11.2.2. How to install Batch file into P.C.
Note:
“*****” varies depending on the country or models.
“*****” varies depending on the country or models.
11.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
98” is written.
hookoff
Off-hook mode on Base
Type “hookoff”.
hookon
On-hook mode on Base
Type “hookon”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
is data to be written.
1.
Insert the Batch file CD-ROM into CD-ROM drive and
copy PNZZTG**** folder to your PC (example: D drive).
2.
Open an MS-DOS mode window.
3.
At the DOS prompt, type "D:" (for example) to select the
drive, then press the Enter key.
4.
Type "CD
㪳PNZZTG****", then press the Enter key.
5.
Type "SET_COM=X", then press the Enter key
(X: COM port number used for the serial connection on your PC).
6.
Type "READID", then press the Enter key.
䊶If any error messages appear, change the port number or
䇭check the cable connection.
䊶If any value appear, go to next step.
7.
Type "DOSKEY", then press the Enter key.
<Example>
C:
>Documents and Settings>D:
D:
>>CD >PNZZTG****
D:
>PNZZTG**** >SET_COM=X
D:
>PNZZTG****>READID
00 52 4F A8 A8
D:
D:
>PNZZTG****>DOSKEY
D:
>PNZZTG****>
<Example: error happens>
C:
>Documents and Settings>D:
D:
>>CD >PNZZTG****
D:
>PNZZTG**** >SET_COM=X
D:
>PNZZTG****>READID
ޓCreateFile error
ERROR 10: Can't open serial port
D:
ERROR 10: Can't open serial port
D:
>PNZZTG ****>
<Example for Windows>
On your computer, click [Start], select Programs
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
50
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
11.3. Adjustment Standard (Base Unit)
When connecting the simulator equipment for checking, please refer to below.
11.3.1. Bottom View
Note:
(*1) is referred to No.2 of Check Table for RF part (P.34)
(*2) is referred to Power Supply Circuit/Reset Circuit (P.11)
(*2) is referred to Power Supply Circuit/Reset Circuit (P.11)
PbF
PNLB2387Z*
KX-TGC3xxH
R T C K
R S T N
V C C A
DCM
DCP
C601
+ 3 . 0 V
C611
S A 1 0 1
S A 1 0 2
S A 1 0 2
C H G +
C H G -
F301
ANT1
TCK
UGND
Q111
ANT1_Short
U R X
TDI
TDO
Q701
Q702
U T X
S T M / C K M / P 1 5
Q 1 4 0
I C 6 0 1
Q 1 4 2
I C 6 1 1
R 1 0 3
R 1 0 4
R111
R112
R 1 1 3
R114
R121
R122
R123
R124
R701
R702
R511
R 3 2 1
R 3 2 2
C 1 0 3
C 1 0 4
GAP
R142
R144
R145
R148
R149
C110
C 1 1 2
C 1 1 3
R924
V D D C
TMS
L 1 R
C 1 2 0
L 1 T
C121
C122
C513
C515
C 3 2 1
+5.5V
RA611
R371
C141
R372
C143
C 3 4 2
C351
D 1 1 3
V R E F
IC302
ANT1_S-GND
D 3 6 2
J O I N T 2
C343
A
ANT1 Short
TEL
Digital
Volt Meter
12
2W
CHG-
CHG+
DC
+3.0V (B)
VBAT (A)
Frequency
Counter
CKM
GND
(E)
(N)
DECT Tester
CTS60
(H)(I)(J)(K)(L)
Jig
TX
RX
(B)(C)(D)(E)(F)(H)(O)
PC
GND
51
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
11.4. The Setting Method of JIG (Handset)
This section explains the PC setting to use command required in Check Point (Handset)(P.41).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: Refer to parts list of Fixtures
• PC which runs in DOS mode
• Batch file CD-ROM for setting: Refer to parts list of Fixtures
and Tools (P.83).
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.4.1. Connections
Connect the DC Power or Battery to BATT+ and BATT-.
Connect the JIG cable GND (black) to GND.
Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX.
Connect the JIG cable GND (black) to GND.
Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX.
Note:
*: COM port names may vary depending on what your PC calls it.
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
) New value (k)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
DC Power
or Battery
1
BATT-
BATT+
2
GND (black)
3
To Serial Port
(com port 1*)
(com port 1*)
JIG Cable
PC
URX
(yellow)
3
UTX
(red)
GND
UTX
URX
52
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
11.4.2. How to install Batch file into P.C.
Note:
• “*****” varies depending on the country or models.
11.4.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
98” is written.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
is data to be written.
1.
Insert the Batch file CD-ROM into CD-ROM drive and
copy PNZZTG***** folder to your PC (example: D drive).
2.
Open an MS-DOS mode window.
3.
At the DOS prompt, type "D:" (for example) to select the
drive, then press the Enter key.
4.
Type "CD
㪳PNZZTG*****", then press the Enter key.
5.
Type "SET RTX_COM=X", then press the Enter key
(X: COM port number used for the serial connection on your PC).
6.
Type "READID", then press the Enter key.
䊶If any error messages appear, change the port number or
䇭check the cable connection.
䊶If any value appear, go to next step.
7.
Type "DOSKEY", then press the Enter key.
<Example>
C:
>Documents and Settings>D:
D:
>>CD >PNZZTG*****
D:
>PNZZTG***** >SET RTX_COM=X
D:
>PNZZTG*****>READID
00 52 4F A8 A8
D:
D:
>PNZZTG*****>DOSKEY
D:
>PNZZTG*****>
<Example: Error happens>
C:
>Documents and Settings>D:
D:
>>CD >PNZZTG*****
D:
>PNZZTG***** >SET RTX_COM=X
D:
>PNZZTG*****>READID
ޓCreateFile error
ERROR 10: Can't open serial port
D:
ERROR 10: Can't open serial port
D:
>PNZZTG*****>
<Example for Windows>
On your computer, click [Start], select Programs
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
Click on the first or last page to see other KX-TGC310RU / KX-TGC312RU / KX-TGC320RU / KX-TGC322RU / KX-TGC310UC / KX-TGC312UC / KX-TGC320UC / KX-TGCA30RU service manuals if exist.