KX-TG6541RUB/KX-TGA651RUB/KX-TGA405RUB
9.1.4.5.
TEST RANGE Check (Range Extender)
CHART1: Setting of TX Power and RX Sensitivity in Range Confirmation TX TEST, RX TEST
Note:
Refer to Commands (P.55)
Item
RE (Range Extender) Check
Range Confirmation TX TEST
(TX Power check)
HS, setting
Checked unit: Low TX power (*1)
Regular unit: High TX power (*1)
1. Register Regular HS and RE (to be checked) to Regular BU.
2. HS is power ON with “1“, “6“and “#“.
3. Set TX Power of the RE and the Regular HS according to CHART1.
4. At distance of about 20m between HS and RE,
Link OK = TX Power of the RE is OK.
No Link = TX Power of the RE is NG.
Range Confirmation RX TEST
(RX sensitivity check)
HS, BU setting
Checked unit: High TX power (*1)
Regular unit: Low TX power (*1)
1. Register Regular HS and RE (to be checked) to Regular BU.
2. HS is power ON with “1“, “6“and “#“.
3. Set TX Power of the RE and the Regular HS according to CHART1.
4. At distance of about 15cm between BU and RE,
5. At distance of about 20m between HS and RE,
Link OK= RX Sensitivity of the RE is OK.
No Link = RX Sensitivity of the RE is NG.
RE (to be checked)
TX Power
RE(Range Extender) TX Power Check
Low
RE(Range Extender) RX Sensitivity Check
High
38
KX-TG6541RUB/KX-TGA651RUB/KX-TGA405RUB
9.1.5.
Check Handset Transmission
Cross Reference:
Signal Route (P.17)
9.1.6.
Check Handset Reception
Cross Reference:
How to Check the Handset Speaker or Receiver (P.67).
Signal Route (P.17)
9.1.7.
Check Caller ID
Cross Reference:
Signal Route (P.17)
39
KX-TG6541RUB/KX-TGA651RUB/KX-TGA405RUB
9.1.8.
Bell Reception
9.1.8.1.
Base Unit
9.1.8.2.
Handset
Cross Reference:
Telephone Line Interface (P.10)
Check Link (P.30)
How to Check the Handset Speaker or Receiver (P.67)
9.1.9.
Check TAM Operation
Cross Reference:
Power Supply Circuit (P.9)
Note:
(*1) When replacing FLASH MEMORY (IC421), TAM data need to be written to it. Refer to Base Unit of Things to Do after
Replacing IC or X'tal
 (P.63)
40
KX-TG6541RUB/KX-TGA651RUB/KX-TGA405RUB
9.2.
Troubleshooting by Symptom (Base Unit and Charger Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not. 
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Base Unit) (P.40)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM or FLASH is replaced.
Note:
After the measuring, suck up the solder of TP.
*: The Setting Method of JIG (Base Unit) (P.54) is required beforehand.
The connections of simulator equipment are as shown in Adjustment Standard (Base Unit) (P.56).
Items
Check 
Point
Procedure
Check or 
Replace Parts
(A) 3.0 V Supply Confirma-
tion
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.0 V ± 0.2 V.
IC2, IC3, C32, 
C36, C86, C87, 
C88, R91, R92, 
R93, R95, D10, 
Q10, L3
(B) 1.8 V Supply Confirma-
tion
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command “VDD XX“(XX is the
value).
Q8, C75, C614, 
C61, IC7
(C) Charge Pump
2.5V Supply Confirma-
tion
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 2.5 V -0.1/+0.3
V. 
IC7,C625,C631
(D) Charge Pump
3.0V Supply Confirma-
tion
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3.0 V ± 0.2 V.  IC7,C616,C630
(E)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC7, X1, R77, 
RA80
(F)* EEPROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
SUM” in Software_Version_Table.xls).
IC7, RA402, 
C51, R657, 
IC401
(G)* BBIC Clock Adjustment
CLK
1. Input Command “ sendchar WWD ff 48 IC 8006”
2. Confirm that the voltage between testpoint VDD4 and GND is less than 1.0 V.
3. Input Command “ sendchar sfr”, then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368MHz ± 100Hz, adjust the frequency of CLK exe-
cuting the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
X1, IC7, R430, 
C305
Page of 104