximum position 
 
7.  
 
                                        Indicates the Video signal path 
 
                                        Indicates the Audio signal path 
 
 
These schematic diagrams are the latest at time of printing  and are subject to change without notice. 
 
REMARKS 
 
a.  Do not touch the hot part, or the hot and cold parts at the same time, as you are liable to a shock hazard. 
b.  Do not short circuit the hot and cold circuits as electrical components may be damaged. 
c.  Do not connect an instrument, such as an oscilloscope, to the hot and cold circuits simultaneously as this may cause 
fuse failure. Connect the earth of the instruments to the earth connection of the circuit being measured. 
d.  Make sure to disconnect the power plug before removing the chassis. 
 
NOTE 
 
1. The Power Supply Circuit contains a circuit area, which uses a separate power supply to isolate the earth connection. 
 The circuit is defined by HOT and COLD indications in the schematic diagram. All circuits, except the Power Circuit, are 
 COLD. 
 
 
IMPORTANT SAFETY NOTICE 
Components identified by     mark have special characteristics 
important for safety. When replacing any of these components, use 
only manufacturers' specified parts. 
38
39
40
Page of 64
Display