DOWNLOAD Panasonic TX-29F250T Service Manual ↓ Size: 4.82 MB | Pages: 45 in PDF or view online for FREE

Model
TX-29F250T
Pages
45
Size
4.82 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / GP2 CHASSIS
File
tx-29f250t.pdf
Date

Panasonic TX-29F250T Service Manual ▷ View online

Power Source
AC AUTO 110-240V, 50/60 Hz
Power Consumption
164 W
Standby condition : 7 W
Aerial Terminal
Impedance : 75
, Coaxial type
Tuning System
Frequency Synthesizer
Auto Search Tuning
Pos : 100 Positions
Receiving System
21 Systems
Receiving Channels
Regular TV
0-12 (PAL/SECAM B, K1)
0-12 (PAL B AUST.)
1-9 (PAL B N.Z.)
1-12 (PAL/SECAM D)
1-12 (NTSC M JAPAN)
2-13 (NTSC M U.S.A)
21-69 (PAL G, H, I/SECAM G, K, K1)
28-69 (PAL B AUST.)
13-57 (PAL D, K)
13-62 (NTSC M JAPAN)
14-69 (NTSC M U.S.A.)
CATV
S1-S20 (OSCAR)
1-125 (U.S.A. CATV)
C13-C49 (JAPAN)
S21-S41 (HYPER)
Z1-Z37 (CHINA)
5A, 9A (AUST.)
Intermediate Frequency
38.0 MHz
Video
31.5 MHz (D, K) / 32.5 MHz (B, G)
32.0 MHz (I) / 32.5 MHz (M)
Sound
33.57 MHz (PAL) /
TX-29F250T
GP2 Chassis
Colour
33.6 MHz (SECAM)
34.42 MHz (NTSC) /
33.75 MHz (SECAM)
Video/Audio/Terminals
AV 1, 2, 3, 4
S-Video In
Y:1 Vp-p, 75
C:0.3 Vp-p, 75
DVD
Y
1.0Vp-p, 75
P
B
0.7Vp-p, 75
P
R
0.7Vp-p, 75
Video In
1Vp-p, 75
Audio In
Approx. 0.5V, 47K
Monitor Out
Video In
1Vp-p, 75
Audio In
Approx. 0.5V, 47K
High Voltage
31.0 ± 1.0 at zero
beam current
Picture Tube
A68LZU185X Type 29 (68 cm)
Measured diagony
104° deflection
Audio Output
20 W speaker
Dimensions (W x D x H)
786 mm x 508 mm x 578 mm
Weight (Mass)
43 kg (Net)
Note:
Specifications are subject to change without notice. Mass and
dimensions shown are approximate.
Colour Television
Specification
Order No. MTV0501350C3
 1 Safety Precautions 
3
 1.1. 
General Guide 
3
 1.2. 
Leakage Current Cold Check 
3
 1.3. 
Leakage Current Hot Check (See Fig. 1) 
3
 1.4. 
X-Radiation 
3
 1.5. 
GP2 Block Diagram 
4
 2 Service Hints 
5
 2.1. 
How to move chassis into service position 
5
 3 Market Mode Function 
6
 4 Adjustment Procedure 
7
 4.1. 
Adjustment Procedure 
7
 4.2. 
Colour Purity 
8
 4.3. 
Convergence 
8
 4.4. 
White Balance (Market Mode CHK 4) 
9
 4.5. 
Adjustment of CRT VRS 
10
 5 Conductor Views 
11
 6 Schematic Diagrams 
12
 6.1. 
Schematic Diagram for GP2 Chassis 
12
 6.2. 
D Board 
14
 6.3. 
G Board 
21
 6.4. 
L Board 
24
 6.5. 
A Board 
28
 7 Parts Location 
35
 8 Replacement Parts List 
36
 8.1. 
Replacement Parts List 
37
CONTENTS
 Page 
Page
2
TX-29F250T
1 Safety Precautions
1.1. General Guide
 1. It is advisable to insert an isolation transformer in the AC
supply before servicing a hot chassis. Fig. 1.
Fig. 1
 2. When servicing, observe the original lead dress, especially
the lead dress in the high voltage circuits. If a short circuit is
found, replace all parts which have been overheated or
damaged by the short circuit.
 3. After servicing, observe that all the protective devices such
as insulation barriers, insulation papers, shields, and
isolation R-C combinations, are properly installed.
 4. When the receiver is not to be used for a long period of
time, unplug the power cord from the AC outlet.
 5. Potential, as high as 32kV is present when this receiver is
in operation. Operation of the receiver without the receiver
power supply. Servicing should not be attempted by anyone
who is not thoroughly familiar with the precautions
necessary when working on high voltage equipment.
Always discharge the anode of the picture tube to the
receiver chassis before handling the tube.
After servicing make the following leakage current checks to
prevent the customer from being exposed to shock
hazards.
1.2. Leakage Current Cold Check
 1. Unplug the AC cord and connect a jumper between the two
prongs on the plug. Fig. 2.
Fig. 2
 2. Turn on the receiver’s power switch.
 3. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the receiver, such as screw heads, aerials,
connectors, control shafts, etc. When the exposed metallic
part has a return path to the chassis, the reading should be
between 4M
and 20M
. When the exposed metal does
not have a return path to the chassis, the reading must be
zero.
1.3. Leakage Current Hot Check
(See Fig. 1)
 1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
 2. Connect a 2 k
, 10 W resistor in series with an exposed
metallic part on the receiver and an earth such as a water
pipe.
 3. Use an AC voltmeter, with high impedance type, to
measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the
voltage at each point. Fig. 3.
Fig. 3
 5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
 6. The potential any point should not exceed 1.0V rms. In the
case of a measurement being outside of the limits specified,
there is a possibility of a shock hazard, and the receiver
should be repaired and re-checked before it is returned to
the customer. Fig. 4.
Fig. 4
1.4. X-Radiation
Warning :
 1. The potential sources of X-Radiation in TV sets are the EHT
section and the picture tube.
 2. When using a picture tube test rig for service, ensure that
the rig is capable of handling 30 kV without causing X-
Radiation.
Note: It is important to use an accurate periodically calibrated
high voltage meter.
 1. Set the brightness to minimum.
 2. Measure the High Voltage. The meter reading should
indicate 31.0 ± 1.0kV. If the meter indication is out of
tolerance, immediate service and correction is required to
prevent the possibility of premature component failure.
 3. To prevent the possibility of X-Radiation, it is essential to
use the specified picture tube.
3
TX-29F250T
1.5.
 GP2
Block
Diagram
 
 
A
ntenna
 
 
defl
.
coil
CRT
 
TUNER
R
G
B
VM
AV1
AV2
AV3
AV4
 
   VIDEO
  SWITCH
  Y
U
V
V
A
 VSP
IC1501
CVBS
  IN
CVBS
 OUT
V
H
Y
U
V
Y
U
V
V
H
MON
OUT
Y
U
V
R
G
B
EW
H
BLK
R/G/B
V
  DDP
IC1701
CVBS
SIF
MONITOR
OUT
SIF
A IN
MON OUT
L OUT
R OUT
L
R
PRIMARY
LIFE CCT
T849
SW TRAN
IC853 
3.3V & 2.5V
IC880
9V
IC852
5V
IC856
3.3V
MICON
IC1101
BLK
R/G/B
SCL
SDA
EPROM
IR
 EXT
ROM
  TXT
CVBS
MSP
Audio
Amp
L
R
GEOMAGNETIC
V OUT
H OUT
VM
4
TX-
29F25
0T
Page of 45
Display

Panasonic TX-29F250T Service Manual ▷ Download

  • DOWNLOAD Panasonic TX-29F250T Service Manual ↓ Size: 4.82 MB | Pages: 45 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic TX-29F250T in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic TX-29F250T TV. Information contained in Panasonic TX-29F250T Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.