DOWNLOAD Panasonic KX-TG8301RUB / KX-TG8301RUJ / KX-TG8301RUT / KX-TG8301RUW / KX-TG8302RUB / KX-TG8302RUJ / KX-TG8302RUT / KX-TGA830RUB / KX-TGA830RUJ / KX-TGA830RUT / KX-TGA830RUW Service Manual ↓ Size: 2.88 MB | Pages: 102 in PDF or view online for FREE

Model
KX-TG8301RUB KX-TG8301RUJ KX-TG8301RUT KX-TG8301RUW KX-TG8302RUB KX-TG8302RUJ KX-TG8302RUT KX-TGA830RUB KX-TGA830RUJ KX-TGA830RUT KX-TGA830RUW
Pages
102
Size
2.88 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg8301rub-kx-tg8301ruj-kx-tg8301rut-kx-tg8301ru.pdf
Date

Panasonic KX-TG8301RUB / KX-TG8301RUJ / KX-TG8301RUT / KX-TG8301RUW / KX-TG8302RUB / KX-TG8302RUJ / KX-TG8302RUT / KX-TGA830RUB / KX-TGA830RUJ / KX-TGA830RUT / KX-TGA830RUW Service Manual ▷ View online

53
KX-TG8301RUB/KX-TG8301RUJ/KX-TG8301RUT/KX-TG8301RUW/KX-TG8302RUB/KX-TG8302RUJ/KX-TG8302RUT/KX-TGA830RUB/KX-TGA830RUJ/KX-TGA830RUT/KX-TGA830RUW
(K)* Frequency Offset Confir-
mation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 50 kHz.
IC1, 
C808~C814, 
L802~L804, 
C825, C834, 
C819, IC801, 
R107, R108, 
C117, C118, 
C841, C125, 
C842, DA1, 
C801~C804, 
D801,D802, 
C837, C826, 
C822, C820, 
C832, C833, 
R801~R807
(L)* Frequency Drift Confir-
mation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 35 kHz/ms.
IC1, 
C808~C814, 
L802~L804, 
C825, C834, 
C819, IC801, 
R107, R108, 
C117, C118, 
C841, C125, 
C842, DA1, 
C801~C804, 
D801,D802, 
C837, C826, 
C822, C820, 
C832, C833, 
R801~R807
(M)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1, 
C808~C814, 
L802~L804, 
C825, C834, 
C819, IC801, 
R107, R108, 
C117, C118, 
C841, C125, 
C842, DA1, 
C801~C804, 
D801,D802, 
C837, C826, 
C822, C820, 
C832, C833, 
R801~R807
(N)* Power RAMP Confirma-
tion
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1, 
C808~C814, 
L802~L804, 
C825, C834, 
C819, IC801, 
R107, R108, 
C117, C118, 
C841, C125, 
C842, DA1, 
C801~C804, 
D801,D802, 
C837, C826, 
C822, C820, 
C832, C833, 
R801~R807
(O) Audio Check and Confir-
mation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 40 mA.
3. Input -45 dBm/1KHz to MIC and measure Line output level.
4. Confirm that the level is -10 dBm ± 2 dBm and that the distortion level is < 5%
at TEL Line (600 
Ω Load).
5. Input -20 dBm/1KHz to Line I/F and measure Receiving level at REV+ and
REV-.
6. Confirm that the level is -21 dBm ± 2 dBm and that the distortion level is < 5%
at Receiver. (vol = 1)
IC1, R23, C12, 
D19, D20, 
C96, C97, 
R215, R27, 
RA4, C11, 
C13, R28, D3, 
D4, L10, L11, 
MIC
Items
Check 
Point
Procedure
Check or 
Replace Parts
54
KX-TG8301RUB/KX-TG8301RUJ/KX-TG8301RUT/KX-TG8301RUW/KX-TG8302RUB/KX-TG8302RUJ/KX-TG8302RUT/KX-TGA830RUB/KX-TGA830RUJ/KX-TGA830RUT/KX-TGA830RUW
9.3.2.
Troubleshooting for Speakerphone
When the customer’s telephone line corresponds to the following conditions, and the transmission signal of SP-Phone is 
interrupted, performing the next set up to a cordless handset will improve it to some extent.
Conditions
1. When customer’s line has less line loss.
ex.) The customer is using optical fiber, ISDN terminal adaptor, or PBX.
In this case, receiving signal is strong and it may affect transmission signal.
2. When the other party is talking from noisy place.
ex.) The other party is using cellular phone. The background noise is very loud.
In this case, the noise from the other party (i.e. surrounding noise) may affect transmission signal.
Setting Method
• Change the handset address of EEPROM (0129) from 00 to 01 by Engineering Mode.
(P) SP phone Audio Check 
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 40 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -25 dBm/1KHz to Line I/F and measure Receiving level at SP+ and SP-.
5. Confirm that the level is -13 dBm ± 2 dBm and that the distortion level is < 5%.
(vol = 3)
IC1, R23, C12, 
C73, D13, 
D14, R152, 
C80, L10, L11, 
MIC, C11, 
C13, RA4, 
R27, R28, 
C96, C97, 
R215, C72
(Q) Charge Pump 2.5V Sup-
ply Confirmation
CP2.5V
1. Confirm that the voltage between testpoint and CP2.5V and GND is 2.5V -0.1/
+0.3V.
C52, C53, C49
(R)
Change Pump 4.0V 
Supply Confirmation
CP4.0V
1. Confirm that the voltage between testpoint CP4.0V and GND is 4.0V I0.2V.
C50, C51
Items
Check 
Point
Procedure
Check or 
Replace Parts
55
KX-TG8301RUB/KX-TG8301RUJ/KX-TG8301RUT/KX-TG8301RUW/KX-TG8302RUB/KX-TG8302RUJ/KX-TG8302RUT/KX-TGA830RUB/KX-TGA830RUJ/KX-TGA830RUT/KX-TGA830RUW
9.4.
How to Replace the Flat Package IC
Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a
soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
9.4.1.
Preparation
• PbF (: Pb free) Solder
• Soldering Iron
Tip Temperature of 700 
°F ± 20 °F (370 °C ± 10 °C)
Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with
less experience could overheat and damage the PCB foil.
• Flux
Recommended Flux: Specific Gravity 
→ 0.82.
Type 
→ RMA (lower residue, non-cleaning type)
Note: See About Lead Free Solder (Pbf: Pb free) (P.4)
9.4.2.
How to Remove the IC
1. Put plenty of solder on the IC pins so that the pins can be completely covered.
Note:
If the IC pins are not soldered enough, you may give pressure to the P.C. board when cutting the pins with a cutter.
2. Make a few cuts into the joint (between the IC and its pins) first and then cut off the pins thoroughly.
3. While the solder melts, remove it together with the IC pins.
When you attach a new IC to the board, remove all solder left on the board with some tools like a soldering wire. If some solder is
left at the joint on the board, the new IC will not be attached properly.
56
KX-TG8301RUB/KX-TG8301RUJ/KX-TG8301RUT/KX-TG8301RUW/KX-TG8302RUB/KX-TG8302RUJ/KX-TG8302RUT/KX-TGA830RUB/KX-TGA830RUJ/KX-TGA830RUT/KX-TGA830RUW
9.4.3.
How to Install the IC
1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins.
*Check the accuracy of the IC setting with the corresponding soldering foil.
2. Apply flux to all pins of the FLAT PACKAGE IC.
3. Solder the pins, sliding the soldering iron in the direction of the arrow.
9.4.4.
How to Remove a Solder Bridge
1. Lightly resolder the bridged portion.
2. Remove the remaining solder along the pins using a soldering iron as shown in the figure below.
Page of 102