DOWNLOAD Panasonic KX-TS2382RUB / KX-TS2382RUW Service Manual ↓ Size: 1.99 MB | Pages: 29 in PDF or view online for FREE

Model
KX-TS2382RUB KX-TS2382RUW
Pages
29
Size
1.99 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / INTEGRATED TELEPHONE SYSTEM
File
kx-ts2382rub-kx-ts2382ruw.pdf
Date

Panasonic KX-TS2382RUB / KX-TS2382RUW Service Manual ▷ View online

ORDER NO. KM40909012CE
Telephone Equipment
Model No.
KX-TS2382RUB
KX-TS2382RUW
Integrated Telephone System
B: Black Version
W: White Version
(for Russia)
2
KX-TS2382RUB/KX-TS2382RUW
3
KX-TS2382RUB/KX-TS2382RUW 
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions----------------------------------------------- 4
1.1. For Service Technicians --------------------------------- 4
2 Warning -------------------------------------------------------------- 4
2.1. About Lead Free Solder (Pbf: Pb free)--------------- 4
2.2. Discarding of P. C. Board-------------------------------- 5
3 Specifications ----------------------------------------------------- 6
4 Technical Descriptions ----------------------------------------- 7
4.1. Block Diagram---------------------------------------------- 7
4.2. Circuit Operation------------------------------------------- 8
5 Location of Controls and Components ------------------- 9
6 Installation Instructions ---------------------------------------- 9
7 Operating Instructions------------------------------------------ 9
7.1. For Service Hint-------------------------------------------- 9
8 Troubleshooting Guide ----------------------------------------10
8.1. Service Hints-----------------------------------------------10
8.2. Pulse Dialing Problems ---------------------------------10
8.3. Tone Dialing Problems ----------------------------------11
8.4. No Ringing Sound When Ring Signal is Input ---- 11
9 Disassembly and Assembly Instructions ---------------12
9.1. Disassembly Instructions -------------------------------12
10 Miscellaneous ----------------------------------------------------14
10.1. How to Replace the Flat Package IC ----------------14
10.2. Terminal Guide of the ICs, Transistors and
Diodes -------------------------------------------------------16
11 Schematic Diagram ---------------------------------------------17
11.1. For Schematic Diagram---------------------------------17
11.2. Schematic Diagram (Main)-----------------------------18
11.3. Schematic Diagram (Operation) ----------------------20
12 Printed Circuit Board-------------------------------------------21
12.1. Circuit Board (Main)--------------------------------------21
12.2. Circuit Board (Operation) -------------------------------23
13 Exploded View and Replacement Parts List -----------25
13.1. Cabinet and Electrical Parts ---------------------------25
13.2. Accessories -----------------------------------------------26
13.3. Replacement Part List-----------------------------------27
4
KX-TS2382RUB/KX-TS2382RUW
1 Safety Precautions
1.1.
For Service Technicians
• Repair service shall be provided in accordance with repair technology information such as service manual so as to pre-
vent fires, injury or electric shock, which can be caused by improper repair work.
1. When repair services are provided, neither the products nor their parts or members shall be remodeled. 
2. If a lead wire assembly is supplied as a repair part, the lead wire assembly shall be replaced. 
3. FASTON terminals shall be plugged straight in and unplugged straight out. 
• ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
1. Cover plastic parts boxes with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on worktable.
4. Do not grasp IC or LSI pins with bare fingers.
2 Warning
2.1.
About Lead Free Solder (Pbf: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that con-
tains lead.
We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn),
Silver (Ag), and Copper (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type of solder.
Caution
• PbF solder has a melting point that is 50 
°F ~ 70 °F (30 °C ~ 40 °C) higher than Pb solder. Please use a soldering iron with tem-
perature control and adjust it to 700 
°F ± 20 °F (370 °C ± 10 °C). 
• Exercise care while using higher temperature soldering irons.: 
Do not heat the PCB for too long time in order to prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100 
°F (600 °C).
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See the figure below).
Page of 29
Display

Panasonic KX-TS2382RUB / KX-TS2382RUW Service Manual ▷ Download

  • DOWNLOAD Panasonic KX-TS2382RUB / KX-TS2382RUW Service Manual ↓ Size: 1.99 MB | Pages: 29 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic KX-TS2382RUB / KX-TS2382RUW in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic KX-TS2382RUB / KX-TS2382RUW Telephone. Information contained in Panasonic KX-TS2382RUB / KX-TS2382RUW Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.