57
KX-TG6811CAB/KX-TG6811CAM/KX-TG6812CAB/KX-TG6821CAB/KX-TG6821CAM/KX-TG6822CAB/KX-TGA681RUB/KX-TGA681RUM
11.5. Adjustment Standard (Handset)
When connecting the simulator equipment for checking, please refer to below.
11.5.1. Component View
Note:
(A) - (Ris referred to Check Point (Handset) (P.41)
+
+
+
R48
ANT- Short
ANT- Short- GND
C91
LCD_OTP
RECEIVER
C38
C81
D21
C70
C71
D22
D14
D13
C73
C72
SP-PHONE_SPEAKER
C92
LCD_SID
LCD_CD
LCD_SCL
%LCD_RESET%
%LCD_CS%
C93
C801
ANT1_TP
JTAG
IC1
IC3
C69
CP2.8V
RA5
R60
C44
R61
C45
C46
C860
C861
C859
C862
R20
C47
C43
C12
R23
RA7
C13
C11
C22 C36
C191
C190
C98 C99
C59
C29
C30
D3
C51
C53
C52
C55
C56
C40
STM
X1
IC4
CP4V
CP3V
CKM
STB_E
KIN_4
KIN_2
SFK_LED
KIN_3
CHG_MON
1.8V
R41
C41
R77
C78
R15
R76
C79
R1
Q1
RA2
Q6 RA3
KEY_LED
C1
C32
R19
R18
C866
C85
KIN_1
STB_D
POWER
STB_B
STB_C
Q10
R10
Q12
R11
Q11
R12
R13
Q9
Q4
CHG_CTRL
STB_A
Q2
C19
R2
R9
R8
Q3
C6
F1
BATT+
R6
R45
C15
UTX
GND
URX
VBAT
BATT-
R7
C5
R3
CHG
CHG
PbF
PNLB2160Z
GREEN
ORANGE
BLUE
ORANGE
A
AF
Generator
MIC-
MIC+
+
+
(N)
CMD T
ester
CMD60
(I)(J)(K)(L)
(M)
D
C
 Po
w
e
r
2.30 - 2.60 V
Connect betw
een 
AN
T
-Shor
t and 
AN
T
-Shor
t GND
.
2.7V Zener
DC P
o
w
e
r
5.0V
CHG+
CHG-
(D)
(E)
F
requency
Counter
U-AR
T
22pF
100
(H)
(A)
(B)(C)(F)
(H)(I)
RX
TX
GND
PC
GND
DC PO
WER
2.00 - 2.25 V
(at batter
y lo
w)
P
o
w
e
r k
e
y
(F)
(G)
VDD
1.8V
(A)
CP3V (P)
CP2.8V (R)
Blue
Oscilloscope
AF V
olt
 Meter
34
8
56
1
F
56
(N)
(O)
Orange
Green
Or
ange
CP4V (Q)
58
KX-TG6811CAB/KX-TG6811CAM/KX-TG6812CAB/KX-TG6821CAB/KX-TG6821CAM/KX-TG6822CAB/KX-TGA681RUB/KX-TGA681RUM
11.6. Things to Do after Replacing IC or X'tal
If repairing or replacing BBIC (FLASH type), EEPROM and X'tal, it is necessary to download the required data such as
Programming data or adjustment data, etc in memory.
The set doesn't operate if it is not executed.
11.6.1. How to download the data
11.6.1.1. Base Unit
First, operate the PC setting according to The Setting Method of JIG (Base Unit)(P.52).
Then download the appropriate data according to the following procedures.
Note:
(*1) WW: destination code, XXX_YYY: revision number
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Base Unit)
 (P.52).
(*2) Refer to Check Point (Base Unit) (P.39)
Items
How to download/Required adjustment
EEPROM (IC611)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “AA” to download 
the data.
2) Default batch file: Execute the command “default.bat”.
3) Country version batch file: Execute the command 
“TG6811EU_WW_RevXXX_YYY.bat” (KX-TG6811) or 
“TG6821EU_WW_RevXXX_YYY.bat” (KX-TG6821) (*1)
4) Clock adjustment: Refer to Check Point (E). (*2)
X'tal (X501)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Apply 5.5V between DCP ad DCM with DC power.
2) Input Command "sendchar sfr", then you can confirm the
current value.
3) Check X'tal Frequency.(13.824 MHz ± 100 Hz).
4) If the frequency is not 13.824 MHz ± 100 Hz, adjust the 
frequency of CKM executing the command "sendchar sfr xx xx
(where xx is the value)" so that the reding of the frequency
counter is 13.824000 MHz ± 7 Hz. 
59
KX-TG6811CAB/KX-TG6811CAM/KX-TG6812CAB/KX-TG6821CAB/KX-TG6821CAM/KX-TG6822CAB/KX-TGA681RUB/KX-TGA681RUM
11.6.1.2. Handset
First, operate the PC setting according to The Setting Method of JIG (Handset)(P.55).
Then download the appropriate data according to the following procedures.
Note:
(*3) WW: destination code, XXX_YYY: revision number
“XXX_YYY” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Handset)
 (P.55)
.
(*4) Refer to Check Point (Handset) (P.41)
Items
How to download/Required adjustment
FLASH(IC4)
Programming data is stored in memory.
1) Make sure to connect the JIG cable, then disconnect the DC
Power in order to download the data.
2) Execute the command “flw441 *********.hex”.
3) Connect the DC Power.
4) Press and hold the handset Power key.
5) While holding down the handset Power key, press the PC
Enter key once.
6) After a few minutes, “Successful upgrade” is displayed  on
the PC indicating downloading has finished.
7) Detach the JIG cable, then press the handset Power key to
turn it on.
8) Connect the JIG cable again, and execute the command
"getchk”, then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
9) Default batch file: Execute the command “default.bat”.
10) Default batch file (remaining): Execute the command
“TGA681RU_DEF_RevXXX_YYY.bat”. (*3).
11) Country version batch file: Execute the command
“TGA681RU_WW_RevXXX_YYY.bat”. (*3).
12) Clock adjustment: Refer to Check Point (H). (*4).
13) 1.8 V setting and battery low detection: Refer to Check
Point (A), (F) and (G). (*4).
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “22” to download 
the data.
2) Default batch file: Execute the command “default.bat”.
3) Default batch file (remaining): Execute the command 
“TGA681RU_DEF_RevXXX_YYY.bat”. (*3)
4) Country version batch file: Execute the command 
“TGA681RU_WW_RevXXX_YYY.bat”. (*3)
5) Clock adjustment: Refer to Check Point (H). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point 
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)
60
KX-TG6811CAB/KX-TG6811CAM/KX-TG6812CAB/KX-TG6821CAB/KX-TG6821CAM/KX-TG6822CAB/KX-TGA681RUB/KX-TGA681RUM
11.7. RF Specification
11.7.1. Base Unit
*: Refer to Check Point (Base Unit) (P.39)
11.7.2. Handset
**: Refer to Check Point (Handset) (P.41)
Item
Value
Refer to -. *
TX Power
18.5 dBm ~ 25 dBm
Check Point (Base Unit) (H)
Modulation
-350 ± 50/+350 ± 50 kHz/div
Check Point (Base Unit) (I)
Frequency Offset
±20 kHz
Check Point (Base Unit) (J)
RX Sensitivity
< 1000 ppm
Check Point (Base Unit) (K)
Power RAMP
Power RAMP is matching
Check Point (Base Unit) (L)
Item
Value
Refer to -. **
TX Power
19 dBm ~ 25 dBm
Check Point (Handset) (I)
Modulation
-350 ± 50/+350 ± 50 kHz/div 
Check Point (Handset) (J)
Frequency Offset
±20 kHz
Check Point (Handset) (K)
RX Sensitivity
< 1000 ppm
Check Point (Handset) (L)
Power RAMP
Power RAMP is matching
Check Point (Handset) (M)
Page of 95
Display