- 9 -
Pincushion Adjustment Mode (CHK3)
White Balance Adjustment Mode (CHK4)
Note: Picture will be Changed to the one horizontal line by pressing “5” of 10 key button in the item “  
  “.
No.
Display
Adj. Range
Average Data 
& Fixed [( ) 
mark] Data
Items
1
50 V-HEIGHT
00H-7FH
49H
Vertical Height (50Hz)
2
60 V-HEIGHT
00H-7FH
4CH
Vertical Height (60Hz)
3
PARABOLA
00H-3FH
0AH
Parabola
4
H-WIDTH
00H-3FH
25H
Horizontal Width
5
50 VS CORRECT
00H-3FH
0DH
Vertical S Curve Correction (50Hz)
6
60 VS CORRECT
00H-3FH
16H
Vertical S Curve Correction (60Hz)
7
V-LINEAR
00H-3FH
2EH
Vertical Linearity
8
TRAPEZOID
00H-3FH
20H
Trapezoid
9
EW-CORNER1
00H-0FH
07H
EW-Corner1 (Bottom)
10
EW-CORNER2
00H-0FH
07H
EW-Corner2 (Top)
11
50 H CENTER
00H-1FH
0CH
Horizontal Center (50Hz)
12
V-CENTER
00H-07H
02H
Vertical Center
No.
Display
Adj. Range
Average Data 
& Fixed [( ) 
mark] Data
Items
1
R-CUT
00H-FFH
74H
Red Cut off
2
G-CUT
00H-FFH
7FH
Green Cut off
3
B-CUT
00H-FFH
8AH
Blue Cut off
4
BRIGHT
0-63
33
Bright (the same as user control)
5
SUB BR
00H-FFH
43H
Sub Bright
6
R-DR
00H-FFH
7AH
Red Drive
7
B-DR
00H-FFH
77H
Blue Drive
- 10 -
Pincushion Adjustment (CHK3)
50Hz/60Hz V-HEIGHT
UP
DOWN
PARABOLA
H-WIDTH
50Hz/60Hz V-S CORRECT
V-LINEAR
TRAPEZOID
EW-COENER1
EW-COENER2
50Hz H-CENTER
V-CENTER
- 11 -
Adjustment Procedure
Item / Preparation
Adjustment Procedure
B Voltage
1. Operate the TV set.
2. Set controls :
Bright..................
minimum
Sub Bright...........
minimum
Volume................
minimum
1. Confirm that the indicated test points for the specified voltage:
TPA140 : 115.0   ±
2.0 V
TPA12 :   12.0 ±
1.0 V
TPA05   :     5.0  ±
1.0V
TPA09 :      9.0 ±
1.0V
TPA32   :     5.0  ±
1.0V
TPA220 :   21.5  ±
1.5V
RF AGC
1. By using spectrum & attenuator ensure
the RF signal input to the TV is 69dBU
(75 
W
open).
2. Connect digital multimeter to TPA20.
1. Select "RF AGC" indication in CHK2. ON Screen by remote control
at factory mode.
2. Set RF AGC by control volume (-) or (+) at voltage TPA 20 reach
2.6 ± 0.3V.
3. Increase RF signal strength by 2dB. Confirm TPA20 voltage drop.
EHT & HEATER
1. After H-WIDTH Rough Adjustment.
2. Receive the crosshatch pattern.
3. Set to 0 beam.
(screen VR :MIN.   CONTRAST :MIN.)
1. Connect DC voltage meter to D831 Cathode and confirm that +B
voltage is 142.0 ± 2V.
2. Connect High frequency voltmeter to heater, and confirm that voltage
reads                          6.3 ± 0.24 (VRMS)
3. Connect High voltage meter to CRT anode, and confirm that high
voltage is less than 28.5 (+0.7, -1.5)V .
SUB CONTRAST
  
1. Connect oscilloscope probe to TPA41 (G OUT).
2. Receive the PAL colour bar pattern, and
adjust local frequency at the best tuned
position.
3. Connect short-jumper to TPA57 and
TPA50.
4. Connect short-jumper to FBT pin3 and
TPA32.
5. Picture menu : DYNAMIC NORMAL.
AI                   : OFF
Channel colour SET....STD.
6. Set to 2.3 ± 0.2V by BRIGHT.
1. Adjust  Sub-Contrast, so that waveform is 2.5 ± 0.1Vp-p as shown.
PAL COLOUR OUTPUT
  
1. Receive the PAL colour bar pattern, and
adjust local frequency at the best tuned
position.
2. Connect short-jumper to TPA57 and
TPA50.
3. Connect short-jumper to FBT pin3 and
TPA32.
4. Picture menu : DYNAMIC NORMAL.
AI                   : OFF
Channel colour SET....STD.
5. Set to 2.3 ± 0.2V by BRIGHT.
1. Connect oscilloscope prebe to TPA41 (G OUT) and adjust SUB
COLOUR, so that waveform is 2.5 ± 0.1Vp-p as in Fig.1.
2. Connect oscilloscope prebe to TPA40 (R-OUT) and conform the
waveform is 3.2 ± 0.5Vp-p as in Fig.2. 
2.5±0.1Vp-p
2.3±0.2V
0V
2.5±0.1Vp-p
2.3±0.2V
Fig.1
Fig.2
0V
3.2±0.5Vp-p
2.3±0.2
- 12 -
Item / Preparation
Adjustment Procedure
NTSC SUB-TINT
  
1. Connect oscilloscope probe to TPA40 (R OUT).
2. Input Rainbow-Pattern (3.58MHz NTSC)
to VIDEO-IN terminal, and set AV mode by
TV/AV select button.
3. Connect short-jumper to TPA57 and
TPA50.
4. Connect short-jumper to FBT pin3 and
TPA32.
5. Picture menu : DYNAMIC NORMAL.
AI                   : OFF
Channel colour SET....STD.
1. Adjust  Sub-NTSC-TINT, so that levels of NO.2, NO.3, NO4 (Fig.1)
become Fig,2.
2. Confirm the waveform is 1.3Vp-p.
SECAM BLACK LEVEL
  
1. Receive the SECAM colour bar pattern.
Input RF signal level : 75dB
(75 
W
 opened).
2. Picture menu : DYNAMIC NORMAL.
AI                   : OFF
3. Channel colour SET....STD.
4. Enter factory mode, then go to CHK2.
5. Connect short jumper from FBT pin 3 to
TPA32.
1. Press digit '4' until R-Y appears.
2. Connect oscilloscope prebe to TPA52 (R-Y out).
3. Connect oscilloscope prebe ground to TPA54 (IC601 pin 32. gnd).
4. Adjust R-Y so that point A and point B center line are flat. See Fig.1.
5. Connect oscilloscope prebe to TPA53 (B-Y out). Press digit '4' until B-Y
appears.
6. Adjust B-Y so that point C and D center line are flat. See Fig.2. 
1
2
3
4
5
6
Fig.1
Fig.2
7
8
9
10
A
B
2
3
4
A : B = 2 : 3
A
B
C
Fig.2
Fig.1
D
Page of 38