46
KX-TG5521CAB/KX-TGA551RUB
10.1.2. Handset
Ԙ
Remove the 4 screws.
ԙ
Insert a JIG (PQDJ10006Y) 
between the cabinet body 
and the cabinet cover, then 
pull it along the gap to open 
the cabinet.
Ԛ
Likewise, open the other
side of the cabinet.
ԛ
Remove the cabinet cover 
by pushing it upward.
Ԝ
Remove the solders and tape.
ԝ
Remove the screw to remove 
the main P. C. board.
Cabinet cover 
Cabinet body 
Cabinet cover 
4 screws
Ԙ
Main P.C. board
Ԝ
Screw
ԝ
Solders and
Tape
47
KX-TG5521CAB/KX-TGA551RUB
10.1.3. Charger Unit
Screw
Solders
Main P.C. board
Cabinet cover
Remove the screw to remove
the cabinet cover.
Remove the solders to remove
the 2 charge terminals.
2 charge terminals
Screw
Remove the screw to remove
the main P.C. board.
48
KX-TG5521CAB/KX-TGA551RUB
10.2. How to Replace the Handset LCD
Note:
The illustrations are simplified in this page.
They may differ from the actual product.
Peel off the FFC (Flexible Flat Cable) from 
the LCD, in the direction of the arrow. Take 
care to ensure that the foil on the P.C. board 
is not damaged.
Fit the heatseal of a new LCD.
Rubber of Soldering Iron
(Part No. PQZZ430PRB)
Tip of Soldering Iron
(Part No. PQZZ430PIR)
Heatweld with the tip of the soldering 
iron about 5 to 8 seconds 
(in case of 60W soldering iron).
New LCD
0.2 mm
0.2 mm
P. C. board
If interval tolerance between center lines
is less than 0.2 mm, it is o.k.
Horizontal Interval
Tolerance
Vertical Interval
Tolerance
OK
NG
NG
NG
(Horizontal interval tolerance is
 more than 0.2 mm.)
(Vertical interval tolerance is
 more than 0.2 mm.)
(Inclined)
49
KX-TG5521CAB/KX-TGA551RUB
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in 
 Troubleshooting Guide (P.24)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG (Base Unit)
This section explains the PC setting to use command required in Check Point (Base Unit)(P.36).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG5521CA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.2.1. Connections
 Connect the AC adaptor to DC-JACK (base unit).
 Connect the JIG Cable GND (black) to GND.
 Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
1
2
3
Base unit P. C. board
UTX (yellow)
AC adaptor
1
3
2
3
GND (black)
URX (red)
To Serial Port
(COM port 1*)
JIG Cable
PC
GND
UTX
URX
Page of 88