DOWNLOAD Panasonic KX-TG8227UAB / KX-TG8227UAR / KX-TG8227UAW / KX-TGA820RUB / KX-TGA820RUR / KX-TGA820RUW / KX-TGA820UAB / KX-TGA820UAR / KX-TGA820UAW Service Manual ↓ Size: 2.84 MB | Pages: 101 in PDF or view online for FREE

Model
KX-TG8227UAB KX-TG8227UAR KX-TG8227UAW KX-TGA820RUB KX-TGA820RUR KX-TGA820RUW KX-TGA820UAB KX-TGA820UAR KX-TGA820UAW
Pages
101
Size
2.84 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS ANSWERING SYSTEM
File
kx-tg8227uab-kx-tg8227uar-kx-tg8227uaw-kx-tga820ru.pdf
Date

Panasonic KX-TG8227UAB / KX-TG8227UAR / KX-TG8227UAW / KX-TGA820RUB / KX-TGA820RUR / KX-TGA820RUW / KX-TGA820UAB / KX-TGA820UAR / KX-TGA820UAW Service Manual ▷ View online

45
KX-TG8227UAB/KX-TG8227UAR/KX-TG8227UAW/KX-TGA820RUB/KX-TGA820RUR/KX-TGA820RUW/KX-TGA820UAB/KX-TGA820UAR/KX-TGA820UAW
(G)* Hookswitch Check with 
DC Characteristics
-
1. Connect CN1 (Telephone Socket) to Tel-simulator which is connected with
600 
Ω.
2. Set line voltage to 48 V and line current to 40 mA at off-hook condition of nor-
mal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
L1, L2, Q3, R14, 
R15, Q4, R16, 
R17, IC7, D3
(H) DTMF Generator Check
-
1. Connect CN1 (Telephone Socket) to DTMF tester. (Road=600 
Ω)
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -3 ± 2 dBm.
5. Confirm that the low Group is -6 ± 2 dBm.
IC7, R116, 
C141, R29, C22, 
C23, R18~R24, 
C14~C17, Q5, 
D4
(I)* Transmitted Power Con-
firmation
-
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Short A_1 and GND.
• Test mode: FP
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70dBm.
2. Execute the command “testmode”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 20.7 dBm ~ 25.7 dBm.
IC7, IC10, L7, 
C117, C118, 
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
(J)* Modulation Check and 
Adjustment
-
Follow steps 1 to 6 of (I).
7.Confirm that the B-Field Modulation is +220 ~ +403/-220 ~ -403 kHz/div &
Modulated width   670 kHz using data type Fig31.
8.Adjust the B-Field Modulation if required. (Execute the command “readmod”
and “wrtmod xx”, where xx is the value.)
IC7, IC10, L7, 
C117, C118,  
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
(K)* Frequency Offset Check
-
Follow steps 1 to 6 of (I).
7.Confirm that the frequency offset is < ± 50 kHz.
IC7, IC10, L7, 
C117, C118,  
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
(L)* Frequency Drift Confir-
mation
-
Follow steps 1 to 6 of (I).
7.Confirm that the frequency drift is < ± 30 kHz/ms.
IC7, IC10, L7, 
C117, C118,  
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
(M)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 6 of (I).
7.Set DECT tester power to -90 dBm.
8.Confirm that the BER is < 1000 ppm.
IC7, IC10, L7, 
C117, C118,  
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
(N)*
Timing Confirmation
-
Follow steps 1 to 6 of (I).
7.Confirm that the Timing accuracy is < ± 5.0 ppm.
IC7, IC10, L7, 
C117, C118,  
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
Items
Check 
Point
Procedure
Check or 
Replace Parts
46
KX-TG8227UAB/KX-TG8227UAR/KX-TG8227UAW/KX-TGA820RUB/KX-TGA820RUR/KX-TGA820RUW/KX-TGA820UAB/KX-TGA820UAR/KX-TGA820UAW
9.2.2.
Check Point (Charger Unit)
Note:
After the measuring, suck up the solder of TP.
The connection of adjustment equipment is as shown in Adjustment Standard (Charger Unit) (P.62). 
(O)* Power RAMP Confirma-
tion
-
Follow steps 1 to 6 of (I).
7.Confirm that Power RAMP is matching.
IC7, IC10, L7, 
C117, C118,  
C124, C125, 
R106, R109, 
DA1, C112, 
R111, C126, 
C127, R112, 
R125, C128
(P)
Audio Check
-
1. Link with Handset.
2. Input -45 dBm/1kHz to MIC of Handset.
Measure the Level at Line I/F and distortion level.
3. Confirm that the level is -10 dBm ± 2 dBm and that the distortion level is < 5%
at TEL Line (600 
Ω Load).
4. Input -20 dBm/1 kHz to Line I/F.
Measure the level at Receiver of Handset and distortion level
(*Receive volume set to second position from minimum). 
5. Confirm that the level is -20 dBm ± 2 dBm and that the distortion level is < 5%
at Receiver (Volume Middle, 150 
Ω Load).
IC7, CN1, SA1, 
L1, L2, D3, Q3, 
Q4, R14, R15, 
R16, R17
(Q)
Charging Check
-
1. Connect Charge Contact 12 
Ω/2 W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 3.10 V ± 0.2 V.
R55, R56, D23, 
R57, D22
(R)*
TAM Operation 
Confirmation
-
1. TAM Confirmation (Execute the command “sendchar_VPI”)
2. Confirm the returned Value (Value is “DAC7RN 01”).
IC8, IC11, R88, 
C91, R91, R92
Items
Check 
Point
Procedure
Check or 
Replace Parts
(A)
Charging Check
-
1. Connect Charge Contact 12 
Ω/2 W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 3.3 V ± 0.2 V.
R1 
D1, F1
Items
Check 
Point
Procedure
Check or 
Replace Parts
47
KX-TG8227UAB/KX-TG8227UAR/KX-TG8227UAW/KX-TGA820RUB/KX-TGA820RUR/KX-TGA820RUW/KX-TGA820UAB/KX-TGA820UAR/KX-TGA820UAW
9.3.
Troubleshooting by Symptom (Handset)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.  
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Handset) (P.47)
9.3.1.
Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*: Batch file Setting (P.64) is required beforehand.
The connections of adjustment equipments are as shown in Adjustment Standard (Handset) (P.65).
Items
Check 
Point
Procedure
Check or 
Replace Parts
(A)* 1.8 V Supply Adjustment
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command “bandgap”, then check the current value.
3. Adjust the 1.8 V voltage of VDD1 executing command “bandgap XX“(XX is the
value).
IC1, Q2, C10
(B)
DC/DC Supply Confir-
mation
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 4.0 V ± 0.3 V
(Backlight is ON).
IC1, F1, C1, 
C2, C3, R1, 
Q1, D1, L1
(C) 2.5 V Supply Confirma-
tion
VDD2
1. Confirm that the voltage between test point VDD2 and GND is 2.5 V ± 0.1 V.
IC1, Q3, C5
(D)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, X1, C6, 
C7
(E)* EEP-ROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command “ChkTGA820XXrevYY”).
XX: country code
YY: revision number
2. Confirm the returned checksum value.
Note:
“XX”, “YY”, and “checksum” vary depending on the country version. You can find
them in the batch file, PQZZ- mentioned in JIG and PC (P.59).
IC1, IC3,
RA2
(F) Charge Control Check & 
Charge Current Monitor 
Check
-
1. Apply 3.5 V between J3(+) and J4(-) with DC power supply and set current limit
to 250 mA.
2. Confirm that the current limit LED of DC power supply is ON/OFF.
3. Decrease current limit of DC power supply to 100 mA.
4. Confirm that the current limit LED of DC power supply is stable. (Current limiter
is ON.)
(If charge control cannot be confirmed by this procedure, please use battery to hand-
set power supply and try again.)
IC1, Q4, Q5, 
Q9, D7, D8, 
L4, L5, R5, R6, 
R7, F1 
(G)* Charge Detection (OFF) 
Check
-
1. Stop supplying 3.5 V to J3 CHARGE(+) and J4 CHARGE(-).
2. Execute the command “Backloff” then “charge”.
3. Confirm that the returned value is 00 (hex).
IC1, Q4, Q5, 
Q9, D7, D8, 
L4, L5, R5, R6, 
R7, F1 
48
KX-TG8227UAB/KX-TG8227UAR/KX-TG8227UAW/KX-TGA820RUB/KX-TGA820RUR/KX-TGA820RUW/KX-TGA820UAB/KX-TGA820UAR/KX-TGA820UAW
(H)* Battery Monitor Check
-
1. Apply 2.25 V between BATT and GND.
2. Execute the command “readbatt”.
It assumes that the return value is XX.
a) 1E   XX   2C: No need to adjust
b) XX: 18 ~ 1D: Need to adjust
XX: 2D ~ 32: Need to adjust
Write AD value of 2.25V to EEPROM.
ex) read data: XX = 1D, write data: YY = 1D
read data: XX = 2D, write data: YY = 2D
EEPROM = 0004(Low Voltage) write “YY”
Execute the command “wreeprom 00 04 01 YY”.
EEPROM = 0005(No Voltage) write “YY - 1D”
Execute the command “wreeprom 00 05 01 ZZ”.
EEPROM = 000A(Low Voltage BL) write “YY - 16”
Execute the command “wreeprom 00 0A 01 WW”.
Note:
ZZ = YY - 1D, WW = YY - 16
No Voltage writing data limit is ‘00’.
c) XX: 00 ~ 17: Reject
XX: 33 ~ FF: Reject
IC1, F1, C1 
C3, R12
(I)
Battery Low Confirma-
tion
-
1. Apply 2.40 V between BATTERY(+) and BATTERY(-).
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATTERY(+) and BATTERY(-).
4. Confirm that there is flashing of Battery Icon.
IC1, F1, C1 
C3, R12
(J)* BBIC Clock Adjustment
CLK
1. Apply 2.6 V between BATTERY(+) and BATTERY(-) with DC power.
2. Execute the command “conttx”.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz)
Input Command “rdeeprom 00 01 01”, then you can confirm the current value.
4. If the frequency is not 10.368 MHz ± 100Hz, adjust the frequency of CLK exe-
cuting the command “setfreq xx (where xx is the value)” so that the reading of
the frequency counter is 10.368000 MHz ± 10 Hz.
Note:
CLK is displayed only for a few seconds when executing the command “conttx”
after battery is inserted.
IC1, X1, C6, 
C7, IC4, C57 
(K)* Transmitted Power Con-
firmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “regcmd60 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 20 dBm ~ 25 dBm.
IC1, IC4, C58, 
C57, C50, 
C52, C53, 
R52, C60, C61  
(L)* Modulation Check and 
Adjustment
-
Follow steps 1 to 3 of (K).
4.Confirm that the B-Field Modulation is +220 ~ +403/-220 ~ -403 kHz/div & Mod-
ulated width   670 kHz using data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the command “Readmod”
and “wrtmod xx”, where xx is the value.)
IC1, IC4, C58, 
C57, C52, 
C53, R52, 
C61, C59, 
C125, C62 
(M)* Frequency Offset Confir-
mation
-
Follow steps 1 to 3 of (K).
4.Confirm that the frequency Offset is < ± 50 kHz.
IC1, IC4, C58, 
C57, C52, 
C53, R52, 
C61, C59, 
C125, C62  
(N)* Frequency Drift Confir-
mation
-
Follow steps 1 to 3 of (K).
4.Confirm that the frequency Drift is < ± 30 kHz/ms.
IC1, IC4, C58, 
C57, C52, 
C53, R52, 
C61, C59, 
C125, C62
(O)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1, IC4, C58, 
C57, C52, 
C53, R52, 
C61, C59, 
C125, C62
Items
Check 
Point
Procedure
Check or 
Replace Parts
Page of 101