DOWNLOAD Panasonic TC-21PM30RQ Service Manual ↓ Size: 33 MB | Pages: 30 in PDF or view online for FREE

Model
TC-21PM30RQ
Pages
30
Size
33 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
tc-21pm30rq.pdf
Date

Panasonic TC-21PM30RQ Service Manual ▷ View online

2 Service Hints
2.1. Service Position for E-Board
 1. Remove the back cover.
 2. Stand the TV set as shown in Fig. 2.
 3. Remove the A-Board from the TV set by pulling the main board out as shown in Fig. 2.
Fig. 2
2.2. Factory Mode Adjustment
How to set :
To set the Factory mode, press Volume 0 dac on the TV and Timer Setting 30 min on
the remote control and press Volume (-) Down button on the TV together press recall on
the remote control.
CHK should appear on right of TV screen.
To move from CHK1 to CHK2 mode, etc. please follow below rotation :
To Set Self-Check :
Press the Volume Down button on TV then press the Off Timer button on remote
control.
5
TC-21PM30RQ
2.3. Adjustment for White Balance
Preparation:
 1. Receive the white balance pattern and aging should have been performed over 30 minutes.
 2. Set the picture menu to DYNAMIC NORMAL.
 3. Degausse the CRT face.
 4. Fix the CRT colour analyzer receiver unit to CRT face.
Adjustment of Low Light.
 1. Adjustment Sub Bright, so that Y = 6.3 ± 1.0 nit.
 2. Adjustment R-CUT OFF, so that X = 0.235 ± 0.010 nit.
 3. Adjustment G-CUT OFF, so that Y = 0.235 ± 0.010 nit.
Adjustment of High Light
 1. Adjustment Sub Bright, so that Y = 270 nit.
 2. Adjustment R-Drive, so that X = 0.265 ± 0.010 nit.
 3. Adjustment B-Drive, so that Y = 0.265 ± 0.010 nit.
2.4. Adjustment for CRT CUT OFF
Preparation:
 1. Connect the oscilloscope probe to TPL7.
 2. Screen VR min.
 3. Set the data Sub Bright, Bright.
 4. In service Mode at “Bright” dac press [5] in factory mode to enter vertical line and adjust by Volume Down or Up button.
 5. Adjust “Screen VR” until 1-H Line appears.
6
TC-21PM30RQ
2.5. Adjustment Procedure
Item / Preparation
Adjustment Procedure
+B Voltage
Confirm the DC voltage at the indicated test points, as follows :
1. Operate the TV set.
TPA 12 : 140.5 ± 1.5V
2. Set control as follows :
TPA 11 : 8 ± 1V
Brightness ...........minimum
TPA 10 : 5 ± 1V
Contrast .............. minimum
TPA 21 : 215 ± 15V
RF AGC
1. Receive a colour bar signal at an RF level of 74+1-
2 dBU with 75
loaded.
1. Select “RF AGC” indication in CHK2, on Screen by remote control at factory
mode.
2. Connect digital multimeter to RF AGC at Tuner.
2. Set RF AGC by using remote control Volume (+) or Volume (-) button until voltage
AGC at Tuner reaches 2.6 ± 0.1V at TPA 15 (Tuner point).
3. Increase RF signal strength by 2dB, confirm AGC at Tuner voltage drop.
High Voltage
1. Receive the crosshatch pattern.
1. Connect a DC voltage meter to TPA 20 and confirm the +B voltage is 140.5 ±
1.5V.
2. Set to 0 Beam.
Screen VR .......... minimum
2. Connect a high frequency voltmeter to heater and confirm that voltage reads 6.0
± 0.24 (VRMS).
Contrast .............. minimum
3. Normalize the brightness and contrast.
Item / Preparation
Adjustment Procedure
NTSC TINT COLOUR
Connect a short jumper between TPA 10 and TPA
20.
Press Main Menu and set system to use AV-NTSC
(3.58 MHz).
DYNAMIC ................. Normal
Channel CLR Set ..... STD
1. Adjust Sub-Tint so that No. 2, 3 and 4 becomes level waveform is similar to Fig.
3.
2. Confirm phase at Tint is changes more than ± 30 by Tint control.
3. Confirm that colour level is maximum when colour DAC is adjusted to maximum
position.
Note: Use remote control only when adjusting user mode to Sub-Tint.
Fig. 3
7
TC-21PM30RQ
2.7. Adjustment
2.6. PAL Colour
 1. Receive the PAL B/G studio colour bar pattern and adjust local frequency at the best tuned position.
 2. Pic Menu: Dynamic Normal, Confirm Contrast - 63, Sub Contrast - 21.
 3. Channel colour set --------- STD.
 4. “CHK2” and press digit key “5” (AKB OFF) also confirm OSD become blue colour.
 5. Connect TPA 10 to TPA 20.
 6. Set (A) to 2.3 ± 0.2V by BRT (CHK2) at measurement point TPL 2 Fig. 4.
 1. Connect oscilloscope probe to TPL 2 (G OUT) with 10k
series resistor and adjust Contrast so that (B) as in Fig. 4 is 2.6 ± 0.1V.
 2. Adjust “Sub Colour” so that waveform as in Fig. 4 (1) 2.5 ± 0.1V.
 3. Connect oscilloscope probe to TPL 1 (R OUT) with 10k
series resistor and confirm waveform as in Fig. 5 is (2) 2.7 ± 0.4V.
 4. Take out jumper TPA 10 and TPA 20.
 5. Press digit key “5” (AKB ON) and confirm the OSD become white colour.
8
TC-21PM30RQ
Page of 30