DOWNLOAD Panasonic KX-TG5521CAB / KX-TGA551RUB (serv.man2) Service Manual ↓ Size: 2.92 MB | Pages: 88 in PDF or view online for FREE

Model
KX-TG5521CAB KX-TGA551RUB (serv.man2)
Pages
88
Size
2.92 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS ANSWERING SYSTEM
File
kx-tg5521cab-kx-tga551rub-sm2.pdf
Date

Panasonic KX-TG5521CAB / KX-TGA551RUB (serv.man2) Service Manual ▷ View online

41
KX-TG5521CAB/KX-TGA551RUB
(F)* Battery Monitor Check
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command 
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) 6c   XX   71: No need to adjust
b) XX: 6A ~ 6B: Need to adjust
XX: 72 ~ 74: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0009(Low Voltage) write “YY”
Execute the command “wreeprom 00 09 01 YY”.
EEPROM = 000A(No Voltage) write ‘’YY - 1D’’
Execute the command “×wreeprom 00 0A 01 ZZ”.
Note:
ZZ = YY - 1D
No Voltage writing data limit is ‘00’.
c) XX: 00 ~ 69: Reject
XX: 75 ~ FF: Reject
IC1, F1, C1, 
R45
(G)
Battery Low 
Confirmation
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
IC1, F1, C1, 
R45
(H)* BBIC Clock Adjustment
CLK
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK
executing the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#" clears the registration.
Register to it on Base Unit after measurement. 
IC1, X1, C47
 
(I)*
Transmitted Power 
Confirmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(J)*
Modulation Check
-
Follow steps 1 to 3 of (K).
4.Confirm that the B-Field Modulation is -370±30/ +370±30 kHz/div & Modulated
width   690 kHz using data type Fig 31.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
Items
Check 
Point
Procedure
Check or 
Replace Parts
42
KX-TG5521CAB/KX-TGA551RUB
(K)*
Frequency Offset 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 50 kHz.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(L)*
Frequency Drift 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 35 kHz/ms.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(M)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(N)*
Power RAMP 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(O)
Audio Check and 
Confirmation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm(600
Ω)/1kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -2.5dBm±2 dBm and that the distortion level is <5% at
TEL Line (600
Ω Load).
5. Input -20dBm(600
Ω)/1kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -30.5dBm±2 dBm and that the distortion level is <5%
at Receiver (150
Ω Load).
IC1, C12, C96, 
C97, R215, 
R27, RA4, 
C11, C13, 
R28, D3, D4, 
MIC, R73, R74
(P) SP phone Audio Check 
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -25 dBm(600
Ω)/1KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -11.0 dBm ± 2 dBm and that the distortion level is <
5%. (vol = 3)
IC1, C12, C73, 
D13, D14, 
R73, R74, 
MIC, C11, 
C13, RA4, 
R27, R28, 
C96, C97, 
R215, C72
(Q)
Charge Pump 3.0V 
Supply Confirmation
CP3.0V
1. Confirm that the voltage between testpoint CP3.0V and GND is 3.0V ± 0.3V.
C49, C52~C54
(R)
Charge Pump 4.0V 
Supply Confirmation
CP4.0V
1. Confirm that the voltage between testpoint CP4.0V and GND is 4.0V ± 0.3V.
C50, C51, 
C55
Items
Check 
Point
Procedure
Check or 
Replace Parts
43
KX-TG5521CAB/KX-TGA551RUB
9.3.2.
Troubleshooting for Speakerphone
When the customer’s telephone line corresponds to the following conditions, and the transmission signal of SP-Phone is
interrupted, performing the next set up to a cordless handset will improve it to some extent.
Conditions
1. When customer’s line has less line loss.
ex.) The customer is using optical fiber, ISDN terminal adaptor, or PBX.
In this case, receiving signal is strong and it may affect transmission signal.
2. When the other party is talking from noisy place.
ex.) The other party is using cellular phone. The background noise is very loud.
In this case, the noise from the other party (i.e. surrounding noise) may affect transmission signal.
Setting Method
• Change the handset address of EEPROM (0129) from 00 to 01 by Engineering Mode.
44
KX-TG5521CAB/KX-TGA551RUB
10 Disassembly and Assembly Instructions
10.1. Disassembly Instructions
10.1.1. Base Unit
Ԙ
Remove the 4 screws to remove
the cabinet cover.
ԙ
Remove the tapes and solders.    
 Cabinet cover
Ԙ
4 screws
Tapes and solders
ԙ
Main P.C. board
Ԛ
Remove the parallel wire to remove
the main P.C. board.
Ԛ
Parallel wire
Page of 88
Display

Click on the first or last page to see other KX-TG5521CAB / KX-TGA551RUB (serv.man2) service manuals if exist.