KX-TG8521UAB/KX-TGA850RUB
(F)* Battery Monitor Check
-
1. Apply 2.35 V between BATT+ and BATT-.
2. Execute the command 
sendchar VBA
It assumes that the return value is XX.
a) XX < 0A: No need to adjust
Note:
b) XX   0A : Reject
IC1, F1, C2, 
R45, C15, C80
(G)
Battery Low Confirma-
tion
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.35 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
IC1, F1, C2, 
R45, C15, C80
(H)* BBIC Clock Adjustment
CLK
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (13.824000 MHz ± 100 Hz).
4. If the frequency is not 13.824000 MHz ± 100 Hz, adjust the frequency of CLK
executing the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 13.824000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of “3” “5” “7” “#” clears the registration.
Register to it on Base Unit after measurement. 
IC1, X1, C8, 
C9, R64
 
(I)* Transmitted Power Con-
firmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1, 
C802~C806, 
C808~C814, 
C819, C822, 
C825~C827, 
C834, C860, 
C861, L801, 
L803, DA801, 
R801, R802, 
R805~R807
(J)*
Modulation Check
-
Follow steps 1 to 3 of (I).
4.Confirm that the B-Field Modulation is -340±30/ +340±30 kHz/div & Modulated
width   660 kHz using data type Fig 31.
IC1, 
C802~C806, 
C808~C814, 
C819, C822, 
C825~C827, 
C834, C860, 
C861, L801, 
L803, DA801, 
R801, R802, 
R805~R807
(K)* Frequency Offset Confir-
mation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 50 kHz.
IC1, 
C802~C806, 
C808~C814, 
C819, C822, 
C825~C827, 
C834, C860, 
C861, L801, 
L803, DA801, 
R801, R802, 
R805~R807
(L)* Frequency Drift Confir-
mation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 35 kHz/ms.
IC1, 
C802~C806, 
C808~C814, 
C819, C822, 
C825~C827, 
C834, C860, 
C861, L801, 
L803, DA801, 
R801, R802, 
R805~R807
Items
Check 
Point
Procedure
Check or 
Replace Parts
<
=
42
KX-TG8521UAB/KX-TGA850RUB
(M)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1, 
C802~C806, 
C808~C814, 
C819, C822, 
C825~C827, 
C834, C860, 
C861, L801, 
L803, DA801, 
R801, R802, 
R805~R807
(N)* Power RAMP Confirma-
tion
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1, 
C802~C806, 
C808~C814, 
C819, C822, 
C825~C827, 
C834, C860, 
C861, L801, 
L803, DA801, 
R801, R802, 
R805~R807
(O) Audio Check and Confir-
mation
-
1. Link to BASE which is conected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm (600 
Ω)/1kHz to MIC of Handset.
Measure the Level at Line I/F and distortion level.
4. Confirm that the level is -7 dBm ± 2 dBm and that the distortion level is < 5% at
TEL Line (600 
Ω Load).
5. Input -20 dBm (600 
Ω)/1 kHz to Line I/F.
Measure the level at Receiver of Handset and distortion level
(Receive volume set to second position from minimum). 
6. Confirm that the level is -23 dBm ± 2 dBm and that the distortion level is < 5%
at Receiver (34 
Ω Load).
IC1, C12, C96,
C97, R25, L3, 
C86, R24, 
CN4, L72, 
C14, R306, 
L74, C17, 
C110, C185, 
C82, C83, 
C152, R152, 
C188, R27, 
RA4, C11, 
C13, R28, 
MIC, C113, 
R34
(P) SP phone Audio Check 
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -25 dBm (600 
Ω)/1KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -5 dBm ± 2 dBm and that the distortion level is < 5%.
(vol = 3)
IC1, C12, C73, 
D13, D14, 
R73, R74, 
MIC, C11, 
C13, RA4, 
R27, R28, 
C96, C97, L13, 
R24, R152, 
C188, R34, 
C113
(Q)
DouBout 3.0V Supply 
Confirmation
3.0V
1. Confirm that the voltage between testpoint 3.0V and GND is 3.0V ±0.2V.
C30
Items
Check 
Point
Procedure
Check or 
Replace Parts
43
KX-TG8521UAB/KX-TGA850RUB
10 Disassembly and Assembly Instructions
10.1. Disassembly Instructions
10.1.1. Base Unit
Ԙ
Remove the 4 screws to remove
the cabinet cover.
ԙ
Remove the tapes and solders.
Ԛ
Remove the parallel wire to remove
the main P.C. board.
 Cabinet cover
Ԙ
4 screws
Tapes and solders
ԙ
Ԛ
Parallel wire
Main P.C. board
44
KX-TG8521UAB/KX-TGA850RUB
ԛ
Remove the 4 screws to
remove the operational P.C. board.  
       
Operational P.C. board
ԛ
4 screws
Page of 90
Display

Click on the first or last page to see other KX-TG8521UAB / KX-TGA850RUB (serv.man2) service manuals if exist.