Panasonic TC-15PM30R Service Manual ▷ View online
Pal Colour
1. Receive the PAL B/G studio colour bar pattern, and adjust local frequency at the best tuned
position.
2. Pic Menu : Dynamic Normal , Confirm Contrast - 63 , Sub Contrast - 21.
3. Channel colour set ----------- STD.
4. Connect TPA 10 to TPA 20.
5. Set (A) to 2.3 +- 0.2V by BRT (CHK2) Fig. 1.
position.
2. Pic Menu : Dynamic Normal , Confirm Contrast - 63 , Sub Contrast - 21.
3. Channel colour set ----------- STD.
4. Connect TPA 10 to TPA 20.
5. Set (A) to 2.3 +- 0.2V by BRT (CHK2) Fig. 1.
Adjustment
1. Connect oscilloscope probe to TPA 31 (G OUT) with 10k series resistor and adjust Contrast so
that (B) as in Fig.1 is 2.8 +- 0.1V.
2. Adjust ‘Sub Colour’ so that waveform as in Fig.1 (1) 2.5 +- 0.1V.
3. Connect oscilloscope probe to TPA 32 (R OUT) with 10k series resistor and confirm waveform as in
Fig.2 is (2).2.7 +- 0.4V
that (B) as in Fig.1 is 2.8 +- 0.1V.
2. Adjust ‘Sub Colour’ so that waveform as in Fig.1 (1) 2.5 +- 0.1V.
3. Connect oscilloscope probe to TPA 32 (R OUT) with 10k series resistor and confirm waveform as in
Fig.2 is (2).2.7 +- 0.4V
Fig. 1
Fig. 2
B
1
A
2
A
0V
Before Colour Purity, Convergence and White Balance adjustment are attempted,
V. Height, H. Centre and Focus adjustments must be completed.
V. Height, H. Centre and Focus adjustments must be completed.
Colour Purity
Convergence
1. Set the Brightness and Contrast controls to
1. Apply a crosshatch pattern signal and
their maximum postions.
Normalize Contrast control to the
2. Operate the TV set for 30 minutes.
maximum positions.
3. Fully degauss the picture tube by using an
2. Adjust Brightness until the grey position of
external degaussing coil.
the crosshacth pattern just becomes black.
4. Apply a crosshatch pattern signal and adjust
3. Adjust the Red and Blue line at the centre of
the static convergence magnets to the
the screen by rotating the R-B static
approximately correct position.
5. Receive a black and White signal.
6. Set the control as following:
6. Set the control as following:
Red ................ minimum
Green ............. minimum
Blue ............... minimum
Green ............. minimum
Blue ............... minimum
Press the Shipping button on the remote control
twice to select CRT Adjustment Mode as per
Fig. 16 to select low light.
twice to select CRT Adjustment Mode as per
Fig. 16 to select low light.
7. Loosen the clamp screw for the deflection yoke
A in Fig. 24 and move the deflection yoke as close
to the purity magnet as possible.
to the purity magnet as possible.
8. Adjust the purity magnetic rings so that a vertical
green field is obtained at the cntre of the screen.
Fig.22
4. Adjust Red and Blue with Green line at
4. Adjust Red and Blue with Green line at
centre of the screen by rotating (RB) -G
static convergence magnetic rings.
static convergence magnetic rings.
5. Lock convergence magnetic with silicne
sealer.
6. Remove the DY wedges and slightly tilt the
sealer.
6. Remove the DY wedges and slightly tilt the
deflection yoke vertically and horizontally to
obtain the good overall convergence.
obtain the good overall convergence.
Fig.20
9. Slowly push the deflection yoke and set it where
a uniform green field is obtained.
10. Re-adjust the Low Light controls to their correct set-
tings and make sure that a uniform white field is
obtained.
obtained.
7. Fix the deflection yoke by re-inserting the DY
11. Tighten the clamp screw A in Fig. 24.
wedges.Refer to Fig. 24.
8. If purity error is found, repeat “Colour
Purity” adjustment.
Purity” adjustment.
Slide magnetic tabs toward or away from
each other.
R-B Static
Convergence Magnet
Convergence Magnet
Vertical
Convergence
Red & Blue
Horizontal
Convergence
Convergence
Red & Blue
Rotate both magnetic rings together.
R-B Static
Convergence Magnet
Convergence Magnet
Vertical
Horizontal
RGB
R
G
B
R
G
B
BGR
BGR
Purity Magnet Green Field
Colour Purity
Green
Uniform
green
Fig. 21
Fig. 23
Fig. 24
Fig. 25
Note :
1. Wedge A,B and C should be inserted following the sequence of 1,2 and 3 shown
in Fig. 25.
2. The wedges should be set 120 apart from each other.
3. Be certain that four wedges are firmly fixed and the Deflection Yoke is tightly clamped
in place.
Otherwise the Deflection Yoke may shift its position and cause a loss of convergence
and purity.
Otherwise the Deflection Yoke may shift its position and cause a loss of convergence
and purity.
24.5 mm
R-B Static
Convergence Magnet
Purity Magne
t
(RB)-G Static
Convergence Magnet
Clamp for
Convergence &
Purity Magnet
Convergence &
Purity Magnet
Deflection Yoke
°