DOWNLOAD Panasonic KX-TG8061RUB / KX-TG8061UAB / KX-TG8061CAB / KX-TGA806RUB Service Manual ↓ Size: 3.48 MB | Pages: 91 in PDF or view online for FREE

Model
KX-TG8061RUB KX-TG8061UAB KX-TG8061CAB KX-TGA806RUB
Pages
91
Size
3.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg8061rub-kx-tg8061uab-kx-tg8061cab-kx-tga806ru.pdf
Date

Panasonic KX-TG8061RUB / KX-TG8061UAB / KX-TG8061CAB / KX-TGA806RUB Service Manual ▷ View online

45
KX-TG8061RUB/KX-TG8061UAB/KX-TG8061CAB/KX-TGA806RUB
Ԝ
Remove the 2 screws to
remove the operational P.C. board.  
Operational P.C. board
Ԝ
2 screws
ԛ
Remove the charge case and 2 screws to remove
the operational P.C. board.  
Charge case
ԛ
2 screws
46
KX-TG8061RUB/KX-TG8061UAB/KX-TG8061CAB/KX-TGA806RUB
10.1.2. Handset
Ԙ
Remove the 2 screws.
ԙ
Ԛ
Likewise, open the other
side of the cabinet.
ԛ
Remove the cabinet cover 
by pushing it upward.
Remove the EP cap.
Ԝ
Remove the screw, solders and tape
to remove the main P. C. board.
Main P.C. board
Ԝ
Screw
Cabinet cover 
2 screws
Ԙ
Solders and
Tape
Cabinet body 
Cabinet cover 
Insert a plastic card. 
(Ex. Used SIM card etc.)  
between the cabinet body 
and the cabinet cover, then 
pull it along the gap to open 
the cabinet.
Ԝ
47
KX-TG8061RUB/KX-TG8061UAB/KX-TG8061CAB/KX-TGA806RUB
10.1.3. Charger Unit
Ԙ
Remove the screw to remove
the cabinet cover.
ԙ
Remove the solders to remove
the 2 charge terminals.
Ԙ
Screw
ԙ
Solders
Main P.C. board
2 charge terminals
48
KX-TG8061RUB/KX-TG8061UAB/KX-TG8061CAB/KX-TGA806RUB
10.2. How to Replace the Base Unit LCD
Ԙ
ԙ
Fit the heatseal of a new LCD.
Rubber of Soldering Iron
(Part No. PQZZ430PRB)
Tip of Soldering Iron
(Part No. PQZZ430PIR)
Heatweld with the tip of the soldering 
iron about 5 to 8 seconds 
(in case of 60W soldering iron).
Operational P.C.B.
0.2mm
0.2mm
If interval tolerance between center lines
is less than 0.2 mm, it is o.k.
Horizontal Interval
Tolerance
Vertical Interval
Tolerance
OK
NG
NG
NG
(Horizontal interval tolerance is
 more than 0.2 mm.)
(Vertical interval tolerance is
 more than 0.2 mm.)
(Inclined)
New LCD
Page of 91
Display

Click on the first or last page to see other KX-TG8061RUB / KX-TG8061UAB / KX-TG8061CAB / KX-TGA806RUB service manuals if exist.